arXiv Science⌕ Search

arXiv subjects

Nassir Navab

Publications and source records attributed to Nassir Navab.

At least 73 records · Page 4Linked to original sources

Dyadic Partnership(DP): A Missing Link Towards Full Autonomy in Medical Robotics

For the past decades medical robotic solutions were mostly based on the concept of tele-manipulation. While their design was extremely intelligent, allowing for better access, improved dexterity, reduced tremor, and improved imaging, their intelligence was limited. They therefore left cognition and decision making to the surgeon. As medical robotics advances towards high-level autonomy, the scientific community needs to explore the required pathway towards partial and full autonomy. Here, we introduce the concept of Dyadic Partnership(DP), a new paradigm in which robots and clinicians engage in intelligent, expert interaction and collaboration. The Dyadic Partners would discuss and agree on decisions and actions during their dynamic and interactive collaboration relying also on intuitive advanced media using generative AI, such as a world model, and advanced multi-modal visualization. This article outlines the foundational components needed to enable such systems, including foundation models for clinical intelligence, multi-modal intent recognition, co-learning frameworks, advanced visualization, and explainable, trust-aware interaction. We further discuss key challenges such as data scarcity, lack of standardization, and ethical acceptance. Dyadic partnership is introduced and is positioned as a powerful yet achievable, acceptable milestone offering a promising pathway toward safer, more intuitive collaboration and a gradual transition to full autonomy across diverse clinical settings.

cs.RO↗

Physics-driven Sonification for Improving Multisensory Needle Guidance in Percutaneous Epicardial Access

Percutaneous epicardial access (PEA), performed on a beating heart under fluoroscopy, enables arrhythmia treatment. However, advancing a needle toward the thin and moving pericardium remains highly challenging and risky. To address this problem, we present a physics-driven sonification method for Extended Reality (XR)-based multisensory navigation to enhance user perception during the critical needle landing phase in PEA. Dynamic cardiac anatomy from 4D CTA was reconstructed and registered to a real-world coordinate system. Real-time needle tracking provided the position of the needle tip relative to moving cardiac structures and drove an audio-visual feedback module. The visual display presented navigational cues and dynamic anatomy, while the auditory display encoded physiological cardiac states using a multilayer physical membrane model. A phantom study was conducted with twelve cardiologists performing needle insertions under visual-only and multisensory feedback. The multisensory method significantly improved navigation safety ($χ^2 = 11.30$, $p < 0.01$), reducing myocardial contact (3.64% vs. 7.27%) and increasing correct access (90.91% vs. 52.73%). Needle placement accuracy improved, with closer membrane proximity (Cliff delta = 0.19) and reduced variability ($p < 0.05$). Execution time was comparable, while time-accuracy correlations differed significantly between modalities ($p < 0.01$). NASA-TLX indicated lower cognitive load with multisensory guidance ($p < 0.01$). These results demonstrate the feasibility of physics-driven sonification for improving spatiotemporal awareness and supporting user-centered surgical navigation.

cs.HC↗

SING3R-SLAM: Submap-based Indoor Monocular Gaussian SLAM with 3D Reconstruction Priors

Recent advances in dense 3D reconstruction have demonstrated strong capability in accurately capturing local geometry. However, extending these methods to incremental global reconstruction, as required in SLAM systems, remains challenging. Without explicit modeling of global geometric consistency, existing approaches often suffer from accumulated drift, scale inconsistency, and suboptimal local geometry. To address these issues, we propose SING3R-SLAM, a globally consistent Gaussian-based monocular indoor SLAM framework. Our approach represents the scene with a Global Gaussian Map that serves as a persistent, differentiable memory, incorporates local geometric reconstruction via submap-level global alignment, and leverages global map's consistency to further refine local geometry. This design enables efficient and versatile 3D mapping for multiple downstream applications. Extensive experiments show that SING3R-SLAM achieves state-of-the-art performance in pose estimation, 3D reconstruction, and novel view rendering. It improves pose accuracy by over 10%, produces finer and more detailed geometry, and maintains a compact and memory-efficient global representation on real-world datasets.

