arXiv ScienceSearch

arXiv subjects

Nhung Nguyen

Publications and source records attributed to Nhung Nguyen.

7 recordsLinked to original sources

Solar Panel-based Visible Light Communication for Batteryless Systems

This paper presents a batteryless wireless communication node for the Internet of Things, powered entirely by ambient light and capable of receiving data through visible light communication. A solar panel serves dual functions as an energy harvester and an optical antenna, capturing modulated signals from LED light sources. A lightweight analog front-end filters and digitizes the signals for an 8-bit low-power processor, which manages the system's operational states based on stored energy levels. The main processor is selectively activated to minimize energy consumption. Data reception is synchronized with the harvester's open-circuit phase, reducing interference and improving signal quality. The prototype reliably decodes 32-bit VLC frames at 800\,Herz, consuming less than 2.8\,mJ, and maintains sleep-mode power below 30\,uW.

eess.SY

D-SarcNet: A Dual-stream Deep Learning Framework for Automatic Analysis of Sarcomere Structures in Fluorescently Labeled hiPSC-CMs

Human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) are a powerful tool in advancing cardiovascular research and clinical applications. The maturation of sarcomere organization in hiPSC-CMs is crucial, as it supports the contractile function and structural integrity of these cells. Traditional methods for assessing this maturation like manual annotation and feature extraction are labor-intensive, time-consuming, and unsuitable for high-throughput analysis. To address this, we propose D-SarcNet, a dual-stream deep learning framework that takes fluorescent hiPSC-CM single-cell images as input and outputs the stage of the sarcomere structural organization on a scale from 1.0 to 5.0. The framework also integrates Fast Fourier Transform (FFT), deep learning-generated local patterns, and gradient magnitude to capture detailed structural information at both global and local levels. Experiments on a publicly available dataset from the Allen Institute for Cell Science show that the proposed approach not only achieves a Spearman correlation of 0.868 marking a 3.7% improvement over the previous state-of-the-art but also significantly enhances other key performance metrics, including MSE, MAE, and R2 score. Beyond establishing a new state-of-the-art in sarcomere structure assessment from hiPSC-CM images, our ablation studies highlight the significance of integrating global and local information to enhance deep learning networks ability to discern and learn vital visual features of sarcomere structure.

cs.CV

SarcNet: A Novel AI-based Framework to Automatically Analyze and Score Sarcomere Organizations in Fluorescently Tagged hiPSC-CMs

Quantifying sarcomere structure organization in human-induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) is crucial for understanding cardiac disease pathology, improving drug screening, and advancing regenerative medicine. Traditional methods, such as manual annotation and Fourier transform analysis, are labor-intensive, error-prone, and lack high-throughput capabilities. In this study, we present a novel deep learning-based framework that leverages cell images and integrates cell features to automatically evaluate the sarcomere structure of hiPSC-CMs from the onset of differentiation. This framework overcomes the limitations of traditional methods through automated, high-throughput analysis, providing consistent, reliable results while accurately detecting complex sarcomere patterns across diverse samples. The proposed framework contains the SarcNet, a linear layers-added ResNet-18 module, to output a continuous score ranging from one to five that captures the level of sarcomere structure organization. It is trained and validated on an open-source dataset of hiPSC-CMs images with the endogenously GFP-tagged alpha-actinin-2 structure developed by the Allen Institute for Cell Science (AICS). SarcNet achieves a Spearman correlation of 0.831 with expert evaluations, demonstrating superior performance and an improvement of 0.075 over the current state-of-the-art approach, which uses Linear Regression. Our results also show a consistent pattern of increasing organization from day 18 to day 32 of differentiation, aligning with expert evaluations. By integrating the quantitative features calculated directly from the images with the visual features learned during the deep learning model, our framework offers a more comprehensive and accurate assessment, thereby enhancing the further utility of hiPSC-CMs in medical research and therapy development.

cs.CV

A theoretical framework for multi-physics modeling of poro-visco-hyperelasticity-induced time-dependent fracture of blood clots

