A Control Philosophy for Multiplexed Power Converters in Active Distribution Systems

Reconfigurable, multiplexed power electronic devices (M-PEDs) can provide more effective, flexible operation for applications in active distribution networks, enabling the mitigation of thermal constraints and voltage violations. To-date, operational approaches of these M-PEDs have not been described, a significant issue as a result of their relative complexity as compared to conventional PEDs. This work proposes a state machine-based control philosophy that can be used to manage the mutually exclusive selector- and current-control signals for M-PEDs. Two control approaches are described using this philosophy: an Off-Load approach, suitable for systems without time-critical network constraints; and a Hot-Swap approach, implemented when the impact of transients must be minimized. Simulations illustrate the evolution of the state machine for a back-to-back voltage source converter topology. It is concluded that the proposed state machine-based control philosophy enables M-PED operation whilst managing the additional complexity of this promising converter topology.

eess.SY

DC Link Capacitor Ripple Constraints Limit the Benefits of Utility-Owned Four-Wire Power Converters

Utilities are increasingly interested in power converters to increase the headroom of their assets by actively controlling power flows on their network. In this work we demonstrate that thermal limits of dc link capacitors can result in substantially diminished benefits of these converters under unbalanced operation, due to constraints on neutral current and double-line frequency power ripple. Considering nine voltage source converter topologies with varying ripple capabilities, the upper bound (in terms of additional headroom released) increases by more than 80% compared to a no-ripple case for the application of phase current unbalance mitigation.

eess.SY

Risk-Based Dynamic Thermal Rating in Distribution Transformers via Probabilistic Forecasting

Low voltage (LV) distribution transformers face accelerating demand growth while replacement lead times and costs continue to rise, making improved utilisation of existing assets essential. Static and conservative protection devices (PDs) in distribution transformers are inflexible and limit the available headroom of the transformer. This paper presents a probabilistic framework for dynamically forecasting optimal thermal protection settings. The proposed approach directly predicts the day-ahead scale factor which maximises the dynamic thermal rating of the transformer from historical load, temperature, and metadata using clustered quantile regression models trained on 644 UK LV transformers. Probabilistic forecasting quantifies overheating risk directly through the prediction percentile, enabling risk-informed operational decisions. Results show a 10--12\% additional capacity gain compared to static settings, with hotspot temperature risk matching the selected percentile, including under realistic temperature forecast errors. These results demonstrate a practical approach for distribution network operators to take advantage of PDs with adaptive settings to maximise capacity and manage risk on operational time scales.

eess.SY

Power Converter DC Link Ripple and Network Unbalance as Active Constraints in Distribution System Optimal Power Flow

The mitigation of unbalanced grid voltages or currents by voltage source converters results in power ripple on the dc link, and is a key converter design parameter due to hardware or stability considerations. Despite the importance of this issue for system design and operation, the use of Optimal Power Flow (OPF)-based methods capturing the interaction between dc link ripple and converter unbalanced operation has been largely unexplored. In this work, the magnitude of the power ripple is derived for generic multi-terminal converters, then introduced as a bilinear OPF constraint for two-level converter topologies. OPF case studies demonstrate the necessity to model both neutral current and dc link ripple, with tradeoffs between capacitor sizing and leg sizing highlighted for phase current unbalance mitigation applications. Time domain simulations of a grid-connected four-wire voltage source converter verify the accuracy and validity of the algebraic formulation. It is concluded that awareness of dc link ripple impacts and constraints will be of growing importance for distribution system operators.

eess.SY

Reconfigurable Power Converters with Increased Utilization for Unbalanced Power Distribution System Applications

A low-cost reconfiguration stage connected at the output of balanced three-phase, multi-terminal ac/dc/ac converters can increase the feasible set of power injections substantially, increasing converter utilization and therefore achieving a lower system cost. However, the approach has yet to be explored for phase unbalance mitigation in power distribution networks, an important application for future energy systems. This study addresses this by considering power converter reconfiguration's potential for increasing the feasible set of power transfers of four-wire power converters. Reconfigurable topologies are compared against both conventional four-wire designs and an idealised, fully reconfigurable converter. Results show that conventional converters need up to 75.3% greater capacity to yield a capability chart of equivalent size to an idealised reconfigurable converter. The number and capacity of legs impact the capability chart's size, as do constraints on dc-side power injections. The proposed approach shows significant promise for maximizing the utilization of power electronics used to mitigate impacts of phase unbalance.

