arXiv ScienceSearch

arXiv subjects

P. Lechner

Publications and source records attributed to P. Lechner.

13 recordsLinked to original sources

Silicon drift detectors for the Spectroscopy Focusing Array of eXTP

We present a silicon drift detector (SDD) system for the spectroscopy focusing array (SFA) of the enhanced X-ray timing and polarimetry (eXTP) mission. The SFA focuses on fast timing (time resolution below 10 {\mu}s) and good spectroscopy capabilities (energy resolution better than 180 eV @ 6 keV). The sensor, consisting of 19 hexagonally shaped pixels with a total sensitive area of ${5.05}\, cm^{2}$, is connected to three high time resolution spectroscopy (HTRS) ASICs, allowing a fast readout of the detector signals. The detector works in a Charge- Sensitive Amplifier configuration. We assembled a prototype detector module and present here its mechanical design, describe the used sensor, and report about its performance.

astro-ph.IM

Precision measurement of $^{65}$Zn electron-capture decays with the KDK coincidence setup

$^{65}$Zn is a common calibration source, moreover used as a radioactive tracer in medical and biological studies. In many cases, $\gamma$-spectroscopy is a preferred method of $^{65}$Zn standardization, which relies directly on the branching ratio of $J \pi (^{65}\text{Zn} ) = 5/2^- \rightarrow J \pi (^{65}\text{Cu}) = 5/2^- $ via electron capture (EC*). We measure the relative intensity of this branch to that proceeding directly to the ground state (EC$^0$) using a novel coincidence technique, finding $I_{\text{EC}^0}/I_{\text{EC*}} = 0.9684 \pm 0.0018$. Re-evaluating the decay scheme of $^{65}$Zn by adopting the commonly evaluated branching ratio of $I_{\beta^+}= 1.4271(7)\%$ we obtain $I_{\text{EC*}} = (50.08 \pm 0.06)\%$, and $I_\text{EC^0} = (48.50 \pm 0.06) \%$. The associated 1115 keV gamma intensity agrees with the previously reported NNDC value, and is now accessible with a factor of ~2 increase in precision. Our re-evaluation removes reliance on the deduction of this gamma intensity from numerous measurements, some of which disagree and depend directly on total activity determination. The KDK experimental technique provides a new avenue for verification or updates to the decay scheme of $^{65}$Zn, and is applicable to other isotopes.

nucl-ex

Evidence for ground-state electron capture of $^{40}$K

Potassium-40 is a widespread isotope whose radioactivity impacts estimated geological ages spanning billions of years, nuclear structure theory, and subatomic rare-event searches - including those for dark matter and neutrinoless double-beta decay. The decays of this long-lived isotope must be precisely known for its use as a geochronometer, and to account for its presence in low-background experiments. There are several known decay modes for $^{40}$K, but a predicted electron-capture decay directly to the ground state of argon-40 has never been observed, while theoretical predictions span an order of magnitude. The KDK Collaboration reports on the first observation of this rare decay, obtained using a novel combination of a low-threshold X-ray detector surrounded by a tonne-scale, high-efficiency $\gamma$-ray tagger at Oak Ridge National Laboratory. A blinded analysis reveals a distinctly nonzero ratio of intensities of ground-state electron-captures ($I_{\text{EC}^0}$) over excited-state ones ($I_{\text{EC}^*}$) of $I_{\text{EC}^0} / I_{\text{EC}^*}=0.0095\stackrel{\text{stat}}{\pm}0.0022\stackrel{\text{sys}}{\pm}0.0010$ (68% CL), with the null hypothesis rejected at 4$\sigma$ [Stukel et al., DOI:10.1103/PhysRevLett.131.052503]. This unambiguous signal yields a branching ratio of $I_{\text{EC}^0}=0.098\%\stackrel{\text{stat}}{\pm}0.023\%\stackrel{\text{sys}}{\pm}0.010$, roughly half of the commonly used prediction. This first observation of a third-forbidden unique electron capture improves understanding of low-energy backgrounds in dark-matter searches and has implications for nuclear-structure calculations. A shell-model based theoretical estimate for the $0\nu\beta\beta$ decay half-life of calcium-48 is increased by a factor of $7^{+3}_{-2}$. Our nonzero measurement shifts geochronological ages by up to a percent; implications are illustrated for Earth and solar system chronologies.

