arXiv ScienceSearch

arXiv subjects

Michael Atlan

Publications and source records attributed to Michael Atlan.

At least 19 recordsLinked to original sources

Low-rank modal endpoints from beat-resolved retinal arterial Doppler holography velocity waveforms characterize the response to flicker provocation

Conventional retinal flicker endpoints quantify changes in diameter, mean velocity, or flow but do not capture the modal concentration of the cardiac velocity waveform during neurovascular stimulation. Here, beat-resolved retinal Doppler holography and low-rank modal decomposition are combined to derive compact arterial endpoints from unfiltered arterial segment-velocity waveforms sampled across beats and vessel locations. For each acquisition, locally centered waveforms are assembled into a common matrix and decomposed by singular-value decomposition (SVD). Robust summaries quantify total pulsatile scale, modal amplitude, residual amplitude, mean-to-pulsatile balance, and singular-spectrum dimensionality; the same construction can also be applied descriptively to individual beats. We demonstrate the framework using 33 temporally ordered Baseline~1/Flicker/Baseline~2 acquisitions from one eye. Relative to the pooled baselines, 13-Hz flicker was associated with lower centered-waveform RMS scale $R_0$ and leading-mode amplitude $A_1$, and with higher robust residual-amplitude ratios $\rho_1$ and $\rho_2$, mean-to-pulsatile ratio MPR, effective rank, and participation ratio; these contrasts showed exploratory within-session separation after Holm adjustment. No evidence of differences in the absolute residual amplitudes $R_1$ and $R_2$ was detected; together, these observations are consistent with reduced concentration in the leading acquisition-specific arterial pulse mode rather than an increase in absolute residual pulsatility.

physics.med-ph

Improving segmentation of retinal arteries and veins using cardiac signal in doppler holograms

Doppler holography is an emerging retinal imaging technique that captures the dynamic behavior of blood flow with high temporal resolution, enabling quantitative assessment of retinal hemodynamics. This requires accurate segmentation of retinal arteries and veins, but traditional segmentation methods focus solely on spatial information and overlook the temporal richness of holographic data. In this work, we propose a simple yet effective approach for artery-vein segmentation in temporal Doppler holograms using standard segmentation architectures. By incorporating features derived from a dedicated pulse analysis pipeline, our method allows conventional U-Nets to exploit temporal dynamics and achieve performance comparable to more complex attention- or iteration-based models. These findings demonstrate that time-resolved preprocessing can unlock the full potential of deep learning for Doppler holography, opening new perspectives for quantitative exploration of retinal hemodynamics. The dataset is publicly available at https://huggingface.co/datasets/DigitalHolography/

cs.CV

Holovibes: real-time ultrahigh-speed digital hologram rendering and short-time analysis

Real-time ultrahigh-speed rendering of digital holograms from high-bitrate interferogram streams demands robust parallel computing and efficient data handling with minimal latency. We present Holovibes, a high-performance software engine that enables real-time holographic image reconstruction and short-time analysis at unprecedented throughput. Holovibes integrates spatial demodulation techniques, such as Fresnel transformations and angular spectrum propagation, with temporal analysis methods including short-time Fourier transform (STFT) and principal component analysis (PCA) in a unified pipeline. By leveraging CUDA-based GPU acceleration, multithreaded parallelism, and efficient buffering, the system achieves high-throughput, low-latency processing suitable for demanding computational imaging applications. We demonstrate sustained real-time hologram rendering of 256x256-pixel from interferograms acquired by a streaming camera at 71,400 frames per second on commodity hardware with no frame loss, while maintaining an end-to-end latency of 30 ms. The engine also supports simultaneous recording of raw or processed data, enabling high-speed acquisition workflows essential for experimental applications. This work represents a significant advance over prior digital holography systems and provides a versatile platform for ultra-high-speed, real-time computational imaging.

physics.optics

Retinal arterial blood flow measured by real-time Doppler holography at 33,000 frames per second

This study presents a novel quantitative estimation method for total retinal arterial blood flow utilizing real-time Doppler holography at an unprecedented frame rate of 33,000 frames per second. This technique, leveraging high-speed digital holography, enables non-invasive angiographic imaging of the retina, providing detailed blood flow contrasts essential for assessing retinal health. The proposed quantitative analysis method consists of segmenting primary in-plane retinal arteries and calculating local blood velocity using Doppler frequency broadening. The analysis integrates a forward scattering model to achieve blood flow estimation. Our findings highlight the potential of Doppler holography as a powerful tool for diagnosing and monitoring the treatment of retinal vascular conditions, complementary to existing imaging methods.

