arXiv ScienceSearch

arXiv subjects

Ming-Qi Cui

Publications and source records attributed to Ming-Qi Cui.

2 recordsLinked to original sources

Radiative decays of the predicted P-wave $D\bar{D}^*$ molecular state: the $0^{-+}$ case

In the present work, we study the radiative decays of the P-wave $D\bar{D}^*$ molecular state $G_0$ with $I^G(J^{PC})=0^+(0^{-+})$ using a phenomenological Lagrangian approach. The molecular coupling is fixed by the compositeness condition with a Gaussian form factor. The partial widths for $G_0\to γγ$, $γJ/ψ$, $γψ(2S)$, $γh_c$, $γρ$, and $γω$ are evaluated. Our results show that the two-photon and $γh_c$ channels are highly suppressed, while $γJ/ψ$, $γψ(2S)$, and $γρ$ are of the order of a few keV, and $γω$ reaches several tens of keV, making it the dominant radiative mode. The ratios $Γ(G_0 \to γψ(2S))/Γ(G_0 \to γJ/ψ)$ and $Γ(G_0 \to γω)/Γ(G_0 \to γρ)$ are predicted to be 1-2.6 and 3.4-5.4, respectively, with mild parameter dependence. We also compare with hadronic decays and find that the total radiative decay width is lower than the hadronic decay widths by about one order of magnitude. We propose searching for $G_0$ in the sequential decay $Y(4230)\to γG_0 \to γωJ/ψ$, which is accessible to further experimental measurements by the BESIII, Belle II and LHCb Collaborations.

hep-ph

A new soft X-ray magnetic circular dichroism facility at the BSRF beamline 4B7B

X-ray magnetic circular dichroism (XMCD) has become an important and powerful tool because it allows the study of material properties in combination with elemental specificity, chemical state specificity, and magnetic specificity. A new soft X-ray magnetic circular dichroism apparatus has been developed at the Beijing Synchrotron Radiation Facility (BSRF). The apparatus combines three experimental conditions: ultra-high-vacuum environment, moderate magnetic fields and in-situ sample preparation to measure the absorption signal. We designed a C type dipole electromagnet that provides magnetic fields up to 0.5T in parallel (or anti-parallel) direction relative to the incoming X-ray beam. The performances of the electromagnet are measured and the results show good agreement with the simulation ones. Following film grown in situ by evaporation methods, XMCD measurements are performed. Combined polarization corrections, the magnetic moments of the Fe and Co films determined by sum rules are consistent with other theoretical predictions and experimental measurements.

physics.ins-det