Search for Axion Dark Matter around \texorpdfstring{$15.6\,\mu\text{eV}$}{15.6 microeV} with a Broadly Tunable High-Temperature Superconducting Cavity

We report an axion dark matter search in the mass range of $15.30\text{--}15.85\,\mu\text{eV}$ using a broadly tunable high-temperature superconducting (HTS) haloscope. By soldering substrate-stripped rare-earth barium copper oxide (REBCO) films onto a copper shell, we achieved a quality factor 3--4 times higher than in copper cavities across its tuning band in an 8\text{-T} magnetic field. We set robust Frequentist 90\%~confidence-level exclusion limits on the axion--photon coupling down to 1.3 times the KSVZ coupling, while a complementary Bayesian analysis achieves KSVZ-level sensitivity.

hep-ex

Multi-tesla operation of high-temperature superconducting cavities for accelerated axion dark matter searches

Axion haloscopes use radio-frequency cavities immersed in a magnetic field to search for dark-matter axions, which could resolve two central puzzles in fundamental physics: the strong charge-parity problem in quantum chromodynamics and the nature of dark matter. Multi-tesla fields trigger axion-to-photon conversion but induce severe vortex dissipation in standard superconductors, whereas copper cavities are limited by the anomalous skin effect ($Q \lesssim 10^5$). Here, we overcome these barriers by introducing a pole-to-pole 3-dimensional cavity architecture constructed from strain-controlled, mechanically delaminated rare-earth barium copper oxide (REBCO) tapes. By selectively stripping the lossy metallic substrate while utilizing the copper stabilizer as a "conductive backing" we convert the longitudinal assembly gaps into waveguides below cutoff, effectively suppressing cross-seam RF leakage. Employing a two-track strategy, we first unveiled the intrinsic high-field potential of the material with a 5.4 GHz resonant cavity, achieving an unloaded quality-factor ($Q_0$) of $1.4 \times 10^7$ in an 8 T magnetic field, exceeding conventional copper baselines by two orders of magnitude. Second, prioritizing practical haloscope integration, we engineered a tunable, volume-maximized 2.3 GHz pathfinder cavity. Deployed in the Pilot Axion Cavity Experiment at the Center for Axion and Precision Physics Research (CAPP-PACE), this system achieved a 180 mK noise temperature and a 5-fold $Q$ enhancement over copper, cumulatively delivering a $\sim$8.4-fold scan-rate acceleration.

hep-ex

Extended Haloscope Search and Exclusion of a Candidate Signal near 1.036 GHz

We report a follow-up axion haloscope search near 1.036 GHz that completes and extends our previous work [Phys. Rev. X 14, 031023 (2024)], in which a portion of the HEMT-based data could not be analyzed due to unrecorded experimental information. While recovering this dataset, we identified an excess near 1.036 GHz that satisfied our candidate-selection criteria, motivating dedicated validation studies, including independent cross-checks and re-examination with the original apparatus. The excess did not persist under these investigations and was not confirmed as an axion dark-matter signal. We subsequently extended the search over a 20-MHz band surrounding the candidate using a quantum-noise-limited amplifier, achieving sensitivity close to the Dine-Fischler-Srednicki-Zhitnitsky benchmark. In the absence of a confirmed signal, we set improved 90% confidence-level upper limits on the axion-photon coupling over the frequency range 1.026-1.045 GHz. This work highlights the importance of robust candidate-validation strategies as haloscope searches approach discovery-level sensitivity.

hep-ex

QUPID: Quantified Understanding for Enhanced Performance, Insights, and Decisions in Korean Search Engines

Large language models (LLMs) have been widely used for relevance assessment in information retrieval. However, our study demonstrates that combining two distinct small language models (SLMs) with different architectures can outperform LLMs in this task. Our approach -- QUPID -- integrates a generative SLM with an embedding-based SLM, achieving higher relevance judgment accuracy while reducing computational costs compared to state-of-the-art LLM solutions. This computational efficiency makes QUPID highly scalable for real-world search systems processing millions of queries daily. In experiments across diverse document types, our method demonstrated consistent performance improvements (Cohen's Kappa of 0.646 versus 0.387 for leading LLMs) while offering 60x faster inference times. Furthermore, when integrated into production search pipelines, QUPID improved nDCG@5 scores by 1.9%. These findings underscore how architectural diversity in model combinations can significantly enhance both search relevance and operational efficiency in information retrieval systems.

