arXiv ScienceSearch

arXiv subjects

Meiling Zhou

Publications and source records attributed to Meiling Zhou.

6 recordsLinked to original sources

DXA-Derived Skeletal Phenotypes and Hip Fracture Risk: A Backdoor-Adjusted Causal Analysis

Purpose: To compare dual-energy X-ray absorptiometry (DXA)-derived hip skeletal phenotypes in relation to hip fracture risk using prespecified confounder adjustment and to assess whether phenotypes ranked by their backdoor-adjusted average treatment effects (ATEs) improve risk stratification. Methods: We analyzed 21,098 UK Biobank participants with linked health records, hip DXA-derived skeletal measures, and prespecified covariates. Sixteen phenotypes spanning bone mineral content (BMC), bone mineral density (BMD), and T-score across hip-related regions were evaluated. Confounder selection was guided by a prespecified directed acyclic graph (DAG). Backdoor-adjusted ATEs were estimated on the absolute risk-difference scale per standard deviation (SD) increase. Effect heterogeneity was evaluated for total femur BMD, and downstream prediction was assessed using clinical variables combined with phenotypes ranked by ATE magnitude. Results: Among 21,098 participants, 115 had hip fractures. All 16 phenotypes showed negative backdoor-adjusted ATEs per SD increase. The largest ATEs were observed for total femur BMC and total femur BMD, each with a risk difference of -0.0047, corresponding to approximately 4.7 fewer hip fractures per 1,000 participants per SD higher phenotype value. Conditional effects of total femur BMD were stronger among older participants and those with lower BMI. In prediction, clinical variables plus the top 11 ATE-ranked phenotypes achieved higher AUC than FRAX with femoral neck BMD (0.842 vs. 0.709), with higher sensitivity (0.748 vs. 0.443) and similar specificity (0.793 vs. 0.777). Conclusion: DXA-derived hip skeletal phenotypes differed in their backdoor-adjusted ATEs. Phenotype-level causal evaluation may help identify informative DXA measures for risk stratification.

q-bio.QM

Improving Generalizability of Hip Fracture Risk Prediction via Domain Adaptation Across Multiple Cohorts

Clinical risk prediction models often fail to be generalized across cohorts because underlying data distributions differ by clinical site, region, demographics, and measurement protocols. This limitation is particularly pronounced in hip fracture risk prediction, where the performance of models trained on one cohort (the source cohort) can degrade substantially when deployed in other cohorts (target cohorts). We used a shared set of clinical and DXA-derived features across three large cohorts - the Study of Osteoporotic Fractures (SOF), the Osteoporotic Fractures in Men Study (MrOS), and the UK Biobank (UKB), to systematically evaluate the performance of three domain adaptation methods - Maximum Mean Discrepancy (MMD), Correlation Alignment (CORAL), and Domain - Adversarial Neural Networks (DANN) and their combinations. For a source cohort with males only and a source cohort with females only, domain-adaptation methods consistently showed improved performance than the no-adaptation baseline (source-only training), and the use of combinations of multiple domain adaptation methods delivered the largest and most stable gains. The method that combines MMD, CORAL, and DANN achieved the highest discrimination with the area under curve (AUC) of 0.88 for a source cohort with males only and 0.95 for a source cohort with females only), demonstrating that integrating multiple domain adaptation methods could produce feature representations that are less sensitive to dataset differences. Unlike existing methods that rely heavily on supervised tuning or assume known outcomes of samples in target cohorts, our outcome-free approaches enable the model selection under realistic deployment conditions and improve generalization of models in hip fracture risk prediction.

cs.LG

An Advanced Two-Stage Model with High Sensitivity and Generalizability for Prediction of Hip Fracture Risk Using Multiple Datasets