cs.CV↗

A 4D Representation for Training-Free Agentic Reasoning from Monocular Laparoscopic Video

Spatiotemporal reasoning is a fundamental capability for artificial intelligence (AI) in soft tissue surgery, paving the way for intelligent assistive systems and autonomous robotics. While 2D vision-language models show increasing promise at understanding surgical video, the spatial complexity of surgical scenes suggests that reasoning systems may benefit from explicit 4D representations. Here, we propose a framework for equipping surgical agents with spatiotemporal tools based on an explicit 4D representation, enabling AI systems to ground their natural language reasoning in both time and 3D space. Leveraging models for point tracking, depth, and segmentation, we develop a coherent 4D model with spatiotemporally consistent tool and tissue semantics. A Multimodal Large Language Model (MLLM) then acts as an agent on tools derived from the explicit 4D representation (e.g., trajectories) without any fine-tuning. We evaluate our method on a new dataset of 134 clinically relevant questions and find that the combination of a general purpose reasoning backbone and our 4D representation significantly improves spatiotemporal understanding and allows for 4D grounding. We demonstrate that spatiotemporal intelligence can be "assembled" from 2D MLLMs and 3D computer vision models without additional training. Code, data, and examples are available at https://tum-ai.github.io/surg4d/

cs.CV↗

Non-Rigid 3D Shape Correspondences: From Foundations to Open Challenges and Opportunities

Estimating correspondences between deformed shape instances is a long-standing problem in computer graphics; numerous applications, from texture transfer to statistical modelling, rely on recovering an accurate correspondence map. Many methods have thus been proposed to tackle this challenging problem from varying perspectives, depending on the downstream application. This state-of-the-art report is geared towards researchers, practitioners, and students seeking to understand recent trends and advances in the field. We categorise developments into three paradigms: spectral methods based on functional maps, combinatorial formulations that impose discrete constraints, and deformation-based methods that directly recover a global alignment. Each school of thought offers different advantages and disadvantages, which we discuss throughout the report. Meanwhile, we highlight the latest developments in each area and suggest new potential research directions. Finally, we provide an overview of emerging challenges and opportunities in this growing field, including the recent use of vision foundation models for zero-shot correspondence and the particularly challenging task of matching partial shapes.

cs.GR↗

UltraG-Ray: Physics-Based Gaussian Ray Casting for Novel Ultrasound View Synthesis

Novel view synthesis (NVS) in ultrasound has gained attention as a technique for generating anatomically plausible views beyond the acquired frames, offering new capabilities for training clinicians or data augmentation. However, current methods struggle with complex tissue and view-dependent acoustic effects. Physics-based NVS aims to address these limitations by including the ultrasound image formation process into the simulation. Recent approaches combine a learnable implicit scene representation with an ultrasound-specific rendering module, yet a substantial gap between simulation and reality remains. In this work, we introduce UltraG-Ray, a novel ultrasound scene representation based on a learnable 3D Gaussian field, coupled to an efficient physics-based module for B-mode synthesis. We explicitly encode ultrasound-specific parameters, such as attenuation and reflection, into a Gaussian-based spatial representation and realize image synthesis within a novel ray casting scheme. In contrast to previous methods, this approach naturally captures view-dependent attenuation effects, thereby enabling the generation of physically informed B-mode images with increased realism. We compare our method to state-of-the-art and observe consistent gains in image quality metrics (up to 15% increase on MS-SSIM), demonstrating clear improvement in terms of realism of the synthesized ultrasound images.

cs.CV↗

Towards Comprehensive Real-Time Scene Understanding in Ophthalmic Surgery through Multimodal Image Fusion