cs.CL

Zero-Shot Multi-Hop Question Answering via Monte-Carlo Tree Search with Large Language Models

Recent advances in large language models (LLMs) have significantly impacted the domain of multi-hop question answering (MHQA), where systems are required to aggregate information and infer answers from disparate pieces of text. However, the autoregressive nature of LLMs inherently poses a challenge as errors may accumulate if mistakes are made in the intermediate reasoning steps. This paper introduces Monte-Carlo tree search for Zero-shot multi-hop Question Answering (MZQA), a framework based on Monte-Carlo tree search (MCTS) to identify optimal reasoning paths in MHQA tasks, mitigating the error propagation from sequential reasoning processes. Unlike previous works, we propose a zero-shot prompting method, which relies solely on instructions without the support of hand-crafted few-shot examples that typically require domain expertise. We also introduce a behavioral cloning approach (MZQA-BC) trained on self-generated MCTS inference trajectories, achieving an over 10-fold increase in reasoning speed with bare compromise in performance. The efficacy of our method is validated on standard benchmarks such as HotpotQA, 2WikiMultihopQA, and MuSiQue, demonstrating that it outperforms existing frameworks.

cs.CL

SLM as Guardian: Pioneering AI Safety with Small Language Models

Most prior safety research of large language models (LLMs) has focused on enhancing the alignment of LLMs to better suit the safety requirements of humans. However, internalizing such safeguard features into larger models brought challenges of higher training cost and unintended degradation of helpfulness. To overcome such challenges, a modular approach employing a smaller LLM to detect harmful user queries is regarded as a convenient solution in designing LLM-based system with safety requirements. In this paper, we leverage a smaller LLM for both harmful query detection and safeguard response generation. We introduce our safety requirements and the taxonomy of harmfulness categories, and then propose a multi-task learning mechanism fusing the two tasks into a single model. We demonstrate the effectiveness of our approach, providing on par or surpassing harmful query detection and safeguard response performance compared to the publicly available LLMs.

cs.CL

Taxonomy and Analysis of Sensitive User Queries in Generative AI Search

Although there has been a growing interest among industries in integrating generative LLMs into their services, limited experience and scarcity of resources act as a barrier in launching and servicing large-scale LLM-based services. In this paper, we share our experiences in developing and operating generative AI models within a national-scale search engine, with a specific focus on the sensitiveness of user queries. We propose a taxonomy for sensitive search queries, outline our approaches, and present a comprehensive analysis report on sensitive queries from actual users. We believe that our experiences in launching generative AI search systems can contribute to reducing the barrier in building generative LLM-based services.

cs.IR

Extensive search for axion dark matter over 1\,GHz with CAPP's Main Axion eXperiment

We report an extensive high-sensitivity search for axion dark matter above 1\,GHz at the Center for Axion and Precision Physics Research (CAPP). The cavity resonant search, exploiting the coupling between axions and photons, explored the frequency (mass) range of 1.025\,GHz (4.24\,$\mu$eV) to 1.185\,GHz (4.91\,$\mu$eV). We have introduced a number of innovations in this field, demonstrating the practical approach of optimizing all the relevant parameters of axion haloscopes, extending presently available technology. The CAPP 12\,T magnet with an aperture of 320\,mm made of Nb$_3$Sn and NbTi superconductors surrounding a 37-liter ultralight-weight copper cavity is expected to convert DFSZ axions into approximately $10^2$ microwave photons per second. A powerful dilution refrigerator, capable of keeping the core system below 40\,mK, combined with quantum-noise limited readout electronics, achieved a total system noise of about 200\,mK or below, which corresponds to a background of roughly $4\times 10^3$ photons per second within the axion bandwidth. The combination of all those improvements provides unprecedented search performance, imposing the most stringent exclusion limits on axion--photon coupling in this frequency range to date. These results also suggest an experimental capability suitable for highly-sensitive searches for axion dark matter above 1\,GHz.

