arXiv Science⌕ Search

arXiv subjects

Maximilian Schmid

Publications and source records attributed to Maximilian Schmid.

4 recordsLinked to original sources

Evaluation of attenuation-based simulated X-ray images for image-guided radiotherapy

In image-guided radiation therapy (IGRT), in-room X-rays are often used for patient positioning and monitoring, however, usually default imaging settings are utilized for each indication. Obtaining patient-specific imaging settings before treatment is achievable using simulated X-rays, which can facilitate IGRT workflow optimization. This study evaluated the image quality of simulated X-rays for thoracic, cranial and pelvic regions. Simulated X-rays were created from computed tomography (CT) scans with indication-specific default settings using a pre-release pilot software, which mimics the geometry of the room-mounted ExacTrac Dynamic (ETD) system (Brainlab SE, Germany). The basis of this algorithm was the Beer-Lambert law. Linear attenuation coefficients were approximated from the CT hounsfield units, while incident intensities were defined by flood images. CT scans were included from three anthropomorphic phantoms and 57 patients (13 lung, 20 glioblastoma, 24 prostate). For evaluation, real X-rays were used as ground truth. Three image quality metrics - Structural Similarity Index (SSIM), Normalized Cross Correlation (NCC), Normalized Mean Absolute Error (NMAE) - complemented by histogram and intensity profile comparisons were used for evaluation. SSIMs for phantom and patient average were 0.87 and 0.80 for the thoracic, 0.94 and 0.88 for the cranial and 0.85 and 0.79 for the pelvic region. Corresponding NCCs yielded values of 0.99 and 0.89, 0.99 and 0.99 and 0.99 and 0.60. NMAEs were 4.1% and 10.7% (lung), 2.6% and 3.2% (brain) and 2.6% and 4.0% (pelvis). Histograms of real X-rays and simulated X-rays (sX-rays) were slightly shifted and showed differences at the background pixel value. Intensity profiles exhibited similar trends with some differences in absolute values. The investigated simulated X-rays demonstrated promising quality for individualized IGRT treatment preparation.

physics.med-ph↗

Eliminating Registration Bias in Synthetic CT Generation: A Physics-Based Simulation Framework

Supervised synthetic CT generation from CBCT requires registered training pairs, yet perfect registration between separately acquired scans remains unattainable. This registration bias propagates into trained models and corrupts standard evaluation metrics. This may suggest that superior benchmark performance indicates better reproduction of registration artifacts rather than anatomical fidelity. We propose physics-based CBCT simulation to provide geometrically aligned training pairs by construction, combined with evaluation using geometric alignment metrics against input CBCT rather than biased ground truth. On two independent pelvic datasets, models trained on synthetic data achieved superior geometric alignment (Normalized Mutual Information: 0.31 vs 0.22) despite lower conventional intensity scores. Intensity metrics showed inverted correlations with clinical assessment for deformably registered data, while Normalized Mutual Information consistently predicted observer preference across registration methodologies (rho = 0.31, p < 0.001). Clinical observers preferred synthetic-trained outputs in 87% of cases, demonstrating that geometric fidelity, not intensity agreement with biased ground truth, aligns with clinical requirements.

cs.CV↗

Longitudinal spin Seebeck effect contribution in transverse spin Seebeck effect experiments in Pt/YIG and Pt/NFO

We investigate the inverse spin Hall voltage of a 10nm thin Pt strip deposited on the magnetic insulators Y3Fe5O12 (YIG) and NiFe2O4 (NFO) with a temperature gradient in the film plane. We observe characteristics typical of the spin Seebeck effect, although we do not observe a change of sign of the voltage at the Pt strip when it is moved from hot to cold side, which is believed to be the most striking feature of the transverse spin Seebeck effect. Therefore, we relate the observed voltages to the longitudinal spin Seebeck effect generated by a parasitic out-of-plane temperature gradient, which can be simulated by contact tips of different material and heat conductivities and by tip heating. This work gives new insights into the interpretation of transverse spin Seebeck effect experiments, which are still under discussion.

cond-mat.mtrl-sci↗

Influence of heat flow directions on Nernst effects in Py/Pt bilayers

We investigated the voltages obtained in a thin Pt strip on a Permalloy film which was subject to in-plane temperature gradients and magnetic fields. The voltages detected by thin W-tips or bond wires showed a purely symmetric effect with respect to the external magnetic field which can be fully explained by the planar Nernst effect (PNE). To verify the influence of the contacts measurements in vacuum and atmosphere were compared and gave similar results. We explain that a slightly in-plane tilted temperature gradient only shifts the field direction dependence but does not cancel out the observed effects. Additionally, the anomalous Nernst effect (ANE) could be induced by using thick Au-tips which generated a heat current perpendicular to the sample plane. The effect can be manipulated by varying the temperature of the Au-tips. These measurements are discussed concerning their relevance in transverse spin Seebeck effect measurements.

cond-mat.mtrl-sci↗