Hip fractures are a major cause of disability, mortality, and healthcare burden in older adults, underscoring the need for early risk assessment. However, commonly used tools such as the DXA T-score and FRAX often lack sensitivity and miss individuals at high risk, particularly those without prior fractures or with osteopenia. To address this limitation, we propose a sequential two-stage model that integrates clinical and imaging information to improve prediction accuracy. Using data from the Osteoporotic Fractures in Men Study (MrOS), the Study of Osteoporotic Fractures (SOF), and the UK Biobank, Stage 1 (Screening) employs clinical, demographic, and functional variables to estimate baseline risk, while Stage 2 (Imaging) incorporates DXA-derived features for refinement. The model was rigorously validated through internal and external testing, showing consistent performance and adaptability across cohorts. Compared to T-score and FRAX, the two-stage framework achieved higher sensitivity and reduced missed cases, offering a cost-effective and personalized approach for early hip fracture risk assessment. Keywords: Hip Fracture, Two-Stage Model, Risk Prediction, Sensitivity, DXA, FRAX

cs.LG

Retrieval of non-sparse object through scattering media beyond the memory effect

Optical imaging through scattering media is a commonly confronted with the problem of reconstruction of complex objects and optical memory effect. To solve the problem, here, we propose a novel configuration based on the combination of ptychography and shower-curtain effect, which enables the retrieval of non-sparse samples through scattering media beyond the memory effect. Furthermore, by virtue of the shower-curtain effect, the proposed imaging system is insensitive to dynamic scattering media. Results from the retrieval of hair follicle section demonstrate the effectiveness and feasibility of the proposed method. The field of view is improved to 2.64mm. This present technique will be a potential approach for imaging through deep biological tissue.

eess.IV

Subwavelength resolution Fourier ptychography with hemispherical digital condensers

Fourier ptychography (FP) is a promising computational imaging technique that overcomes the physical space-bandwidth product (SBP) limit of a conventional microscope by applying angular diversity illuminations. However, to date, the effective imaging numerical aperture (NA) achievable with a commercial LED board is still limited to the range of 0.3 to 0.7 with a 4X0.1 NA objective due to the constraint of planar geometry with weak illumination brightness and attenuated signal-to-noise ratio (SNR). Thus the highest achievable half-pitch resolution is usually constrained between 500 to 1000 nm, which cannot fulfill some needs of high-resolution biomedical imaging applications. Although it is possible to improve the resolution by using a higher magnification objective with larger NA instead of enlarging the illumination NA, the SBP is suppressed to some extent, making the FP technique less appealing, since the reduction of field-of-view (FOV) is much larger than the improvement of resolution in this FP platform. Herein, in this paper, we initially present a subwavelength resolution Fourier ptychography (SRFP) platform with a hemispherical digital condenser to provide high-angle programmable plane-wave illuminations of 0.95NA, attaining a 4X0.1 NA objective with the final effective imaging performance of 1.05NA at a half-pitch resolution of 244 nm with a wavelength of 465 nm across a wide FOV of 14.60 mm2, corresponding to an SBP of 245 megapixels. Our work provides an essential step of FP towards high-NA imaging applications without scarfing the FOV, making it more practical and appealing.

physics.optics

SNR-based adaptive acquisition method for fast Fourier ptychographic microscopy

Fourier ptychographic microscopy (FPM) is a computational imaging technique with both high resolution and large field-of-view. However, the effective numerical aperture (NA) achievable with a typical LED panel is ambiguous and usually relies on the repeated tests of different illumination NAs. The imaging quality of each raw image usually depends on the visual assessments, which is subjective and inaccurate especially for those dark field images. Moreover, the acquisition process is really time-consuming.In this paper, we propose a SNR-based adaptive acquisition method for quantitative evaluation and adaptive collection of each raw image according to the signal-to-noise ration (SNR) value, to improve the FPM's acquisition efficiency and automatically obtain the maximum achievable NA, reducing the time of collection, storage and subsequent calculation. The widely used EPRY-FPM algorithm is applied without adding any algorithm complexity and computational burden. The performance has been demonstrated in both USAF targets and biological samples with different imaging sensors respectively, which have either Poisson or Gaussian noises model. Further combined with the sparse LEDs strategy, the number of collection images can be shorten to around 25 frames while the former needs 361 images, the reduction ratio can reach over 90%. This method will make FPM more practical and automatic, and can also be used in different configurations of FPM.

eess.IV