eess.IV

Doppler holography for ophthalmology

A comprehensive assessment of retinal health demands reliable and precise methods to measure localized blood perfusion. Despite considerable advancements in imaging techniques, such as indocyanine green and fluorescein angiography, along with optical coherence tomography angiography, their capacity to monitor blood flow dynamics across the cardiac cycle faces significant limitations. For more effective care of those with ocular conditions, innovating new approaches is paramount. Doppler holography, an emerging non-invasive optical imaging technique, meets this challenge by offering high temporal resolution imaging of retinal and choroidal blood flow. Now a burgeoning interdisciplinary research field, Doppler holography intertwines functional optical imaging system design, high-performance computing, and clinical investigation. Through collaborative efforts among universities, industry partners, and ophthalmic clinics, a network for its advancement and application is taking shape. This endeavor promises to propel the discovery of novel functional biomarkers, transforming the diagnosis and treatment of retinal diseases, refining disease severity categorization, and enhancing therapeutic monitoring-ultimately leading to improved healthcare outcomes.

physics.med-ph

Diffuse Maxwellian illumination for safe wide-field retinal Doppler holography

We report a diffuse Maxwellian illumination scheme for wide-field retinal laser Doppler holography. Inserting an engineered diffuser in the illumination arm transforms a spatially concentrated near-infrared laser focus into an angularly diversified illumination pattern, thereby reducing local irradiance near the anterior segment while preserving coherent interferometric detection. This configuration allows the eyepiece to be positioned closer to the cornea, increasing the digitally reconstructed retinal field of view without producing a localized corneal hot spot. We compare three illumination geometries: focused non-diffuse illumination, diffuse illumination at the same cornea--eyepiece distance, and diffuse Maxwellian illumination. Diffuse Maxwellian illumination expands the retinal field of view while preserving Doppler contrast in broad and high-frequency fluctuation bands. Light-hazard assessment is limited to the current ophthalmic standards ISO 15004-2:2024 and ANSI Z80.36-2021. Based on measured beam profiles, the recommended operating power at 852 nm is set by the most restrictive relevant exposure condition among the assessed anterior-segment, iris, and retinal limits. These results support diffuse illumination as a practical route toward safer, non-mydriatic, wide-field Doppler holography of the human retina.

physics.optics

Laser Doppler holography of the anterior segment for blood flow imaging, eye tracking, and transparency assessment

Laser Doppler holography (LDH) is a full-field blood flow imaging technique able to reveal human retinal and choroidal blood flow with high temporal resolution. We here report on using LDH in the anterior segment of the eye without making changes to the instrument. Blood flow in the bulbar conjunctiva and episclera as well as in corneal neovascularization can be effectively imaged. We additionally demonstrate simultaneous holographic imaging of the anterior and posterior segments by simply adapting the numerical propagation distance to the plane of interest. We used this feature to track the movements of the retina and pupil with high temporal resolution. Finally, we show that the light backscattered by the retina can be used for retro-illumination of the anterior segment. Hence digital holography can reveal opacities caused by absorption or diffusion in the cornea and eye lens.

physics.med-ph

Choroidal vasculature imaging with laser Doppler holography

The choroid is a highly vascularized tissues supplying the retinal pigment epithelium and photoreceptors. Its implication in retinal diseases is gaining increasing interest. However, investigating the anatomy and flow of the choroid remains challenging. Here we show that laser Doppler holography provides high contrast imaging of choroidal vessels in humans, with a spatial resolution comparable to state of the art indocyanine green angiography and optical coherence tomography. Additionally, laser Doppler holography contributes to sort out choroidal arteries and veins by using a power Doppler spectral analysis. We thus demonstrate the potential of laser Doppler holography to improve our understanding of the anatomy and flow of the choroidal vascular network.

physics.med-ph

Waveform analysis of human retinal and choroidal blood flow with laser Doppler holography

Laser Doppler holography was introduced as a full-field imaging technique to measure blood flow in the retina and choroid with an as yet unrivaled temporal resolution. We here investigate separating the different contributions to the power Doppler signal in order to isolate the flow waveforms of vessels in the posterior pole of the human eye. Distinct flow behaviors are found in retinal arteries and veins with seemingly interrelated waveforms. We demonstrate a full field mapping of the local resistivity index, and the possibility to perform unambiguous identification of retinal arteries and veins on the basis of their systolodiastolic variations. Finally we investigate the arterial flow waveforms in the retina and choroid and find synchronous and similar waveforms, although with a lower pulsatility in choroidal vessels. This work demonstrates the potential held by laser Doppler holography to study ocular hemodynamics in healthy and diseased eyes.

physics.med-ph

Retinal blood flow reversal quantitatively monitored in out-of-plane vessels with laser Doppler holography

Laser Doppler holography is a planar blood flow imaging technique recently introduced in ophthalmology to image human retinal and choroidal blood flow non-invasively. Here we present a digital method based on the Doppler spectrum asymmetry that reveals the local direction of blood flow with respect to the optical axis in out-of-plane vessels. This directional information is overlaid on standard grayscale blood flow images to depict flow moving towards the camera in red and flow moving away from the camera in blue, as in ultrasound color Doppler imaging. We show that thanks to the strong contribution of backscattering to the Doppler spectrum in out-of-plane vessels, the local axial direction of blood flow can be revealed with a high temporal resolution, which enables us to evidence pathological blood flow reversals. We also demonstrate the use of optical Doppler spectrograms to quantitatively monitor retinal blood flow reversals.