Purpose: The integration of multimodal imaging into operating rooms paves the way for comprehensive surgical scene understanding. In ophthalmic surgery, by now, two complementary imaging modalities are available: operating microscope (OPMI) imaging and real-time intraoperative optical coherence tomography (iOCT). This first work toward temporal OPMI and iOCT feature fusion demonstrates the potential of multimodal image processing for multi-head prediction through the example of precise instrument tracking in vitreoretinal surgery. Methods: We propose a multimodal, temporal, real-time capable network architecture to perform joint instrument detection, keypoint localization, and tool-tissue distance estimation. Our network design integrates a cross-attention fusion module to merge OPMI and iOCT image features, which are efficiently extracted via a YoloNAS and a CNN encoder, respectively. Furthermore, a region-based recurrent module leverages temporal coherence. Results: Our experiments demonstrate reliable instrument localization and keypoint detection (95.79% mAP50) and show that the incorporation of iOCT significantly improves tool-tissue distance estimation, while achieving real-time processing rates of 22.5 ms per frame. Especially for close distances to the retina (below 1 mm), the distance estimation accuracy improved from 284 $μm$ (OPMI only) to 33 $μm$ (multimodal). Conclusion: Feature fusion of multimodal imaging can enhance multi-task prediction accuracy compared to single-modality processing and real-time processing performance can be achieved through tailored network design. While our results demonstrate the potential of multi-modal processing for image-guided vitreoretinal surgery, they also underline key challenges that motivate future research toward more reliable, consistent, and comprehensive surgical scene understanding.

cs.CV↗

CliPPER: Contextual Video-Language Pretraining on Long-form Intraoperative Surgical Procedures for Event Recognition

Video-language foundation models have proven to be highly effective in zero-shot applications across a wide range of tasks. A particularly challenging area is the intraoperative surgical procedure domain, where labeled data is scarce, and precise temporal understanding is often required for complex downstream tasks. To address this challenge, we introduce CliPPER (Contextual Video-Language Pretraining on Long-form Intraoperative Surgical Procedures for Event Recognition), a novel video-language pretraining framework trained on surgical lecture videos. Our method is designed for fine-grained temporal video-text recognition and introduces several novel pretraining strategies to improve multimodal alignment in long-form surgical videos. Specifically, we propose Contextual Video-Text Contrastive Learning (VTC_CTX) and Clip Order Prediction (COP) pretraining objectives, both of which leverage temporal and contextual dependencies to enhance local video understanding. In addition, we incorporate a Cycle-Consistency Alignment over video-text matches within the same surgical video to enforce bidirectional consistency and improve overall representation coherence. Moreover, we introduce a more refined alignment loss, Frame-Text Matching (FTM), to improve the alignment between video frames and text. As a result, our model establishes a new state-of-the-art across multiple public surgical benchmarks, including zero-shot recognition of phases, steps, instruments, and triplets. The source code and pretraining captions can be found at https://github.com/CAMMA-public/CliPPER.

cs.CV↗

From Panel to Pixel: Zoom-In Vision-Language Pretraining from Biomedical Scientific Literature

There is a growing interest in developing strong biomedical vision-language models. A popular approach to achieve robust representations is to use web-scale scientific data. However, current biomedical vision-language pretraining typically compresses rich scientific figures and text into coarse figure-level pairs, discarding the fine-grained correspondences that clinicians actually rely on when zooming into local structures. To tackle this issue, we introduce Panel2Patch, a novel data pipeline that mines hierarchical structure from existing biomedical scientific literature, i.e., multi-panel, marker-heavy figures and their surrounding text, and converts them into multi-granular supervision. Given scientific figures and captions, Panel2Patch parses layouts, panels, and visual markers, then constructs hierarchical aligned vision-language pairs at the figure, panel, and patch levels, preserving local semantics instead of treating each figure as a single data sample. Built on this hierarchical corpus, we develop a granularity-aware pretraining strategy that unifies heterogeneous objectives from coarse didactic descriptions to fine region-focused phrases. By applying Panel2Patch to only a small set of the literature figures, we extract far more effective supervision than prior pipelines, enabling substantially better performance with less pretraining data.