Fracture resistance of blood clots plays a crucial role in physiological hemostasis and pathological thromboembolism. Although recent experimental and computational studies uncovered the poro-viscoelastic property of blood clots and its connection to the time-dependent deformation behavior, the effect of these time-dependent processes on clot fracture and the underlying time-dependent fracture mechanisms are not well understood. This work aims to formulate a thermodynamically consistent, multi-physics theoretical framework for describing the time-dependent deformation and fracture of blood clots. This theory concurrently couples fluid transport through porous fibrin networks, non-linear visco-hyperelastic deformation of the solid skeleton, solid/fluid interactions, mechanical degradation of tissues, gradient enhancement of energy, and protein unfolding of fibrin molecules. The constitutive relations of tissue constituents and the governing equation of fluid transport are derived within the framework of porous media theory by extending non-linear continuum thermodynamics at large strains. A physics-based, compressible network model is developed for the fibrin network of blood clots to describe its mechanical response. An energy-based damage model is developed to predict the damage and fracture of blood clots, and a transient non-local characterization length function is proposed to limit the damage zone bandwidth. The proposed model is experimentally validated using single-edge cracked clot specimens with different constituents. The fracture of blood clots subject to different loading conditions is simulated, and the mechanisms of clot fracture are systematically analyzed. Computational results show that the viscoelasticity and fluid transport play essential roles in the fracture of blood clots under physiological loading.

physics.med-ph

Rounded notch method of femoral endarterectomy offers mechanical advantages in finite element models

Objective: Use of a vascular punch to produce circular heel and toe arteriotomies for femoral endarterectomy with patch angioplasty is a novel technique. This study investigated the plausibility of this approach and the mechanical advantages of the technique using finite element models. Methods: The patient underwent a standard femoral endarterectomy. Prior to patch angioplasty, a 4.2 mm coronary vascular punch was used to created proximal and distal circular arteriotomies. The idealized artery was modeled as a 9 mm cylinder with a central slit. The vertices of the slit were modeled as: a sharp V consistent with traditional linear arteriotomy, circular punched hole, and beveled punched hole. The artery was pressurized to achieve displacement consistent with the size of a common femoral artery prior to patch angioplasty. Maximum von Mises stress, area-averaged stress, and stress concentration factors were evaluated for all three models. Results: Maximum von Mises stress was 0.098 MPa with 5 mm of displacement and increased to 0.26 MPa with 10 mm of displacement. Maximum stress in the uniform circular model was 0.019 MPa and 0.018 with a beveled notch. Average stress was lowest in the circular punch model at 0.006 MP and highest in the linear V notch arteriotomy at 0.010 MPa. Stress concentration factor was significantly lower in both circular models compared with the V notch. Conclusions: Femoral endarterectomy modified with the creation of circular arteriotomies is a safe and effective surgical technique. Finite element modeling revealed reduced maximum von Mises stress and average stress at the vertices of a circular or beveled punch arteriotomy compared with a linear, V shaped arteriotomy. Reduced vertex stress may promote lower risk of restenosis.

physics.med-ph

Topographic De-adhesion in the Viscoelastic Limit

The superiority of many natural surfaces at resisting soft, sticky biofoulants has inspired the integration of dynamic topography with mechanical instability to promote self-cleaning artificial surfaces. The physics behind this novel mechanism is currently limited to elastic biofoulants where surface energy, bending stiffness, and topographical wavelength are key factors. However, the viscoelastic nature of many biofoulants causes a complex interplay between these factors with time-dependent characteristics such as material softening and loading rate. Here, we enrich the current elastic theory of topographic de-adhesion using analytical and finite element models to elucidate the non-linear, time-dependent interaction of three physical, dimensionless parameters: biofoulant's stiffness reduction, product of relaxation time and loading rate, and the critical strain for short-term elastic de-adhesion. Theoretical predictions, in good agreement with numerical simulations, provide insight into tuning these control parameters to optimize surface renewal via topographic de-adhesion in the viscoelastic regime.

physics.app-ph

Resonant Gold Nanoparticles Achieve Plasmon-Enhanced Pan-Microbial Pathogen Inactivation in the Shockwave Regime

Pan-microbial inactivation technologies that do not require high temperatures, reactive chemical compounds, or UV radiation could address gaps in current infection control strategies and provide efficient sterilization of biologics in the biotechnological industry. Here, we demonstrate that femtosecond (fs) laser irradiation of resonant gold nanoparticles (NPs) under conditions that allow for E-field mediated cavitation and shockwave generation achieve an efficient plasmon-enhanced photonic microbial pathogen inactivation. We demonstrate that this NP-enhanced, physical inactivation approach is effective against a diverse group of pathogens, including both enveloped and non-enveloped viruses, and a variety of bacteria and mycoplasma. Photonic inactivation is wavelength-dependent and in the absence of plasmonic enhancement from NPs, negligible levels of microbial inactivation are observed in the near-infrared (NIR) at 800 nm. This changes upon addition of resonant plasmonic NPs, which provide a strong enhancement of inactivation of viral and bacterial contaminants. Importantly, the plasmon-enhanced 800 nm femtosecond (fs)-pulse induced inactivation was selective to pathogens. No measurable damage was observed for antibodies included as representative biologics under identical conditions.

physics.bio-ph