physics.med-ph

Real-time digital holography of the retina by principal component analysis

We demonstrate the feasibility of high-quality digital holography of the human retina in real-time with a fast camera and commodity computer hardware. High throughput rendering of digital Fresnel holograms from optically-acquired inline interferograms is performed in conjunction with temporal demodulation by projection of hologram sequences onto a data-derived basis in order to discriminate local narrowband coherent detection contrasts, mostly due to blood flow and optical absorption, from spurious interferometric contributions. Digital holograms are calculated from a sustained input stream of 16-bit, 1024-by-1024-pixel interferograms recorded at up to 500 frames per second, processed by principal component analysis. This temporal signal demodulation scheme consists in the projection of stacks of 32 consecutive holograms onto a basis calculated by eigendecomposition of the matrix of their time-lagged covariance; it is performed up to 20 times per second with commodity computer hardware.

physics.med-ph

Reverse contrast laser Doppler holography for lower frame rate retinal and choroidal blood flow imaging

Laser Doppler holography (LDH) is an interferometric blood flow imaging technique based on full-field measurements of the Doppler spectrum. LDH has so far been demonstrated in the retina with ultrafast cameras, typically at 75 kHz. We show here that a similar method can be implemented with camera frame rates 10 times slower than before. Thanks to energy conservation, low and high frequency local power Doppler signals have opposite variations, and a simple contrast inversion of the low frequency power Doppler reveals fast blood flow beyond the camera detection bandwidth for conventional laser Doppler measurements. Relevant blood flow variations and color composite power Doppler images can be obtained with camera frame rates down to a few kHz.

eess.IV

Spatio-temporal filtering in laser Doppler holography for retinal blood flow imaging

Laser Doppler holography (LDH) is a full-field interferometric imaging technique recently applied in ophthalmology to measure blood flow, a parameter of high clinical interest. From the temporal fluctuations of digital holograms acquired at ultrafast frame rates, LDH reveals retinal and choroidal blood flow with a few milliseconds of temporal resolution. However LDH experiences difficulties to detect slower blood flow as it requires to work with low Doppler frequency shifts which are corrupted by eye motion. We here demonstrate the use of a spatio-temporal decomposition adapted from Doppler ultrasound that provides a basis appropriate to the discrimination of blood flow from eye motion. A singular value decomposition (SVD) can be used as a simple, robust, and efficient way to separate the Doppler fluctuations of blood flow from those of strong spatial coherence such as eye motion. We show that the SVD outperforms the conventional Fourier based filter to reveal slower blood flow, and dramatically improves the ability of LDH to reveal vessels of smaller size or with a pathologically reduced blood flow.

eess.IV

Off-axis digital holography with multiplexed volume Bragg gratings

We report on an optical imaging design based on common-path off-axis digital holography, using a multiplexed volume Bragg grating. In the reported method, a reference optical wave is made by deflection and spatial filtering through a volume Bragg grating. This design has several advantages including simplicity, stability and robustness against misalignment.

physics.optics

High speed optical holography of retinal blood flow

We performed non-invasive video imaging of retinal blood flow in a pigmented rat by holographic interferometry of near-infrared laser light backscattered by retinal tissue, beating against an off-axis reference beam sampled at a frame rate of 39 kHz with a high throughput camera. Local Doppler contrasts emerged from the envelopes of short-time Fourier transforms and the phase of autocorrelation functions of holograms rendered by Fresnel transformation. This approach permitted imaging of blood flow in large retinal vessels (30 microns diameter) over 400 by 400 pixels with a spatial resolution of 8 microns and a temporal resolution of 6.5 ms.

physics.ins-det

One single static measurement predicts wave localization in complex structures

A recent theoretical breakthrough has brought a new tool, called \emph{localization landscape}, to predict the localization regions of vibration modes in complex or disordered systems. Here, we report on the first experiment which measures the localization landscape and demonstrates its predictive power. Holographic measurement of the static deformation under uniform load of a thin plate with complex geometry provides direct access to the landscape function. When put in vibration, this system shows modes precisely confined within the sub-regions delineated by the landscape function. Also the maxima of this function match the measured eigenfrequencies, while the minima of the valley network gives the frequencies at which modes become extended. This approach fully characterizes the low frequency spectrum of a complex structure from a single static measurement. It paves the way to the control and engineering of eigenmodes in any vibratory system, especially where a structural or microscopic description is not accessible.

cond-mat.dis-nn

Holographic vibrometry: Full field holographic vibrometry at ultimate limits

Heterodyne holography is an extremely versatile and powerful holographic technique that is able to fully control the amplitude, phase and frequency of both the illumination and holographic reference beams. Applied to vibration analysis, this technique is able to detect the signal of the carrier or the one of any vibration sideband. A complete analysis of the vibration signal can thus be made, and 2D map of the vibration amplitude and phase in all points of the surface of the vibrating object can be obtained. Since the sensitivity is limited by shot noise, extremely low vibration amplitude (\textless{} 0.01 nm) can be studied.

physics.optics