arXiv ScienceSearch

arXiv subjects

Md Hassanuzzaman

Publications and source records attributed to Md Hassanuzzaman.

5 recordsLinked to original sources

Clin-JEPA: A Multi-Phase Co-Training Framework for Joint-Embedding Predictive Pretraining on EHR Patient Trajectories

Joint-embedding predictive architectures (JEPA) learn representations by predicting in latent space, as in computer vision; retaining the action-conditioned predictor at inference turns them into latent world models, enabling planning in robotics (V-JEPA 2-AC). Bringing this design to EHR patient trajectories---a predictor that simulates a patient's trajectory in latent space---has not been explored. We use an LLM as the encoder, reading the hourly record as text, avoiding feature engineering and vocabulary harmonisation. But an LLM adapted by supervised fine-tuning does not organise its latent space around physiological dynamics, and freezing it to train the predictor, as in V-JEPA 2-AC, leaves the encoder unaware of the rollout signal: the predictor degrades under rollout. We instead co-train encoder and predictor under one latent-prediction objective, grounding the encoder in the dynamics its predictor must follow. Naïve co-training, however, is unstable: the untrained predictor drags the encoder toward collapse, and the predictor's rollout diverges as its target space moves. We present Clin-JEPA, a five-phase curriculum that stably co-trains an LLM encoder with a latent trajectory predictor on MIMIC-IV. Three evaluations support the design: (1) under 48-hour autoregressive rollout the co-trained predictor degrades least (predictor degradation $\times$1.06, against $\times$1.23--1.36 for two-stage designs and $\times$6.3--66 for curriculum ablations) while the co-trained encoder resolves the progression of patient state most sharply (largest state displacement); (2) the co-trained encoder separates deteriorating from stable patients in its latent space with Cohen's $d{=}1.59$, against $\leq$0.50 for two-stage encoders; (3) one set of embeddings serves 34 downstream tasks across three benchmarks, outperforming strong per-task tuned baselines and a pretrained EHR foundation model.

cs.LG

Automated detection of pediatric congenital heart disease from phonocardiograms using deep and handcrafted feature fusion

Congenital heart disease (CHD) is the most common type of birth defect, impacting about 1% of live births worldwide. Echocardiography, the gold-standard diagnostic method, is costly and inaccessible in low-resource settings. Diagnosis is delayed due to limited skilled experts, whose ability to interpret pathological patterns varies significantly, causing inter- and intra-clinician variability. Therefore, we present a new method for a more accessible diagnostic modality, the digital stethoscope, to detect CHDs. Our method is based on deep feature fusion, integrating deep and handcrafted features for the automated early detection of CHDs. For this work, Phonocardiography (PCG) recordings were obtained from 751 pediatric subjects (Age:1 month- 16 years) in Bangladesh, ranging from infants to adults at four auscultation locations: mitral valve (MV), aortic valve (AV), pulmonary valve (PV), and tricuspid valve (TV). These recordings were labeled based on confirmed diagnoses by cardiologists as either cases of CHD or non-CHD. The results demonstrated that our proposed model achieved an accuracy of 92%, a sensitivity of 91%, and a specificity of 91%, based on a patient-wise split of 70% training, 20% validation, and 10% testing. Furthermore, the Area Under the Receiver Operating Characteristic curve (AUROC) of 96%, and an F1-score of 92%. This model promises efficient real-time remote detection of CHDs as a cost-effective screening tool for low-resource settings.

cs.LG

Congenital Heart Disease Classification Using Phonocardiograms: A Scalable Screening Tool for Diverse Environments

Congenital heart disease (CHD) is a critical condition that demands early detection, particularly in infancy and childhood. This study presents a deep learning model designed to detect CHD using phonocardiogram (PCG) signals, with a focus on its application in global health. We evaluated our model on several datasets, including the primary dataset from Bangladesh, achieving a high accuracy of 94.1%, sensitivity of 92.7%, specificity of 96.3%. The model also demonstrated robust performance on the public PhysioNet Challenge 2022 and 2016 datasets, underscoring its generalizability to diverse populations and data sources. We assessed the performance of the algorithm for single and multiple auscultation sites on the chest, demonstrating that the model maintains over 85% accuracy even when using a single location. Furthermore, our algorithm was able to achieve an accuracy of 80% on low-quality recordings, which cardiologists deemed non-diagnostic. This research suggests that an AI- driven digital stethoscope could serve as a cost-effective screening tool for CHD in resource-limited settings, enhancing clinical decision support and ultimately improving patient outcomes.

eess.AS

Skin Cancer Machine Learning Model Tone Bias

Background: Many open-source skin cancer image datasets are the result of clinical trials conducted in countries with lighter skin tones. Due to this tone imbalance, machine learning models derived from these datasets can perform well at detecting skin cancer for lighter skin tones. Any tone bias in these models could introduce fairness concerns and reduce public trust in the artificial intelligence health field. Methods: We examine a subset of images from the International Skin Imaging Collaboration (ISIC) archive that provide tone information. The subset has a significant tone imbalance. These imbalances could explain a model's tone bias. To address this, we train models using the imbalanced dataset and a balanced dataset to compare against. The datasets are used to train a deep convolutional neural network model to classify the images as malignant or benign. We then evaluate the models' disparate impact, based on selection rate, relative to dark or light skin tone. Results: Using the imbalanced dataset, we found that the model is significantly better at detecting malignant images in lighter tone resulting in a disparate impact of 0.577. Using the balanced dataset, we found that the model is also significantly better at detecting malignant images in lighter versus darker tones with a disparate impact of 0.684. Using the imbalanced or balanced dataset to train the model still results in a disparate impact well below the standard threshold of 0.80 which suggests the model is biased with respect to skin tone. Conclusion: The results show that typical skin cancer machine learning models can be tone biased. These results provide evidence that diagnosis or tone imbalance is not the cause of the bias. Other techniques will be necessary to identify and address the bias in these models, an area of future investigation.

eess.IV

Classification of Short Segment Pediatric Heart Sounds Based on a Transformer-Based Convolutional Neural Network

Congenital anomalies arising as a result of a defect in the structure of the heart and great vessels are known as congenital heart diseases or CHDs. A PCG can provide essential details about the mechanical conduction system of the heart and point out specific patterns linked to different kinds of CHD. This study aims to investigate the minimum signal duration required for the automatic classification of heart sounds. This study also investigated the optimum signal quality assessment indicator (Root Mean Square of Successive Differences) RMSSD and (Zero Crossings Rate) ZCR value. Mel-frequency cepstral coefficients (MFCCs) based feature is used as an input to build a Transformer-Based residual one-dimensional convolutional neural network, which is then used for classifying the heart sound. The study showed that 0.4 is the ideal threshold for getting suitable signals for the RMSSD and ZCR indicators. Moreover, a minimum signal length of 5s is required for effective heart sound classification. It also shows that a shorter signal (3 s heart sound) does not have enough information to categorize heart sounds accurately, and the longer signal (15 s heart sound) may contain more noise. The best accuracy, 93.69%, is obtained for the 5s signal to distinguish the heart sound.

cs.SD