arXiv ScienceSearch

arXiv subjects

Nils Strodthoff

Publications and source records attributed to Nils Strodthoff.

At least 19 recordsLinked to original sources

Foundation models for movement data: Are they ready for prime-time?

Foundation models (FMs) trained on large-scale accelerometer data have been proposed as general-purpose feature extractors for health monitoring, but systematic evidence of their advantages is lacking. We present the first comprehensive evaluation of four open-source accelerometer FMs against supervised baselines covering 19 tasks across the domains of activity recognition including activities of daily living, clinical monitoring, and physiological inference. We find task-dependent performance results: supervised models remain competitive with FMs on human action recognition (HAR), with no consistent advantage for either, while selected FMs lead on fall and stress detection and are the most robust to sensor-placement variation. As frozen feature extractors, FMs are strongest for demographic inference, whereas sleep staging performance remains near chance level for all models. The internal FM representations show strong similarity across layers, highlighting potential for future FM improvements. Linear and frozen probing reveals that UniMTS provides the strongest representations and is the only FM that surpasses the supervised baselines without finetuning. Concept discovery analysis shows all models capture high-intensity activities clearly but struggle with sedentary, complex or ambiguous activities. We provide scenario-based deployment recommendations. Furthermore, we identify FM-derived activity profile inference-moving beyond fixed category classification-as a promising research direction.

eess.SP

Foundation Models vs. Radiomics for Lung Computed Tomography: A Benchmark of Feature Extractors, Classification Heads, and Segmentation Choices

Radiomics is the established approach for CT-based lung cancer phenotyping, yet comparisons with foundation models rarely isolate contributions of feature extractor, classification head, and segmentation choice, or test cross-cohort robustness. We benchmark five feature extractors (Curia, Curia-2, DINOv3, Radiomics2D, Radiomics3D), seven classification heads (TabPFN, TabICL, XGBoost, CatBoost, Random Forest, logistic regression, Ridge), and three segmentation regimes on five tasks: tumor volume and stage classification, 2-year survival prediction, histology classification, and age prediction. Models are trained on LUNG1 (n=338) and evaluated on an internal test set (n=84) and the external LUNG2 cohort (n=211), with worst-case cross-cohort performance as the primary metric. The dominant design factor is task-dependent: segmentation drives volume and stage classification, while classifier choice drives survival, histology, and age prediction. Radiomics is competitive for tumor volume, tumor stage and survival (partly due to label-derivation effects for the former); Curia variants reach comparable peak scores for survival; DINOv3 falls slightly short across tasks. Patch and slice aggregation have negligible impact. We recommend Curia with tumor segmentation and a CatBoost head as a safe default, achieving the best mean rank across the three primary clinical tasks, though task-specific selection consistently outperforms any cross-task default. When tumor delineations are unavailable, Curia-2 with lung segmentation and logistic regression offers a competitive alternative. All pipelines use a two-stage design suited to small cohort sizes where end-to-end fine-tuning would risk overfitting.

cs.CV

Uncertainty Reliability Under Domain Shift: An Investigation for Data-Driven Blood Pressure Estimation in Photoplethysmography

Uncertainty quantification (UQ) is critical for safety-critical domains like healthcare, yet it is rarely evaluated under realistic out-of-distribution (OOD) conditions. Here, we assessed predictive performance and uncertainty reliability for deep learning-based blood pressure (BP) estimation from photoplethysmography (PPG) signals under both in-distribution (ID) and OOD settings. Using an XResNet1D-50 trained on PulseDB and tested on four external datasets, we compared deep ensembles (DE) and Monte Carlo dropout (MCD) with Gaussian negative log-likelihood (GNLL) and mean squared error (MSE) losses, optionally followed by post-hoc recalibration via conformal prediction (CP), temperature scaling (TS), and isotonic regression (IR). The key findings of our study are as follows: (1) DE provides stronger predictive robustness under domain shift than MCD, an advantage that becomes clear primarily under external shift. (2) Recalibrated GNLL-based methods yield the best uncertainty calibration (e.g., GNLL+DE+CP for systolic blood pressure (SBP), GNLL+DE+TS for diastolic blood pressure (DBP)), while MSE-based uncertainty requires recalibration to become practically useful. (3) Across settings, CP and TS offer the most consistent gains, with IR remaining competitive in several cases. Overall, our results identify DE-based methods as most robust for predictive performance under domain shift, GNLL as strongest for native UQ, and recalibration as essential for making MSE-based uncertainty practical. These findings highlight the need to jointly assess predictive accuracy and calibration on external data for trustworthy cuffless BP estimation