eess.SY

Demonstrating Almost Linear Time Complexity of Bus Admittance Matrix-Based Distribution Network Power Flow: An Empirical Approach

The bus admittance matrix is central to many power system simulation algorithms, but the link between problem size and computation time (i.e., the time complexity) using modern sparse solvers is not fully understood. It has recently been suggested that some popular algorithms used in distribution system power flow analysis have cubic complexity, based on properties of dense matrix numerical algorithms; a tighter theoretical estimate of complexity using sparse solvers is not immediately forthcoming due to these solvers' problem-dependent behaviour. To address this, the time complexity of admittance matrix-based distribution power flow is considered empirically across a library of 75 networks, ranging in size from 50 to 300,000 nodes. Results across four admittance matrix-based methods suggest complexity coefficient values between 1.04 and 1.12, indicating complexity that is instead almost linear. The proposed empirical approach is suggested as a convenient and practical way of benchmarking the scalability of power flow algorithms.

eess.SY

Smart Energy Network Digital Twins: Findings from a UK-Based Demonstrator Project

Digital Twins promise to deliver a step-change in distribution system operations and planning, but there are few real-world examples that explore the challenges of combining imperfect model and measurement data, and then use these as the basis for subsequent analysis. In this work we propose a Digital Twin framework for electrical distribution systems and implement that framework on the Smart Energy Network Demonstrator microgrid in the UK. The data and software implementation are made available open-source, and consist of a network model, power meter measurements, and unbalanced power flow-based algorithms. Measurement and network uncertainties are shown to have a substantial impact on the quality of Digital Twin outputs. The potential benefits of a dynamic export limit and voltage control are estimated using the Digital Twin, using simulated measurements to address data quality challenges, with results showing curtailment for an exemplar day could be reduced by 56%. Power meter data and a network model are shown to be necessary for developing algorithms that enable decision-making that is robust to real-world uncertainties, with possibilities and challenges of Digital Twin development clearly demonstrated.

eess.SY

Defining and Constraining the Electrical Cardinality of Multiport Converter Mission Profiles

Mission profiles describe a representative set of conditions that a power converter is designed to operate under, and are known to be more complicated for multiport converter applications due to a wider range of combinations of powers that can be transferred between ports. This paper studies the properties of mission profiles derived from operational optimization of multiport converters in distribution system applications (e.g., soft open points). The electrical cardinality of the mission profile is introduced as a useful, naturally varying property of multiport mission profiles derived from optimal operation within distribution system, with the cardinality equal to the number of non-zero power transfers at a given time. Furthermore, it is shown that the cardinality can be conveniently constrained within the framework of conventional mixed-integer conic optimization problems, yielding a family of mission profiles that can enable converter designers to simplify multiport designs via converter reconfiguration. Results demonstrate the potential to reduce the cardinality in a four-terminal multiport converter from four to two whilst still effectively supporting congestion management and achieving 91.7% of the loss reduction capabilities of a conventional design.

eess.SY

Multiplexing Power Converters for Cost-Effective and Flexible Soft Open Points

The feasible set of real powers that can be transferred by a three-terminal Soft Open Point (SOP) can be increased by selecting non-uniform power ratings for each of the three ac/dc legs of the SOP, then connecting a multi-terminal switch (multiplexer) to the ac side of each of those converters to facilitate reconfiguration. This paper generalizes this concept, considering the real and reactive power that n multiplexed ac/dc converters can transfer at an m-feeder bus. The performance of the device is studied numerically for a number of ac/dc sizing strategies through the volume of the feasible set of power transfers (the `capability chart volume', CCV) and distribution system loss reduction benefits (as an exemplar network service). Upper bounds on device performance are defined by considering the performance of a novel, idealised SOP consisting of a continuum of infinitesimal reconfigurable converters. Results demonstrate that the CCV can be more than doubled, with 99% of the relative performance improvement of the idealised converter achieved with designs consisting of as few as four converters. SOP equipment costs reductions of 24% are reported, with it concluded that reconfigurable, judiciously sized ac/dc legs can yield flexible and lower cost SOPs than conventional, hard-wired approaches.

