arXiv ScienceSearch

arXiv subjects

Mengze Gao

Publications and source records attributed to Mengze Gao.

9 recordsLinked to original sources

IT-TextFusion: Iterative Text-Image Interaction with Text-Guided Residual Refinement for Degradation-Aware Image Fusion

Text-guided image fusion has recently emerged as an effective paradigm for integrating multi-modal information while enabling flexible and task-oriented fusion control. However, existing text-guided fusion methods often rely on shallow semantic-visual interaction and limited attention mechanisms, which restrict their ability to robustly handle complex degradations and fully exploit textual guidance. In this paper, we propose an iterative text-guided image fusion framework that incorporates text-conditioned feature interaction across multiple fusion and refinement stages. The proposed method integrates deepest-level Cross-Attention, multi-scale Cross-Gate Fusion, and stage-specific text-conditioned modulation, allowing the global text embedding to condition hierarchical feature fusion and residual refinement. By repeatedly injecting the pooled text embedding across hierarchical decoder and refinement stages, the proposed framework provides degradation-aware global semantic conditioning while preserving complementary information from the visible and infrared modalities. Experiments on several benchmark datasets show that the proposed method improves several information-preservation and perceptual-quality metrics, while exhibiting metric-dependent trade-offs on some datasets.

cs.CV

Distortion-Corrected Diffusion MRI Using Rotated-View EPI and Joint Field-Map/Image Estimation with Gaussian Primitives

Echo Planar Imaging (EPI) is the standard acquisition technique for diffusion and functional neuroimaging, enabling rapid imaging but suffering from geometric distortions caused by B0 field inhomogeneities. Existing correction methods first reconstruct distorted images using parallel imaging, then estimate the B0 field and correct the distortion in the image domain. In this sequential process, reconstruction artifacts at high acceleration factors and low SNR at high diffusion b-values degrade B0 estimation and limit the overall correction quality. We propose a physics-informed framework that jointly estimates the B0 field and distortion-free image directly from k-space data, without depending on an intermediate parallel-imaging reconstruction for the correction. The image and the B0 field are each represented as a superposition of Gaussian primitives embedded within an MRI physics forward model. The explicit, continuous parameterization captures both smooth regions and tissue boundaries and supports rotated-view EPI acquisitions without interpolation. The diffusion-weighted image is modeled as real and non-negative, with the image phase absorbed into a per-shot phase factor. Rotated views distribute distortions across multiple phase-encoding orientations, improving point spread function isotropy and providing stronger constraints for B0 estimation. On in vivo brain diffusion EPI, the proposed method attains the closest brain-boundary agreement with a distortion-free structural reference, with the largest improvement over sequential methods at high b-value and high acceleration. Extensive visual comparisons further show improved detail fidelity and noise suppression.

eess.IV

A dynamic shim approach for correcting eddy current effects in diffusion-prepared MRI acquisition using a multi-coil AC/DC shim-array

Purpose: We developed a dynamic B0 shimming approach using a 46-channel AC/DC shim array to correct phase errors caused by eddy currents from diffusion-encoding gradients in diffusion-prepared MRI, enabling high b-value imaging without the SNR loss from the use of magnitude stabilizer. Methods: A 46-channel AC/DC shim array and corresponding amplifier system were built. Spin echo prescans with and without diffusion preparation were then used to rapidly measure eddy current induced phase differences. These phase maps were used as targets in an optimization framework to compute compensatory shim currents for multi-shot 3D diffusion-prepared acquisitions. Results: The proposed method allows flexible use of the AC/DC shim array to correct undesirable eddy current effects in diffusion-prepared MRI. Phantom and in vivo experiments demonstrate whole-brain, cardiac-gated, multi-shot 3D diffusion-prepared imaging without the use of magnitude stabilizers. The approach enables preservation of full SNR while achieving reliable diffusion encoding at b-values up to 2000 s/mm2. Conclusions: This work demonstrates a new strategy for applying an AC/DC shim array to compensate for eddy current induced phase errors in diffusion-prepared MRI. By eliminating the need for magnitude stabilizer, it enables efficient high-quality diffusion imaging with full signal sensitivity retained.

physics.med-ph

Enhancing Diffusion-Weighted Images (DWI) for Diffusion MRI: Is it Enough without Non-Diffusion-Weighted B=0 Reference?