cs.LG

Pretraining Strategies and Scaling for ECG Foundation Models: A Systematic Study

Specialized foundation models are beginning to emerge in various medical subdomains, but pretraining methodologies and parametric scaling with the size of the pretraining dataset are rarely assessed systematically and in a like-for-like manner. This work focuses on foundation models for electrocardiography (ECG) data, one of the most widely captured physiological time series world-wide. We present a comprehensive assessment of pretraining methodologies, covering five different contrastive and non-contrastive self-supervised learning objectives for ECG foundation models, and investigate their scaling behavior with pretraining dataset sizes up to 11M input samples, exclusively from publicly available sources. Pretraining strategy has a meaningful and consistent impact on downstream performance, with contrastive predictive coding (slightly ahead of JEPA) yielding the most transferable representations across diverse clinical tasks. Scaling pretraining data continues to yield meaningful improvements up to 11M samples for most objectives. We also compare model architectures across all pretraining methodologies and find evidence for a clear superiority of structured state space models compared to transformers and CNN models. We hypothesize that the strong inductive biases of structured state space models, rather than pretraining scale alone, are the primary driver of effective ECG representation learning, with important implications for future foundation model development in this and potentially other physiological signal domains.

eess.SP

FeatMap: Understanding image manipulation in the feature space and its implications for feature space geometry

Intermediate feature representations represent the backbone for the expressivity and adaptability of deep neural networks. However, their geometric structure remains poorly understood. In this submission, we provide indirect insights into this matter by applying a broad selection of manipulations in input space, ranging from geometric and photometric transformations to local masking and semantic manipulations using generative image editing models, and assess the feasibility of learning a mapping in the feature space, mapping from the original to the manipulated feature map. To this end, we devise different types of mappings, from linear to non-linear and local to global mappings and assess both the reconstruction quality of the mapping as well as the semantic content of the mapped representations. We demonstrate the feasibility of learning such mappings for all considered transformations. While global (transformer) models that operate on the full feature map often achieve best results, we show that the same can be achieved with a shared linear model operating on a single feature vector typically with very little degradation in reconstruction quality, even for highly non-trivial semantic manipulations. We analyze the corresponding mappings across different feature layers and characterize them according to dominance of weight vs. bias and the effective rank of the linear transformations. These results provide hints for the hypothesis that the feature space is to a first degree of approximation organized in linear structures. From a broader perspective, the study demonstrates that generative image editing models might open the door to a deeper understanding of the feature space through input manipulation.

cs.LG

Benchmark Problems and Benchmark Datasets for the evaluation of Machine and Deep Learning methods on Photoplethysmography signals: the D4 report from the QUMPHY project

This report is part of the Qumphy project (22HLT01 Qumphy) that is funded by the European Union and is dedicated to the development of measures to quantify the uncertainties associated with Machine Learning algorithms applied to medical problems, in particular the analysis and processing of Photoplethysmography (PPG) signals. In this report, a list of six medical problems that are related to PPG signals and serve as Benchmark Problems is given. Suitable Benchmark datasets and their usage are described also.

cs.LG

Deriving Health Metrics from the Photoplethysmogram: Benchmarks and Insights from MIMIC-III-Ext-PPG

Photoplethysmography (PPG) is one of the most widely captured biosignals for clinical prediction tasks, yet PPG-based algorithms are typically trained on small-scale datasets of uncertain quality, which hinders meaningful algorithm comparisons. We present a comprehensive benchmark for PPG-based clinical prediction using the \dbname~dataset, establishing baselines across the full spectrum of clinically relevant applications: multi-class heart rhythm classification, and regression of physiological parameters including respiratory rate (RR), heart rate (HR), and blood pressure (BP). Most notably, we provide the first comprehensive assessment of PPG for general arrhythmia detection beyond atrial fibrillation (AF) and atrial flutter (AFLT), with performance stratified by BP, HR, and demographic subgroups. Using established deep learning architectures, we achieved strong performance for AF detection (AUROC = 0.96) and accurate physiological parameter estimation (RR MAE: 2.97 bpm; HR MAE: 1.13 bpm; SBP/DBP MAE: 16.13/8.70 mmHg). Cross-dataset validation demonstrates excellent generalizability for AF detection (AUROC = 0.97), while clinical subgroup analysis reveals marked performance differences across subgroups by BP, HR, and demographic strata. These variations appear to reflect population-specific waveform differences rather than systematic bias in model behavior. This framework establishes the first integrated benchmark for multi-task PPG-based clinical prediction, demonstrating that PPG signals can effectively support multiple simultaneous monitoring tasks and providing essential baselines for future algorithm development.

