arXiv ScienceSearch

arXiv subjects

Maxime Rousselot

Publications and source records attributed to Maxime Rousselot.

3 recordsLinked to original sources

Classification-oriented adaptive sensing via posterior sampling

Recent advances in diffusion models have enabled high-performance, instance-adaptive compressed sensing through posterior sampling, without task-specific policy training. Existing methods select sensing probes by maximizing total posterior signal variance and are therefore primarily reconstruction-driven. We introduce a classification-driven extension motivated by the closed-form posterior covariance of a class-conditional Gaussian mixture model, which decomposes into within-class and between-class uncertainty. Using calibrated soft classifier outputs, we estimate these uncertainty terms from diffusion posterior samples and propose a classification-oriented criterion for selecting the dominant sensing direction in the unmeasured subspace. Experiments on MNIST and CIFAR-10 compare the resulting classification accuracy, measurement cost, and reconstruction quality with those of reconstruction-oriented counterparts. The results identify regimes in which semantic posterior uncertainty yields a more favorable classification--measurement trade-off and quantify the associated reconstruction cost.

eess.SP

Opportunistic Conditional Entropy Coding with Frozen Analysis and Synthesis Transforms

In many delivery settings, a receiver may already hold a lower-quality or lower-resolution representation of an image, obtained through an independent transmission. Conventional codecs encode a subsequently requested higher-quality representation without exploiting this incidental side information, whereas conditional codecs generally assume a prescribed source of side information that is always available. We instead consider an opportunistic setting in which side information may or may not be present. We introduce a single entropy model that conditions on a previously decoded latent when available and falls back to a standard hyperprior otherwise. The proposed adapter maps the side-information latent to the prior signal required by the entropy model, allowing the same model to support multiple target and side-information quality combinations. The analysis and synthesis transforms remain frozen, enabling retrofitting of an existing learned codec while preserving its latent representation and reconstruction path. When the receiver holds the quality immediately below the target, the proposed method reduces the rate of the subsequent transmission by up to 46%, or by 52% when an additional hyper-latent is transmitted. In the absence of side information, the rate penalty remains below 4%, and the reconstructions are bit-identical across the conditional and fallback modes.

eess.IV

Deep Learning-Based Beamlet Model for Generic X-Ray Beam Dose Calculation

Modeling the absorbed dose during X-ray imaging is essential for optimizing radiation exposure. Monte Carlo simulations (MCS) are the gold standard for precise 3D dose estimation but require significant computation time. Deep learning offers faster dose prediction but often lacks generality, as models are typically trained for specific anatomical sites and beam geometries. The aim in this work was proposing a generic deep-learning approach for dose calculation that can be used for multiple X-ray imaging systems. This article proposes a versatile approach combining beamlet decomposition with deep learning, where the X-ray beam is broken down into beamlets. By using a sampling approach, various beam shapes can be generated, reducing learning complexity. The model learns the dose response of a beamlet for different energies and patient properties, making it adaptable to new system geometries without altering the learning model. In this work, we propose combining two U-Net networks (1D+3D) trained on different body parts to predict the dose of a beamlet regardless of its orientation and energy. Results have shown that the deep learning-based dose engine achieved a relative dose error of approximately 1.2+/-3.87% compared to the reference dose. For a more realistic simulation in cone-beam CT, dose results exhibited a relative error within the beam of 5% compared to a full MCS. The convergence of the proposed method was faster compared to MCS, with a speedup of 130 times for equivalent dose results. The versatility of the proposed solution allows for the simulation of multiple X-ray systems without the need to retrain the deep learning model with new beam specificities. The same trained model is capable of calculating the 3D dose within the patient for helical CT, cone-beam CT, fan-beam CT, or any collimated beam shape.

physics.med-ph