cs.CV↗

Object Pose Transformer: Unifying Unseen Object Pose Estimation

Learning model-free object pose estimation for unseen instances remains a fundamental challenge in 3D vision. Existing methods typically fall into two disjoint paradigms: category-level approaches predict absolute poses in a canonical space but rely on predefined taxonomies, while relative pose methods estimate cross-view transformations but cannot recover single-view absolute pose. In this work, we propose Object Pose Transformer (\ours{}), a unified feed-forward framework that bridges these paradigms through task factorization within a single model. \ours{} jointly predicts depth, point maps, camera parameters, and normalized object coordinates (NOCS) from RGB inputs, enabling both category-level absolute SA(3) pose and unseen-object relative SE(3) pose. Our approach leverages contrastive object-centric latent embeddings for canonicalization without requiring semantic labels at inference time, and uses point maps as a camera-space representation to enable multi-view relative geometric reasoning. Through cross-frame feature interaction and shared object embeddings, our model leverages relative geometric consistency across views to improve absolute pose estimation, reducing ambiguity in single-view predictions. Furthermore, \ours{} is camera-agnostic, learning camera intrinsics on-the-fly and supporting optional depth input for metric-scale recovery, while remaining fully functional in RGB-only settings. Extensive experiments on diverse benchmarks (NOCS, HouseCat6D, Omni6DPose, Toyota-Light) demonstrate state-of-the-art performance in both absolute and relative pose estimation tasks within a single unified architecture.

cs.CV↗

FlowScene: Style-Consistent Indoor Scene Generation with Multimodal Graph Rectified Flow

Scene generation has extensive industrial applications, demanding both high realism and precise control over geometry and appearance. Language-driven retrieval methods compose plausible scenes from a large object database, but overlook object-level control and often fail to enforce scene-level style coherence. Graph-based formulations offer higher controllability over objects and inform holistic consistency by explicitly modeling relations, yet existing methods struggle to produce high-fidelity textured results, thereby limiting their practical utility. We present FlowScene, a tri-branch scene generative model conditioned on multimodal graphs that collaboratively generates scene layouts, object shapes, and object textures. At its core lies a tight-coupled rectified flow model that exchanges object information during generation, enabling collaborative reasoning across the graph. This enables fine-grained control of objects' shapes, textures, and relations while enforcing scene-level style coherence across structure and appearance. Extensive experiments show that FlowScene outperforms both language-conditioned and graph-conditioned baselines in terms of generation realism, style consistency, and alignment with human preferences.

cs.CV↗

PanORama: Multiview Consistent Panoptic Segmentation in Operating Rooms

Operating rooms (ORs) are cluttered, dynamic, highly occluded environments, where reliable spatial understanding is essential for situational awareness during complex surgical workflows. Achieving spatial understanding for panoptic segmentation from sparse multiview images poses a fundamental challenge, as limited visibility in a subset of views often leads to mispredictions across cameras. To this end, we introduce PanORama, the first panoptic segmentation for the operating room that is multiview-consistent by design. By modeling cross-view interactions at the feature level inside the backbone in a single forward pass, view consistency emerges directly rather than through post-hoc refinement. We evaluate on the MM-OR and 4D-OR datasets, achieving >70% Panoptic Quality (PQ) performance, and outperforming the previous state of the art. Importantly, PanORama is calibration-free, requiring no camera parameters, and generalizes to unseen camera viewpoints within any multiview configuration at inference time. By substantially enhancing multiview segmentation and, consequently, spatial understanding in the OR, we believe our approach opens new opportunities for surgical perception and assistance. Code will be released upon acceptance.

cs.CV↗

From Scanning Guidelines to Action: A Robotic Ultrasound Agent with LLM-Based Reasoning