cs.LG

Towards Objective Gastrointestinal Auscultation: Automated Segmentation and Annotation of Bowel Sound Patterns

Bowel sounds (BS) are typically momentary and have low amplitude, making them difficult to detect accurately through manual auscultation. This leads to significant variability in clinical assessment. Digital acoustic sensors allow the acquisition of high-quality BS and enable automated signal analysis, offering the potential to provide clinicians with both objective and quantitative feedback on bowel activity. This study presents an automated pipeline for bowel sound segmentation and classification using a wearable acoustic SonicGuard sensor. BS signals from 83 subjects were recorded using a SonicGuard sensor. Data from 40 subjects were manually annotated by clinical experts and used to train an automatic annotation algorithm, while the remaining subjects were used for further model evaluation. An energy-based event detection algorithm was developed to detect BS events. Detected sound segments were then classified into BS patterns using a pretrained Audio Spectrogram Transformer (AST) model. Model performance was evaluated separately for healthy individuals and patients. The best configuration used two specialized models, one trained on healthy subjects and one on patients, achieving (accuracy: 0.97, AUROC: 0.98) for healthy group and (accuracy: 0.96, AUROC: 0.98) for patient group. The auto-annotation method reduced manual labeling time by approximately 70%, and expert review showed that less than 12% of automatically detected segments required correction. The proposed automated segmentation and classification system enables quantitative assessment of bowel activity, providing clinicians with an objective diagnostic tool that may improve the diagnostic of gastrointestinal function and support the annotation of large-scale datasets.

cs.SD

Benchmarking ECG FMs: A Reality Check Across Clinical Tasks

The 12-lead electrocardiogram (ECG) is a long-standing diagnostic tool. Yet machine learning for ECG interpretation remains fragmented, often limited to narrow tasks or datasets. FMs promise broader adaptability, but fundamental questions remain: Which architectures generalize best? How do models scale with limited labels? What explains performance differences across model families? We benchmarked eight ECG FMs on 26 clinically relevant tasks using 12 public datasets comprising 1,650 regression and classification targets. Models were evaluated under fine-tuning and frozen settings, with scaling analyses across dataset sizes. Results show heterogeneous performance across domains: in adult ECG interpretation, three FMs consistently outperformed strong supervised baselines. In contrast, ECG-CPC, a compact structured state-space model, dominated 5 of 7 task categories, demonstrating that architecture matters more than scale. FMs improved label efficiency 3.3-9x over supervised baselines, though scaling behaviors varied across architectures. Representation analysis reveals that models with similar performance learn markedly different internal structures, suggesting multiple viable paths to effective ECG representation. Overall, while FMs show promise for adult ECG analysis, substantial gaps remain in cardiac structure, outcome prediction, and patient characterization. ECG-CPC's strong performance despite being orders of magnitude smaller challenges the assumption that FM quality requires massive scale, highlighting architectural inductive biases as an untapped opportunity.

eess.SP

Machine-learning for photoplethysmography analysis: Benchmarking feature, image, and signal-based approaches

Photoplethysmography (PPG) is a widely used non-invasive physiological sensing technique, suitable for various clinical applications. Such clinical applications are increasingly supported by machine learning methods, raising the question of the most appropriate input representation and model choice. Comprehensive comparisons, in particular across different input representations, are scarce. We address this gap in the research landscape by a comprehensive benchmarking study covering three kinds of input representations, interpretable features, image representations and raw waveforms, across prototypical regression and classification use cases: blood pressure and atrial fibrillation prediction. In both cases, the best results are achieved by deep neural networks operating on raw time series as input representations. Within this model class, best results are achieved by modern convolutional neural networks (CNNs). but depending on the task setup, shallow CNNs are often also very competitive. We envision that these results will be insightful for researchers to guide their choice on machine learning tasks for PPG data, even beyond the use cases presented in this work.

cs.LG

Generalizable deep learning for photoplethysmography-based blood pressure estimation -- A Benchmarking Study