nucl-ex

Rare $^{40}$K decay with implications for fundamental physics and geochronology

Potassium-40 is a widespread, naturally occurring isotope whose radioactivity impacts subatomic rare-event searches, nuclear structure theory, and estimated geological ages. A predicted electron-capture decay directly to the ground state of argon-40 has never been observed. The KDK (potassium decay) collaboration reports strong evidence of this rare decay mode. A blinded analysis reveals a non-zero ratio of intensities of ground-state electron-captures ($I_{\text{EC}^0}$) over excited-state ones ($I_\text{EC*}$) of $ I_{\text{EC}^0} / I_\text{EC*} = 0.0095 \stackrel{\text{stat}}{\pm} 0.0022 \stackrel{\text{sys}}{\pm} 0.0010 $ (68% C.L.), with the null hypothesis rejected at 4$\sigma$. In terms of branching ratio, this signal yields $I_{\text{EC}^0} = 0.098\% \stackrel{\text{stat}}{\pm} 0.023\% \stackrel{\text{sys}}{\pm} 0.010\% $, roughly half of the commonly used prediction, with consequences for various fields [L. Hariasz et al., companion paper, DOI: 10.1103/PhysRevC.108.014327].

nucl-ex

KATRIN: Status and Prospects for the Neutrino Mass and Beyond

The Karlsruhe Tritium Neutrino (KATRIN) experiment is designed to measure a high-precision integral spectrum of the endpoint region of T2 beta decay, with the primary goal of probing the absolute mass scale of the neutrino. After a first tritium commissioning campaign in 2018, the experiment has been regularly running since 2019, and in its first two measurement campaigns has already achieved a sub-eV sensitivity. After 1000 days of data-taking, KATRIN's design sensitivity is 0.2 eV at the 90% confidence level. In this white paper we describe the current status of KATRIN; explore prospects for measuring the neutrino mass and other physics observables, including sterile neutrinos and other beyond-Standard-Model hypotheses; and discuss research-and-development projects that may further improve the KATRIN sensitivity.

nucl-ex

A novel experimental system for the KDK measurement of the $^{40}$K decay scheme relevant for rare event searches

Potassium-40 ($^{40}$K) is a long-lived, naturally occurring radioactive isotope. The decay products are prominent backgrounds for many rare event searches, including those involving NaI-based scintillators. $^{40}$K also plays a role in geochronological dating techniques. The branching ratio of the electron capture directly to the ground state of argon-40 has never been measured, which can cause difficulty in interpreting certain results or can lead to lack of precision depending on the field and analysis technique. The KDK (Potassium (K) Decay (DK)) collaboration is measuring this decay. A composite method has a silicon drift detector with an enriched, thermally deposited $^{40}$K source inside the Modular Total Absorption Spectrometer. This setup has been characterized in terms of energy calibration, gamma tagging efficiency, live time and false negatives and positives. A complementary, homogeneous, method is also discussed; it employs a KSr$_2$I$_5$:Eu scintillator as source and detector.

physics.ins-det

Characterization of Silicon Drift Detectors with Electrons for the TRISTAN Project

Sterile neutrinos are a minimal extension of the Standard Model of Particle Physics. A promising model-independent way to search for sterile neutrinos is via high-precision beta spectroscopy. The Karlsruhe Tritium Neutrino (KATRIN) experiment, equipped with a novel multi-pixel silicon drift detector focal plane array and read-out system, named the TRISTAN detector, has the potential to supersede the sensitivity of previous laboratory-based searches. In this work we present the characterization of the first silicon drift detector prototypes with electrons and we investigate the impact of uncertainties of the detector's response to electrons on the final sterile neutrino sensitivity.

physics.ins-det

The KDK (potassium decay) experiment

Potassium-40 (${}^{40}$K) is a background in many rare-event searches and may well play a role in interpreting results from the DAMA dark-matter search. The electron-capture decay of ${}^{40}$K to the ground state of ${}^{40}$Ar has never been measured and contributes an unknown amount of background. The KDK (potassium decay) collaboration will measure this branching ratio using a ${}^{40}$K source, an X-ray detector, and the Modular Total Absorption Spectrometer at Oak Ridge National Laboratory.

nucl-ex

New Results on DEPFET Pixel Detectors for Radiation Imaging and High Energy Particle Detection