Robotic ultrasound offers advantages over free-hand scanning, including improved reproducibility and reduced operator dependency. In clinical practice, US acquisition relies heavily on the sonographer's experience and situational judgment. When transferring this process to robotic systems, such expertise is often encoded explicitly through fixed procedures and task-specific models, yielding pipelines that can be difficult to adapt to new scanning tasks. In this work, we propose a unified framework for autonomous robotic US scanning that leverages a LLM-based agent to interpret US scanning guidelines and execute scans by dynamically invoking a set of provided software tools. Instead of encoding fixed scanning procedures, the LLM agent retrieves and reasons over guideline steps from scanning handbooks and adapts its planning decisions based on observations and the current scanning state. This enables the system to handle variable and decision-dependent workflows, such as adjusting scanning strategies, repeating steps, or selecting the appropriate next tool call in response to image quality or anatomical findings. Because the reasoning underlying tool selection is also critical for transparent and trustworthy planning, we further fine tune the LLM agent using a RL based strategy to improve both its reasoning quality and the correctness of tool selection and parameterization, while maintaining robust generalization to unseen guidelines and related tasks. We first validate the approach via verbal execution on 10 US scanning guidelines, assessing reasoning as well as tool selection and parameterization, and showing the benefit of RL fine tuning. We then demonstrate real world feasibility on robotic scanning of the gallbladder, spine, and kidney. Overall, the framework follows diverse guidelines and enables reliable autonomous scanning across multiple anatomical targets within a unified system.

cs.RO↗

TopoOR: A Unified Topological Scene Representation for the Operating Room

Surgical Scene Graphs abstract the complexity of surgical operating rooms (OR) into a structure of entities and their relations, but existing paradigms suffer from strictly dyadic structural limitations. Frameworks that predominantly rely on pairwise message passing or tokenized sequences flatten the manifold geometry inherent to relational structures and lose structure in the process. We introduce TopoOR, a new paradigm that models multimodal operating rooms as a higher-order structure, innately preserving pairwise and group relationships. By lifting interactions between entities into higher-order topological cells, TopoOR natively models complex dynamics and multimodality present in the OR. This topological representation subsumes traditional scene graphs, thereby offering strictly greater expressivity. We also propose a higher-order attention mechanism that explicitly preserves manifold structure and modality-specific features throughout hierarchical relational attention. In this way, we circumvent combining 3D geometry, audio, and robot kinematics into a single joint latent representation, preserving the precise multimodal structure required for safety-critical reasoning, unlike existing methods. Extensive experiments demonstrate that our approach outperforms traditional graph and LLM-based baselines across sterility breach detection, robot phase prediction, and next-action anticipation

cs.CV↗

Robotic Ultrasound Makes CBCT Alive

Intraoperative Cone Beam Computed Tomography (CBCT) provides a reliable 3D anatomical context essential for interventional planning. However, its static nature fails to provide continuous monitoring of soft-tissue deformations induced by respiration, probe pressure, and surgical manipulation, leading to navigation discrepancies. We propose a deformation-aware CBCT updating framework that leverages robotic ultrasound as a dynamic proxy to infer tissue motion and update static CBCT slices in real time. Starting from calibration-initialized alignment with linear correlation of linear combination (LC2)-based rigid refinement, our method establishes accurate multimodal correspondence. To capture intraoperative dynamics, we introduce the ultrasound correlation UNet (USCorUNet), a lightweight network trained with optical flow-guided supervision to learn deformation-aware correlation representations, enabling accurate, real-time dense deformation field estimation from ultrasound streams. The inferred deformation is spatially regularized and transferred to the CBCT reference to produce deformation-consistent visualizations without repeated radiation exposure. We validate the proposed approach through deformation estimation and ultrasound-guided CBCT updating experiments. Results demonstrate real-time end-to-end CBCT slice updating and physically plausible deformation estimation, enabling dynamic refinement of static CBCT guidance during robotic ultrasound-assisted interventions. The source code is publicly available at https://github.com/anonymous-codebase/us-cbct-demo.

cs.CV↗

DAISS: Phase-Aware Imitation Learning for Dual-Arm Robotic Ultrasound-Guided Interventions