Photoplethysmography (PPG)-based blood pressure (BP) estimation represents a promising alternative to cuff-based BP measurements. Recently, an increasing number of deep learning models have been proposed to infer BP from the raw PPG waveform. However, these models have been predominantly evaluated on in-distribution test sets, which immediately raises the question of the generalizability of these models to external datasets. To investigate this question, we trained five deep learning models on the recently released PulseDB dataset, provided in-distribution benchmarking results on this dataset, and then assessed out-of-distribution performance on several external datasets. The best model (XResNet1d101) achieved in-distribution MAEs of 9.4 and 6.0 mmHg for systolic and diastolic BP respectively on PulseDB (with subject-specific calibration), and 14.0 and 8.5 mmHg respectively without calibration. Equivalent MAEs on external test datasets without calibration ranged from 15.0 to 25.1 mmHg (SBP) and 7.0 to 10.4 mmHg (DBP). Our results indicate that the performance is strongly influenced by the differences in BP distributions between datasets. We investigated a simple way of improving performance through sample-based domain adaptation and put forward recommendations for training models with good generalization properties. With this work, we hope to educate more researchers for the importance and challenges of out-of-distribution generalization.

cs.LG

Multi-Window Temporal Analysis for Enhanced Arrhythmia Classification: Leveraging Long-Range Dependencies in Electrocardiogram Signals

Objective. Arrhythmia classification from electrocardiograms (ECGs) suffers from high false positive rates and limited cross-dataset generalization, particularly for atrial fibrillation (AF) detection where specificity ranges from 0.72 to 0.98 using conventional 30-s analysis windows. While most deep learning approaches analyze isolated 30-s ECG windows, many arrhythmias, including AF and atrial flutter, exhibit diagnostic features that emerge over extended time scales. Approach. We introduce S4ECG, a deep learning architecture based on structured state-space models (S4), designed to capture long-range temporal dependencies by jointly analyzing multiple consecutive ECG windows spanning up to 20 min. We evaluate S4ECG on four publicly available databases for multi-class arrhythmia classification and perform systematic cross-dataset evaluations to assess out-of-distribution robustness. Results. Multi-window analysis consistently outperforms single-window approaches across all datasets, improving macro-averaged AUROC by 1.0-11.6 percentage points. For AF, specificity increases from 0.718-0.979 to 0.967-0.998 at a fixed sensitivity threshold, yielding a 3-10-fold reduction in false positive rates. Significance. Compared with convolutional neural network baselines, the S4 architecture shows superior performance, and multi-window training substantially reduces cross-dataset degradation. Optimal diagnostic windows are 10-20 min, beyond which performance plateaus or degrades. These findings demonstrate that structured incorporation of extended temporal context enhances both arrhythmia classification accuracy and cross-dataset robustness. The identified optimal temporal windows provide practical guidance for ECG monitoring system design and may reflect underlying physiological timescales of arrhythmogenic dynamics.

cs.LG

FeatInv: Spatially resolved mapping from feature space to input space using conditional diffusion models

Internal representations are crucial for understanding deep neural networks, such as their properties and reasoning patterns, but remain difficult to interpret. While mapping from feature space to input space aids in interpreting the former, existing approaches often rely on crude approximations. We propose using a conditional diffusion model - a pretrained high-fidelity diffusion model conditioned on spatially resolved feature maps - to learn such a mapping in a probabilistic manner. We demonstrate the feasibility of this approach across various pretrained image classifiers from CNNs to ViTs, showing excellent reconstruction capabilities. Through qualitative comparisons and robustness analysis, we validate our method and showcase possible applications, such as the visualization of concept steering in input space or investigations of the composite nature of the feature space. This approach has broad potential for improving feature space understanding in computer vision models.

cs.CV

A Multimodal Deep Learning Framework for Predicting ICU Deterioration: Integrating ECG Waveforms with Clinical Data and Clinician Benchmarking

Artificial intelligence holds strong potential to support clinical decision making in intensive care units where timely and accurate risk assessment is critical. However, many existing models focus on isolated outcomes or limited data types, while clinicians integrate longitudinal history, real time physiology, and heterogeneous clinical information. To address this gap, we developed MDS ICU, a unified multimodal machine learning framework that fuses routinely collected data including demographics, biometrics, vital signs, laboratory values, ECG waveforms, surgical procedures, and medical device usage to provide continuous predictive support during ICU stays. Using 63001 samples from 27062 patients in MIMIC IV, we trained a deep learning architecture that combines structured state space S4 encoders for ECG waveforms with multilayer perceptron RealMLP encoders for tabular data to jointly predict 33 clinically relevant outcomes spanning mortality, organ dysfunction, medication needs, and acute deterioration. The model achieved strong discrimination with AUROCs of 0.90 for 24 hour mortality, 0.92 for sedative administration, 0.97 for invasive mechanical ventilation, and 0.93 for coagulation dysfunction. Calibration analysis showed close agreement between predicted and observed risks, with consistent gains from ECG waveform integration. Comparisons with clinicians and large language models showed that model predictions alone outperformed both, and that providing model outputs as decision support further improved their performance. These results demonstrate that multimodal AI can deliver clinically meaningful risk stratification across diverse ICU outcomes while augmenting rather than replacing clinical expertise, establishing a scalable foundation for precision critical care decision support.