Diffusion MRI (dMRI) is essential for studying brain microstructure, but high-resolution imaging remains challenging due to the inherent trade-offs between acquisition time and signal-to-noise ratio (SNR). Conventional methods often optimize only the diffusion-weighted images (DWIs) without considering their relationship with the non-diffusion-weighted (b=0) reference images. However, calculating diffusion metrics, such as the apparent diffusion coefficient (ADC) and diffusion tensor with its derived metrics like fractional anisotropy (FA) and mean diffusivity (MD), relies on the ratio between each DWI and the b=0 image, which is crucial for clinical observation and diagnostics. In this study, we demonstrate that solely enhancing DWIs using a conventional pixel-wise mean squared error (MSE) loss is insufficient, as the error in ratio between generated DWIs and b=0 diverges. We propose a novel ratio loss, defined as the MSE loss between the predicted and ground-truth log of DWI/b=0 ratios. Our results show that incorporating the ratio loss significantly improves the convergence of this ratio error, achieving lower ratio MSE and slightly enhancing the peak signal-to-noise ratio (PSNR) of generated DWIs. This leads to improved dMRI super-resolution and better preservation of b=0 ratio-based features for the derivation of diffusion metrics.

eess.IV

Physics-Informed Implicit Neural Representations for Joint B0 Estimation and Echo Planar Imaging

Echo Planar Imaging (EPI) is widely used for its rapid acquisition but suffers from severe geometric distortions due to B0 inhomogeneities, particularly along the phase encoding direction. Existing methods follow a two-step process: reconstructing blip-up/down EPI images, then estimating B0, which can introduce error accumulation and reduce correction accuracy. This is especially problematic in high B0 regions, where distortions align along the same axis, making them harder to disentangle. In this work, we propose a novel approach that integrates Implicit Neural Representations (INRs) with a physics-informed correction model to jointly estimate B0 inhomogeneities and reconstruct distortion-free images from rotated-view EPI acquisitions. INRs offer a flexible, continuous representation that inherently captures complex spatial variations without requiring predefined grid-based field maps. By leveraging this property, our method dynamically adapts to subject-specific B0 variations and improves robustness across different imaging conditions. Experimental results on 180 slices of brain images from three subjects demonstrate that our approach outperforms traditional methods in terms of reconstruction quality and field estimation accuracy.

eess.IV

ACE-Net: AutofoCus-Enhanced Convolutional Network for Field Imperfection Estimation with application to high b-value spiral Diffusion MRI

Spatiotemporal magnetic field variations from B0-inhomogeneity and diffusion-encoding-induced eddy-currents can be detrimental to rapid image-encoding schemes such as spiral, EPI and 3D-cones, resulting in undesirable image artifacts. In this work, a data driven approach for automatic estimation of these field imperfections is developed by combining autofocus metrics with deep learning, and by leveraging a compact basis representation of the expected field imperfections. The method was applied to single-shot spiral diffusion MRI at high b-values where accurate estimation of B0 and eddy were obtained, resulting in high quality image reconstruction without need for additional external calibrations.

physics.med-ph

NLCG-Net: A Model-Based Zero-Shot Learning Framework for Undersampled Quantitative MRI Reconstruction

Typical quantitative MRI (qMRI) methods estimate parameter maps in a two-step pipeline that first reconstructs images from undersampled k-space data and then performs model fitting, which is prone to biases and error propagation. We propose NLCG-Net, a model-based nonlinear conjugate gradient (NLCG) framework for joint T2/T1 estimation that incorporates a U-Net regularizer trained in a scan-specific, zero-shot fashion. The method directly estimates qMRI maps from undersampled k-space using mono-exponential signal modeling with scan-specific neural network regularization, enabling high-fidelity T1 and T2 mapping. Experimental results on T2 and T1 mapping demonstrate that NLCG-Net improves estimation quality over subspace reconstruction at high acceleration factors.

eess.IV

Sequence adaptive field-imperfection estimation (SAFE): retrospective estimation and correction of $B_1^+$ and $B_0$ inhomogeneities for enhanced MRF quantification

$B_1^+$ and $B_0$ field-inhomogeneities can significantly reduce accuracy and robustness of MRF's quantitative parameter estimates. Additional $B_1^+$ and $B_0$ calibration scans can mitigate this but add scan time and cannot be applied retrospectively to previously collected data. Here, we proposed a calibration-free sequence-adaptive deep-learning framework, to estimate and correct for $B_1^+$ and $B_0$ effects of any MRF sequence. We demonstrate its capability on arbitrary MRF sequences at 3T, where no training data were previously obtained. Such approach can be applied to any previously-acquired and future MRF-scans. The flexibility in directly applying this framework to other quantitative sequences is also highlighted.

eess.IV

Accurate parameter estimation using scan-specific unsupervised deep learning for relaxometry and MR fingerprinting

We propose an unsupervised convolutional neural network (CNN) for relaxation parameter estimation. This network incorporates signal relaxation and Bloch simulations while taking advantage of residual learning and spatial relations across neighboring voxels. Quantification accuracy and robustness to noise is shown to be significantly improved compared to standard parameter estimation methods in numerical simulations and in vivo data for multi-echo T2 and T2* mapping. The combination of the proposed network with subspace modeling and MR fingerprinting (MRF) from highly undersampled data permits high quality T1 and T2 mapping.

eess.IV