hep-ex

Search for the Sagittarius Tidal Stream of Axion Dark Matter around 4.55 $\mu$eV

We report the first search for the Sagittarius tidal stream of axion dark matter around 4.55 $\mu$eV using CAPP-12TB haloscope data acquired in March of 2022. Our result excluded the Sagittarius tidal stream of Dine-Fischler-Srednicki-Zhitnitskii and Kim-Shifman-Vainshtein-Zakharov axion dark matter densities of $\rho_a\gtrsim0.184$ and $\gtrsim0.025$ GeV/cm$^{3}$, respectively, over a mass range from 4.51 to 4.59 $\mu$eV at a 90% confidence level.

hep-ex

Axion Dark Matter Search around 4.55 $\mu$eV with Dine-Fischler-Srednicki-Zhitnitskii Sensitivity

We report an axion dark matter search at Dine-Fischler-Srednicki-Zhitnitskii sensitivity with the CAPP-12TB haloscope, assuming axions contribute 100\% of the local dark matter density. The search excluded the axion--photon coupling $g_{a\gamma\gamma}$ down to about $6.2\times10^{-16}$ GeV$^{-1}$ over the axion mass range between 4.51 and 4.59 $\mu$eV at a 90\% confidence level. The achieved experimental sensitivity can also exclude Kim-Shifman-Vainshtein-Zakharov axion dark matter that makes up just 13\% of the local dark matter density. The CAPP-12TB haloscope will continue the search over a wide range of axion masses.

hep-ex

Leveraging Off-the-shelf Diffusion Model for Multi-attribute Fashion Image Manipulation

Fashion attribute editing is a task that aims to convert the semantic attributes of a given fashion image while preserving the irrelevant regions. Previous works typically employ conditional GANs where the generator explicitly learns the target attributes and directly execute the conversion. These approaches, however, are neither scalable nor generic as they operate only with few limited attributes and a separate generator is required for each dataset or attribute set. Inspired by the recent advancement of diffusion models, we explore the classifier-guided diffusion that leverages the off-the-shelf diffusion model pretrained on general visual semantics such as Imagenet. In order to achieve a generic editing pipeline, we pose this as multi-attribute image manipulation task, where the attribute ranges from item category, fabric, pattern to collar and neckline. We empirically show that conventional methods fail in our challenging setting, and study efficient adaptation scheme that involves recently introduced attention-pooling technique to obtain a multi-attribute classifier guidance. Based on this, we present a mask-free fashion attribute editing framework that leverages the classifier logits and the cross-attention map for manipulation. We empirically demonstrate that our framework achieves convincing sample quality and attribute alignments.

cs.CV

Near-Quantum-Noise Axion Dark Matter Search at CAPP around 9.5 $\mu$eV

We report the results of an axion dark matter search over an axion mass range of 9.39-9.51 ${\mu}$eV. A flux-driven Josephson parametric amplifier (JPA) was added to the cryogenic receiver chain. A system noise temperature of as low as 200 mK was achieved, which is the lowest recorded noise among published axion cavity experiments with phase-insensitive JPA operation. In addition, we developed a two-stage scanning method which boosted the scan speed by 26%. As a result, a range of two-photon coupling in a plausible model for the QCD axion was excluded with an order of magnitude higher in sensitivity than existing limits.

hep-ex

First prototype of a biaxially textured YBa$_{2}$Cu$_{3}$O$_{7-x}$ microwave cavity in a high magnetic field for dark matter axion search

A high-quality factor microwave resonator in the presence of a strong magnetic field could have a wide range of applications, such as axion dark matter searches where the two aspects must coexist to enhance the experimental sensitivity. We introduce a polygon-shaped cavity design with bi-axially textured YBa$_{2}$Cu$_{3}$O$_{7-x}$ superconducting tapes covering the entire inner wall. Using a 12-sided polygon cavity, we obtain substantially improved quality factors of the TM$_{010}$ mode at 6.9 GHz at 4 K with respect to a copper cavity and observe no considerable degradation in the presence of magnetic fields up to 8 T. This corresponds to the first demonstration of practical applications of superconducting radio frequency technology for axion and other research areas requiring low loss in a strong magnetic field. We address the importance of the successful demonstration and discuss further improvements.

