arXiv ScienceSearch

arXiv subjects

Michael H. Lev

Publications and source records attributed to Michael H. Lev.

2 recordsLinked to original sources

Ischemic Stroke Segmentation and Net Water Uptake Quantification on Multicenter Non-Contrast CT Using Supervised Target-Domain Adaptation

Objectives: Quantitative assessment of infarct hypodensity on non-contrast computed tomography (NCCT), including net water uptake (NWU), requires manual or semi-manual lesion delineation, often guided by CT perfusion or diffusion-weighted MRI, limiting clinical applicability. Automated segmentation on NCCT could enable efficient biomarker extraction such as NWU but remains challenging across heterogeneous multicenter data. This study aimed to develop and externally test a domain-aware deep learning framework for ischemic stroke segmentation on NCCT and assess its suitability for NWU quantification. Materials & Methods: In this retrospective multicenter study of 801 patients from four datasets, an nnU-Net-based model was trained on NCCT scans from the University Medical Center Hamburg-Eppendorf and the Acute Ischemic Stroke Dataset. To adapt to new domains, the model was fine-tuned on target-domain subsets from Boston (n=11) and ISLES (n=75), with evaluation on held-out cases not used for fine-tuning. Automated segmentations and NWU values were compared with expert references. Results: For lesions $\geq$ 30 mL, median Dice was 0.68 (Boston) and 0.56 (ISLES). Including smaller lesions, which predominated in ISLES, median Dice was 0.54 (interquartile range [IQR] 0.30-0.70) for acute lesion segmentation (Boston dataset) and 0.20 (IQR 0.03-0.41) for NCCT lesion segmentations when compared to post-treatment infarct (primary target of the ISLES challenge). Automated NWU mean absolute error was 1.37 percentage points (SD 1.61, Boston). Conclusion: Target-domain adaptation supported NCCT-only infarct segmentation across heterogeneous external cohorts, although performance varied across domains. The approach enabled low-error NWU quantification from baseline NCCT without advanced imaging, supporting further prospective clinical evaluation.

cs.CV

A Portable Brain MRI Scanner for Underserved Settings and Point-Of-Care Imaging

Access to and availability of MRI scanners is typically limited by their cost, siting and infrastructure requirements. This precludes MRI diagnostics, the reference standard for neurological assessment, in patients who cannot be transported to specialized scanner suites. This includes patients who are critically ill and unstable, and patients located in low-resource settings. The scanner design presented here aims to extend the reach of MRI by substantially reducing these limitations. Our goal is to shift the cost-benefit calculation for MRI toward more frequent and varied use, including improved accessibility worldwide and point of care operation. Here, we describe a portable brain MRI scanner using a compact, lightweight permanent magnet, with a built-in readout field gradient. Our low-field (80 mT) Halbach cylinder design of rare-earth permanent magnets results in a 122 kg magnet with minimal stray-field, requiring neither cryogenics nor external power. The built-in magnetic field gradient reduces reliance on high-power gradient drivers, which not only lowers overall system power and cooling requirements, but also reduces acoustic noise. Imperfections in the encoding fields are mitigated with a generalized iterative image reconstruction technique, that uses prior characterization of the field patterns. Our system was validated using T1, T2 and proton density weighted in vivo brain images with a spatial resolution of 2.2 x 1.3 x 6.8 mm$^3$.

eess.IV