eess.SY

Optimal Hybrid Multiplexed AC-DC-AC converters

The flexibility of multi-terminal AC-DC-AC converters connected in distribution networks can be increased by changing the sizes of the individual AC-DC converter stages and connecting the AC side of those converters to electromechanical switches (multiplexers) to allow reconfiguration within the network. The combinations of real powers that can be transferred by such a design can be described using a capability chart. In this work, it is proposed that the area of these capability charts is a meaningful metric for describing the flexibility of such a device. These capability chart areas are calculated in closed form for a three-terminal AC-DC-AC device consisting of three AC-DC converters of arbitrary sizes, allowing the optimal AC-DC converter sizing to be determined to maximise this area. It is shown that this optimal design yields a capability chart area that is 64% larger than the equivalent area from a conventional equally-sized AC-DC-AC converter. Converters which are optimal in other senses are discussed, such as a design with 10% increased per-feeder real power transfer, albeit with an 8% area reduction. It is concluded that the capability chart area is an intuitive and informative approach for describing the increased flexibility of multiplexed AC-DC-AC converters.

eess.SY

Comparing Generator Unavailability Models with Empirical Distributions from Open Energy Datasets

The modelling of power station outages is an integral part of power system planning. In this work, models of the unavailability of the fleets of eight countries in Northwest Europe are constructed and subsequently compared against empirical distributions derived using data from the open-access ENTSO-e Transparency Platform. Summary statistics of non-sequential models highlight limitations with the empirical modelling, with very variable results across countries. Additionally, analysis of time sequential models suggests a clear need for fleet-specific analytic model parameters. Despite a number of challenges and ambiguities associated with the empirical distributions, it is suggested that a range of valuable qualitative and quantitative insights can be gained by comparing these two complementary approaches for modelling and understanding generator unavailabilities.

eess.SY

Design and Operation of Hybrid Multi-Terminal Soft Open Points using Feeder Selector Switches for Flexible Distribution System Interconnection

Distribution systems will require new cost-effective solutions to provide network capacity and increased flexibility to accommodate Low Carbon Technologies. To address this need, we propose the Hybrid Multi-Terminal Soft Open Point (Hybrid MT-SOP) to efficiently provide distribution system interconnection capacity. Each leg of the Hybrid MT-SOP has an AC/DC converter connected in series with a bank of AC switches (Feeder Selector Switches) to allow the converter to connect to any of the feeders at a node. Asymmetric converter sizing is shown to increase feasible power transfers by up to 50% in the three-terminal case, whilst a conic mixed-integer program is formulated to optimally select the device configuration and power transfers. A case study shows the Hybrid MT-SOP increasing utilization of the converters by more than one third, with a 13% increase in system loss reduction as compared to an equally-sized MT-SOP.

eess.SY

Hybrid Open Points: an Efficient Tool for Increasing Network Capacity in Distribution Systems

This letter introduces the Hybrid Open Point (HOP), a device consisting of an electromechanical switch connected in parallel with a power converter, for the purpose of providing additional network capacity in interconnected distribution systems. The HOP switch is used for bulk power transfer at low-cost, whilst the HOP converter provides targeted power transfer when the HOP switch is open. The device can replace either a Normally Open Point (Type 1 HOP) or a Normally Closed Point (Type 2 HOP). Simple interconnection and teed interconnection configurations are studied considering fault level and radiality constraints, with realistic use-cases identified for both HOP types. The HOP is shown to provide secure network capacity more cost-effectively than the classical Soft Open Point.

eess.SY

Impacts of Heat Decarbonisation on System Adequacy considering Increased Meteorological Sensitivity