Imitation learning has shown strong potential for automating complex robotic manipulation. In medical robotics, ultrasound-guided needle insertion demands precise bimanual coordination, as clinicians must simultaneously manipulate an ultrasound probe to maintain an optimal acoustic view while steering an interventional needle. Automating this asymmetric workflow -- and reliably transferring expert strategies to robots -- remains highly challenging. In this paper, we present the Dual-Arm Interventional Surgical System (DAISS), a teleoperated platform that collects high-fidelity dual-arm demonstrations and learns a phase-aware imitation policy for ultrasound-guided interventions. To avoid constraining the operator's natural behavior, DAISS uses a flexible NDI-based leader interface for teleoperating two coordinated follower arms. To support robust execution under real-time ultrasound feedback, we develop a lightweight, data-efficient imitation policy. Specifically, the policy incorporates a phase-aware architecture and a dynamic mask loss tailored to asymmetric bimanual control. Conditioned on a planned trajectory, the network fuses real-time ultrasound with external visual observations to generate smooth, coordinated dual-arm motions. Experimental results show that DAISS can learn personalized expert strategies from limited demonstrations. Overall, these findings highlight the promise of phase-aware imitation-learning-driven dual-arm robots for improving precision and reducing cognitive workload in image-guided interventions.

cs.RO↗

Comparative Study of Ultrasound Shape Completion and CBCT-Based AR Workflows for Spinal Needle Interventions

Purpose: This study compares two augmented reality (AR)-guided imaging workflows, one based on ultrasound shape completion and the other on cone-beam computed tomography (CBCT), for planning and executing lumbar needle interventions. The aim is to assess how imaging modality influences user performance, usability, and trust during AR-assisted spinal procedures. Methods: Both imaging systems were integrated into an AR framework, enabling in situ visualization and trajectory guidance. The ultrasound-based workflow combined AR-guided robotic scanning, probabilistic shape completion, and AR visualization. The CBCT-based workflow used AR-assisted scan volume planning, CBCT acquisition, and AR visualization. A between-subject user study was conducted and evaluated in two phases: (1) planning and image acquisition, and (2) needle insertion. Results: Planning time was significantly shorter with the CBCT-based workflow, while SUS, SEQ, and NASA-TLX were comparable between modalities. In the needle insertion phase, the CBCT-based workflow yielded marginally faster insertion times, lower placement error, and better subjective ratings with higher Trust. The ultrasound-based workflow achieved adequate accuracy for facet joint insertion, but showed larger errors for lumbar puncture, where reconstructions depended more heavily on shape completion. Conclusion: The findings indicate that both AR-guided imaging pipelines are viable for spinal intervention support. CBCT-based AR offers advantages in efficiency, precision, usability, and user confidence during insertion, whereas ultrasound-based AR provides adaptive, radiation-free imaging but is limited by shape completion in deeper spinal regions. These complementary characteristics motivate hybrid AR guidance that uses CBCT for global anatomical context and planning, augmented by ultrasound for adaptive intraoperative updates.

cs.HC↗

MMNavAgent: Multi-Magnification WSI Navigation Agent for Clinically Consistent Whole-Slide Analysis

Recent AI navigation approaches aim to improve Whole-Slide Image (WSI) diagnosis by modeling spatial exploration and selecting diagnostically relevant regions, yet most operate at a single fixed magnification or rely on predefined magnification traversal. In clinical practice, pathologists examine slides across multiple magnifications and selectively inspect only necessary scales, dynamically integrating global and cellular evidence in a sequential manner. This mismatch prevents existing methods from modeling cross-magnification interactions and adaptive magnification selection inherent to real diagnostic workflows. To these, we propose a clinically consistent Multi-Magnification WSI Navigation Agent (MMNavAgent) that explicitly models multi magnification interaction and adaptive magnification selection. Specifically, we introduce a Cross-Magnification navigation Tool (CMT) that aggregates contextual information from adjacent magnifications to enhance discriminative representations along the navigation path. We further introduce a Magnification Selection Tool (MST) that leverages memory-driven reasoning within the agent framework to enable interactive and adaptive magnification selection, mimicking the sequential decision process of pathologists. Extensive experiments on a public dataset demonstrate improved diagnostic performance, with 1.45% gain of AUC and 2.93% gain of BACC over a non-agent baseline. Code will be public upon acceptance.

cs.CV↗