DEPFET pixel detectors are unique devices in terms of energy and spatial resolution because very low noise (ENC = 2.2e at room temperature) operation can be obtained by implementing the amplifying transistor in the pixel cell itself. Full DEPFET pixel matrices have been built and operated for autoradiographical imaging with imaging resolutions of 4.3 +- 0.8 um at 22 keV. For applications in low energy X-ray astronomy the high energy resolution of DEPFET detectors is attractive. For particle physics, DEPFET pixels are interesting as low material detectors with high spatial resolution. For a Linear Collider detector the readout must be very fast. New readout chips have been designed and produced for the development of a DEPFET module for a pixel detector at the proposed TESLA collider (520x4000 pixels) with 50 MHz line rate and 25 kHz frame rate. The circuitry contains current memory cells and current hit scanners for fast pedestal subtraction and sparsified readout. The imaging performance of DEPFET devices as well as present achievements towards a DEPFET vertex detector for a Linear Collider are presented.

physics.ins-det

SIMBOL-X : a new generation hard X-ray telescope

SIMBOL-X is a hard X-ray mission, operating in the 0.5-70 keV range, which is proposed by a consortium of European laboratories for a launch around 2010. Relying on two spacecraft in a formation flying configuration, SIMBOL-X uses a 30 m focal length X-ray mirror to achieve an unprecedented angular resolution (30 arcsec HEW) and sensitivity (100 times better than INTEGRAL below 50 keV) in the hard X-ray range. SIMBOL-X will allow to elucidate fundamental questions in high energy astrophysics, such as the physics of accretion onto Black Holes, of acceleration in quasar jets and in supernovae remnants, or the nature of the hard X-ray diffuse emission. The scientific objectives and the baseline concepts of the mission and hardware design are presented.

astro-ph

Development of Silicon Strip Detectors for a Medium Energy Gamma-ray Telescope

We report on the design, production, and testing of advanced double-sided silicon strip detectors under development at the Max-Planck-Institute as part of the Medium Energy Gamma-ray Astronomy (MEGA) project. The detectors are designed to form a stack, the "tracker," with the goal of recording the paths of energetic electrons produced by Compton-scatter and pair-production interactions. Each layer of the tracker is composed of a 3 x 3 array of 500 micron thick silicon wafers, each 6 cm x 6 cm and fitted with 128 orthogonal p and n strips on opposite sides (470 micron pitch). The strips are biased using the punch-through principle and AC-coupled via metal strips separated from the strip implant by an insulating oxide/nitride layer. The strips from adjacent wafers in the 3 x 3 array are wire-bonded in series and read out by 128-channel TA1.1 ASICs, creating a total 19 cm x 19 cm position-sensitive area. At 20 degrees C a typical energy resolution of 15-20 keV FWHM, a position resolution of 290 microns, and a time resolution of ~1 microsec is observed.

astro-ph

A fast X-ray timing capability on XEUS

Fast X-ray timing can be used to probe strong gravity fields around collapsed objects and constrain the equation of state of dense matter in neutron stars. These studies require extremely good photon statistics. In view of the huge collecting area of its mirrors, XEUS could make a unique contribution to this field. For this reason, we propose to include a fast X-ray timing capability in the focal plane of the XEUS mirrors. We briefly outline the scientific motivation for such a capability. We compute some sensitivity estimates, which indicate that XEUS could provide better than an order of magnitude sensitivity improvement over the Rossi X-ray Timing Explorer. Finally, we present a possible detector implementation, which could be an array of small size silicon drift detectors operated out of focus.

astro-ph

Test Results on the Silicon Pixel Detector for the TTF-FEL Beam Trajectory Monitor

Test measurements on the silicon pixel detector for the beam trajectory monitor at the free electron laser of the TESLA test facility are presented. To determine the electronic noise of detector and read-out and to calibrate the signal amplitude of different pixels the 6 keV photons of the manganese K line are used. Two different methods determine the spatial accuracy of the detector: In one setup a laser beam is focused to a straight line and moved across the pixel structure. In the other the detector is scanned using a low-intensity electron beam of an electron microscope. Both methods show that the symmetry axis of the detector defines a straight line within 0.4 microns. The sensitivity of the detector to low energy X-rays is measured using a vacuum ultraviolet beam at the synchrotron light source HASYLAB. Additionally, the electron microscope is used to study the radiation hardness of the detector.

physics.acc-ph