This paper explores the impacts of decarbonisation of heat on demand and subsequently on the generation capacity required to secure against system adequacy standards. Gas demand is explored as a proxy variable for modelling the electrification of heating demand in existing housing stock, with a focus on impacts on timescales of capacity markets (up to four years ahead). The work considers the systemic changes that electrification of heating could introduce, including biases that could be introduced if legacy modelling approaches continue to prevail. Covariates from gas and electrical regression models are combined to form a novel, time-collapsed system model, with demand-weather sensitivities determined using lasso-regularized linear regression. It is shown, using a GB case study with one million domestic heat pump installations per year, that the sensitivity of electrical system demand to temperature (and subsequently sensitivities to cold/warm winter seasons) could increase by 50% following four years of heat demand electrification. A central estimate of 1.75 kW additional peak demand per heat pump is estimated, with variability across three published heat demand profiles leading to a range of more than 14 GW in the most extreme cases. It is shown that the legacy approach of scaling historic demand, as compared to the explicit modelling of heat, could lead to over-procurement of 0.79 GW due to bias in estimates of additional capacity to secure. Failure to address this issue could lead to {\pounds}100m overspend on capacity over ten years.

stat.AP

Hybrid European MV-LV Network Models for Smart Distribution Network Modelling

A pair of European-style, integrated MV-LV circuits are presented, created by combining generic MV and real LV networks. The two models have 86,000 and 113,000 nodes, and are made readily available for download in the OpenDSS file format. Primary substation tap change controls and MV-LV feeders are represented as three-phase unbalanced distribution network models, capturing the coupling of voltages at the MV level. The assumptions made in constructing the models are outlined, including a preconditioning step that reduces the number of nodes by more than five times without affecting the solution. Two flexibility-based case studies are presented, with TSO-DSO and peer-peer-based smart controls considered. The demonstration of the heterogeneous nature of these systems is corroborated by the analysis of measured LV voltage data. The models are intended to aid the development of algorithms for maximising the benefits of smart devices within the context of whole energy systems.

eess.SY

Calculations of System Adequacy Considering Heat Transition Pathways

The decarbonisation of heat in developed economies represents a significant challenge, with increased penetration of electrical heating technologies potentially leading to unprecedented increases in peak electricity demand. This work considers a method to evaluate the impact of rapid electrification of heat by utilising historic gas demand data. The work is intended to provide a data-driven complement to popular generative heat demand models, with a particular aim of informing regulators and actors in capacity markets as to how policy changes could impact on medium-term system adequacy metrics (up to five years ahead). Results from a GB case study show that the representation of heat demand using scaled gas demand profiles increases the rate at which 1-in-20 system peaks grow by 60\%, when compared to the use of scaled electricity demand profiles. Low end-use system efficiency, in terms of aggregate coefficient of performance and demand side response capabilities, are shown to potentially lead to a doubling of electrical demand-temperature sensitivity following five years of heat demand growth.

eess.SY

Stochastic Hosting Capacity in LV Distribution Networks

Hosting capacity is defined as the level of penetration that a particular technology can connect to a distribution network without causing power quality problems. In this work, we study the impact of solar photovoltaics (PV) on voltage rise. In most cases, the locations and sizes of the PV are not known in advance, so hosting capacity must be considered as a random variable. Most hosting capacity methods study the problem considering a large number of scenarios, many of which provide little additional information. We overcome this problem by studying only cases where voltage constraints are active, with results illustrating a reduction in the number of scenarios required by an order of magnitude. A linear power flow model is utilised for this task, showing excellent performance. The hosting capacity is finally studied as a function of the number of generators connected, demonstrating that assumptions about the penetration level will have a large impact on the conclusions drawn for a given network.

math.OC

The Value of Reactive Power for Voltage Control in Lossy Networks

Reactive power has been proposed as a method of voltage control for distribution networks, providing a means of increasing the amount of energy transferred from distributed generators to the bulk transmission network. The value of reactive power can therefore be measured according to an increase in transferred energy, where the transferred energy is defined as the total generated energy, less the total network losses. If network losses are ignored, an error in the valuation of a given amount of reactive power will be observed (leading to reactive power provision being under- or over-valued). The non-linear analytic solution of a two-bus network is studied, and non-trivial upper and lower bounds are determined for this `valuation error'. The properties predicted by this two-bus network are demonstrated to hold on a three-phase unbalanced distribution test feeder with good accuracy. This allows for an analytic assessment of the importance of losses in the valuation of reactive power in arbitrary networks.

math.OC