arXiv ScienceSearch

arXiv subjects

Maxime Faure

Publications and source records attributed to Maxime Faure.

2 recordsLinked to original sources

Deep learning-enabled prediction of surgical errors during cataract surgery: from simulation to real-world application

Real-time prediction of technical errors from cataract surgical videos can be highly beneficial, particularly for telementoring, which involves remote guidance and mentoring through digital platforms. However, the rarity of surgical errors makes their detection and analysis challenging using artificial intelligence. To tackle this issue, we leveraged videos from the EyeSi Surgical cataract surgery simulator to learn to predict errors and transfer the acquired knowledge to real-world surgical contexts. By employing deep learning models, we demonstrated the feasibility of making real-time predictions using simulator data with a very short temporal history, enabling on-the-fly computations. We then transferred these insights to real-world settings through unsupervised domain adaptation, without relying on labeled videos from real surgeries for training, which are limited. This was achieved by aligning video clips from the simulator with real-world footage and pre-training the models using pretext tasks on both simulated and real surgical data. For a 1-second prediction window on the simulator, we achieved an overall AUC of 0.820 for error prediction using 600$\times$600 pixel images, and 0.784 using smaller 299$\times$299 pixel images. In real-world settings, we obtained an AUC of up to 0.663 with domain adaptation, marking an improvement over direct model application without adaptation, which yielded an AUC of 0.578. To our knowledge, this is the first work to address the tasks of learning surgical error prediction on a simulator using video data only and transferring this knowledge to real-world cataract surgery.

eess.IV

Volumetric and Simultaneous Photoacoustic and Ultrasound Imaging with a Conventional Linear Array in a Multiview Scanning Scheme

Volumetric, multimodal imaging with precise spatial and temporal co-registration can provide valuable and complementary information for diagnosis and monitoring. Considerable research has sought to combine 3D photoacoustic (PA) and ultrasound (US) imaging in clinically translatable configurations. However, technical compromises currently result in poor image quality either for photoacoustic or ultrasonic modes. This work aims to provide translatable, high quality, simultaneously co-registered dual-mode PA/US 3D tomography. Volumetric imaging based on a synthetic aperture approach was implemented by interlacing PA and US acquisitions during a rotate-translate scan with a 5-MHz linear array (12 angles and 30-mm translation to image a 21-mm diameter, 19 mm long cylindrical volume within 21 seconds). For co-registration, an original calibration method using a specifically designed thread phantom was developed to estimate 6 geometrical parameters and 1 temporal off-set through global optimization of the reconstructed sharpness and superposition of calibration phantom structures. Phantom design and cost function metrics were selected based on analysis of a numerical phantom, and resulted in a high estimation accuracy for the 7 parameters. Experimental estimations validated the calibration repeatability. The estimated parameters were used for bimodal reconstruction of additional phantoms with either identical or distinct spatial distributions of US and PA contrasts. Superposition distance of the two modes was within < 10% of the acoustic wavelength and a wavelength-order uniform spatial resolution was obtained. This dual-mode PA/US tomography should contribute to more sensitive and robust detection and follow-up of biological changes or the monitoring slower-kinetic phenomena in living systems such as the accumulation of nanoagents.

physics.optics