arXiv ScienceSearch

arXiv subjects

N. Oliveira

Publications and source records attributed to N. Oliveira.

2 recordsLinked to original sources

Virtualized 5G Tesbed using OpenAirInterface: Tutorial and Benchmarking Tests

The development of 5G and its evolutionary path to 6G brings virtualization as close as possible to the antennas. Native 3GPP systems are now software running at servers boosted by accelerator cards to cope with computationally intense signal processing. Meanwhile, the Radio Frequency (RF) front-end is still proprietary hardware, sheltering specific PHY-layer procedures like passband amplification/modulation. This approach takes advantage of the software's flexibility while keeping the complex microsecond signal processing performance from modern telecommunication systems. This paper provides tutorial material on the Core Network and Radio Access Network of OpenAirInterface (OAI) 5G stack on top of Universal Software Radio Peripheral (USRP) platforms. A set of blueprints showcases OAI's ability to provide a virtualized 5G network with different transmission capabilities and the possibility to use it with commercial mobile phones. Configuration discussions and throughput benchmark analyses follow installation and deployment instructions. Our results show that 5G prototyping using OAI and USRP frontends can lead to good reproducibility and consistent throughput.

cs.NI

TOFHIR2: The readout ASIC of the CMS Barrel MIP Timing Detector

The CMS detector will be upgraded for the HL-LHC to include a MIP Timing Detector (MTD). The MTD will consist of barrel and endcap timing layers, BTL and ETL respectively, providing precision timing of charged particles. The BTL sensors are based on LYSO:Ce scintillation crystals coupled to SiPMs with TOFHIR2 ASICs for the front-end readout. A resolution of 30-60 ps for MIP signals at a rate of 2.5 Mhit/s per channel is expected along the HL-LHC lifetime. We present an overview of the TOFHIR2 requirements and design, simulation results and measurements with TOFHIR2 ASICs. The measurements of TOFHIR2 associated to sensor modules were performed in different test setups using internal test pulses or blue and UV laser pulses emulating the signals expected in the experiment. The measurements show a time resolution of 24 ps initially during Beginning of Operation (BoO) and 58 ps at End of Operation (EoO) conditions, matching well the BTL requirements. We also showed that the time resolution is stable up to the highest expected MIP rate. Extensive radiation tests were performed, both with x-rays and heavy ions, showing that TOFHIR2 is not affected by the radiation environment during the experiment lifetime.

physics.ins-det