eess.SP

CardioLab: Laboratory Values Estimation from Electrocardiogram Features - An Exploratory Study

Laboratory value represents a cornerstone of medical diagnostics, but suffers from slow turnaround times, and high costs and only provides information about a single point in time. The continuous estimation of laboratory values from non-invasive data such as electrocardiogram (ECG) would therefore mark a significant frontier in healthcare monitoring. Despite its potential, this domain remains relatively underexplored. In this preliminary study, we used a publicly available dataset (MIMIC-IV-ECG) to investigate the feasibility of inferring laboratory values from ECG features and patient demographics using tree-based models (XGBoost). We define the prediction task as a binary problem of whether the lab value falls into low or high abnormalities. We assessed model performance with AUROC. Our findings demonstrate promising results in the estimation of laboratory values related to different organ systems. While further research and validation are warranted to fully assess the clinical utility and generalizability of the approach, our findings lay the groundwork for future investigations for laboratory value estimation using ECG data. Such advancements hold promise for revolutionizing predictive healthcare applications, offering faster, non-invasive, and more affordable means of patient monitoring.

eess.SP

Estimation of Cardiac and Non-cardiac Diagnosis from Electrocardiogram Features

Ensuring timely and accurate diagnosis of medical conditions is paramount for effective patient care. Electrocardiogram (ECG) signals are fundamental for evaluating a patient's cardiac health and are readily available. Despite this, little attention has been given to the remarkable potential of ECG data in detecting non-cardiac conditions. In our study, we used publicly available datasets (MIMIC-IV-ECG-ICD and ECG-VIEW II) to investigate the feasibility of inferring general diagnostic conditions from ECG features. To this end, we trained a tree-based model (XGBoost) based on ECG features and basic demographic features to estimate a wide range of diagnoses, encompassing both cardiac and non-cardiac conditions. Our results demonstrate the reliability of estimating 23 cardiac as well as 21 non-cardiac conditions above 0.7 AUROC in a statistically significant manner across a wide range of physiological categories. Our findings underscore the predictive potential of ECG data in identifying well-known cardiac conditions. However, even more striking, this research represents a pioneering effort in systematically expanding the scope of ECG-based diagnosis to conditions not traditionally associated with the cardiac system.

eess.SP

Explainable machine learning for neoplasms diagnosis via electrocardiograms: an externally validated study

Background: Neoplasms are a major cause of mortality globally, where early diagnosis is essential for improving outcomes. Current diagnostic methods are often invasive, expensive, and inaccessible in resource-limited settings. This study explores the potential of electrocardiogram (ECG) data, a widely available and non-invasive tool for diagnosing neoplasms through cardiovascular changes linked to neoplastic presence. Methods: A diagnostic pipeline combining tree-based machine learning models with Shapley value analysis for explainability was developed. The model was trained and internally validated on a large dataset and externally validated on an independent cohort to ensure robustness and generalizability. Key ECG features contributing to predictions were identified and analyzed. Results: The model achieved high diagnostic accuracy in both internal testing and external validation cohorts. Shapley value analysis highlighted significant ECG features, including novel predictors. The approach is cost-effective, scalable, and suitable for resource-limited settings, offering insights into cardiovascular changes associated with neoplasms and their therapies. Conclusions: This study demonstrates the feasibility of using ECG signals and machine learning for non-invasive neoplasm diagnosis. By providing interpretable insights into cardio-neoplasm interactions, this method addresses gaps in diagnostics and supports integration into broader diagnostic and therapeutic frameworks.

eess.SP

Explaining Time Series Classification Predictions via Causal Attributions

Despite the excelling performance of machine learning models, understanding their decisions remains a long-standing goal. Although commonly used attribution methods from explainable AI attempt to address this issue, they typically rely on associational rather than causal relationships. In this study, within the context of time series classification, we introduce a novel model-agnostic attribution method to assess the causal effect of concepts i.e., predefined segments within a time series, on classification outcomes. Our approach compares these causal attributions with closely related associational attributions, both theoretically and empirically. To estimate counterfactual outcomes, we use state-of-the-art diffusion models backed by state space models. We demonstrate the insights gained by our approach for a diverse set of qualitatively different time series classification tasks. Although causal and associational attributions might often share some similarities, in all cases they differ in important details, underscoring the risks associated with drawing causal conclusions from associational data alone. We believe that the proposed approach is also widely applicable in other domains to shed some light on the limits of associational attributions.

cs.LG