physics.ins-det

First Results from Axion Haloscope at CAPP around 10.7 $\mu$eV

The Center for Axion and Precision Physics research at the Institute for Basic Science is searching for axion dark matter using ultra-low temperature microwave resonators. We report the exclusion of the axion mass range 10.7126$-$10.7186 $\mu$eV with near Kim-Shifman-Vainshtein-Zakharov (KSVZ) coupling sensitivity and the range 10.16$-$11.37 $\mu$eV with about 9 times larger coupling at 90$\%$ confidence level. This is the first axion search result in these ranges. It is also the first with a resonator physical temperature of less than 40 mK.

hep-ex

Superconducting cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be used in a wide range of applications, especially for enhancing the scanning speed in axion dark matter research. In this letter, we introduce a polygon-shaped resonant cavity with commercial YBCO tapes covering the entire inner wall. We demonstrated that the maximum Q-factor (TM$_{010}$, 6.93 GHz) of the superconducting YBCO cavity was about 6 times higher than that of a copper cavity and showed no significant degradation up to 8 T at 4 K. This is the first indication of the possible applications of HTS technology to the research areas requiring low loss in a strong magnetic field at high radio frequencies.

physics.app-ph

Axion Dark Matter Research with IBS/CAPP

The axion, a consequence of the PQ mechanism, has been considered as the most elegant solution to the strong-CP problem and a compelling candidate for cold dark matter. The Center for Axion and Precision Physics Research (CAPP) of the Institute for Basic Science (IBS) was established on 16 October 2013 with a main objective to launch state of the art axion experiments in South Korea. Relying on the haloscope technique, our strategy is to run several experiments in parallel to explore a wide range of axion masses with sensitivities better than the QCD axion models. We utilize not only the advanced technologies, such as high-field large-volume superconducting (SC) magnets, ultra low temperature dilution refrigerators, and nearly quantum-limited noise amplifiers, but also some unique features solely developed at the Center, including high-quality SC resonant cavities surviving high magnetic fields and efficient cavity geometries to reach high-frequency regions. Our goal is to probe axion dark matter in the frequency range of 1-10 GHz in the first phase and then ultimately up to 25 GHz, even in a scenario where axions constitute only 10% of the local dark matter halo. In this report, the current status and future prospects of the experiments and R&D activities at IBS/CAPP are described.

physics.ins-det

Exploiting higher-order resonant modes for axion haloscopes

The haloscope is one of the most sensitive approaches to the QCD axion physics within the region where the axion is considered to be a dark matter candidate. Current experimental sensitivities, which rely on the lowest fundamental TM010 mode of a cylindrical cavity, are limited to relatively low mass regions. Exploiting higher-order resonant modes would be beneficial because it will enable us to extend the search range with no volume loss and higher quality factors. This approach has been discarded mainly because of the significant degradation of form factor, and difficulty with frequency tuning. Here we introduce a new tuning mechanism concept which both enhances the form factor and yields reasonable frequency tunability. A proof of concept demonstration verified that this design is feasible for high mass axion search experiments.

physics.ins-det

Maintaining high Q-factor of superconducting YBa$_2$Cu$_3$O$_{7-x}$ microwave cavity in a high magnetic field

A high Q-factor microwave resonator in a high magnetic field could be of great use in a wide range of fields, from accelerator design to axion dark matter search. The natural choice of material for the superconducting cavity to be placed in a high field is a high temperature superconductor (HTS) with a high critical field. The deposition, however, of a high-quality, grain-aligned HTS film on a three-dimensional surface is technically challenging. We have fabricated a polygon-shaped resonant cavity with commercial YBa$_2$Cu$_3$O$_{7-x}$ (YBCO) tapes covering the entire inner wall and measured the Q-factor at 4 K at 6.93 GHz as a function of an external DC magnetic field. We demonstrated that the high Q-factor of the superconducting YBCO cavity showed no significant degradation from 1 T up to 8 T. This is the first indication of the possible applications of HTS technology to the research areas requiring a strong magnetic field at high radio frequencies.

physics.ins-det