Morphology and actuation as inductive biases in robotic hand manipulation

Robotic hands vary widely in anatomical fidelity and mechanical complexity, and these structural choices influence the coordination of joint motions and the difficulty of controlling the system. A unified framework is presented in which the kinematic and actuation stages are analysed separately and in composition, through the conditioning of the task Jacobian, the actuation matrix, and their product. It is applied to two hands representing opposing design philosophies, the Shadow Dexterous Hand and the Anatomically Correct, Biomechatronic Hand, along four morphological aspects: joint axis geometry, actuator-to-DOF ratio, coupling architecture, and authority distribution. All parameters are derived from the hands' canonical digital representations. Anatomical fidelity carries no uniform advantage: oblique axes improve thumb conditioning but leave the long fingers worse conditioned than the orthogonal-axis design, while the branching tendon network improves the effective control mapping at every long finger and worsens it significantly at the thumb, where actuator authority is concentrated on thumb opposition. Predictions derived from these metrics are evaluated against reinforcement learning experiments using PPO, DDPG+HER, and TQC+HER, across three different tasks.

cs.RO

Tendon-based modelling, estimation and control for a simulated high-DoF anthropomorphic hand model

Tendon-driven anthropomorphic robotic hands often lack direct joint angle sensing, as the integration of joint encoders can compromise mechanical compactness and dexterity. This paper presents a computational method for estimating joint positions from measured tendon displacements and tensions. An efficient kinematic modeling framework for anthropomorphic hands is first introduced based on the Denavit-Hartenberg convention. Using a simplified tendon model, a system of nonlinear equations relating tendon states to joint positions is derived and solved via a nonlinear optimization approach. The estimated joint angles are then employed for closed-loop control through a Jacobian-based proportional-integral (PI) controller augmented with a feedforward term, enabling gesture tracking without direct joint sensing. The effectiveness and limitations of the proposed estimation and control framework are demonstrated in the MuJoCo simulation environment using the Anatomically Correct Biomechatronic Hand, featuring five degrees of freedom for each long finger and six degrees of freedom for the thumb.

cs.RO