arXiv Science⌕ Search

arXiv subjects

Matt Valentine

Publications and source records attributed to Matt Valentine.

2 recordsLinked to original sources

Sensor-Free Shockable Rhythm Classification During CPR Using the Existing ECG Channel of Public-Access Automated External Defibrillators

Automated external defibrillators (AEDs) are public-access devices intended for use by lay rescuers, yet they must pause chest compressions to analyze the rhythm because compressions corrupt the electrocardiogram (ECG). Removing this pause requires a method that uses the hardware already present in the device, fits within its processor budget, and meets the rhythm-recognition performance required for defibrillator approval. Existing approaches rely either on an auxiliary sensor, which entails a hardware redesign, or on an additional network that reconstructs the ECG before classification. This work classifies the compression-contaminated ECG directly, using only the existing ECG channel of the AED. A cascade of three compact convolutional networks trained with different class ratios verifies each decision with a second network biased toward the proposed outcome; disagreement yields an indeterminate outcome. Evaluated on an independent manufacturer-provided cohort of 464 subjects over 15 train-validation partitions, the cascade satisfies both adjudicable American Heart Association criteria under all six noise conditions at an eight-second window and a signal-to-artifact ratio of 0 dB, with sinus-rhythm specificity of 99.20-99.43% and other non-shockable specificity of 95.48-96.20%, leaving only 1.07-1.48% of segments indeterminate. The criteria are not met at -3 dB. Single networks matched in parameter count and inference cost do not reproduce this performance. Each decision evaluates two of the three networks and requires 6.68 ms on a single thread of a general-purpose processor, and eight-bit quantization reduces the model to 1.45 MiB without changing any compliance verdict. Thus, rhythm analysis during ongoing CPR can be implemented with the ECG hardware already present in public-access AEDs, without auxiliary sensing hardware, subject to validation on the target device.

eess.SP↗

Lightweight Deep Autoencoder for ECG Denoising with Morphology Preservation and Near Real-Time Hardware Deployment

Electrocardiogram (ECG) signals are often degraded by various noise sources such as baseline wander, motion artifacts, and electromyographic interference, posing a major challenge in clinical settings. This paper presents a lightweight deep learning-based denoising framework, forming a compact autoencoder architecture. The model was trained under severe noise conditions (-5 dB signal-to-noise ratio (SNR)) using a rigorously partitioned dataset to ensure no data leakage and robust generalization. Extensive evaluations were conducted across seven noise configurations and three SNR levels (-5 dB, 0 dB, and +5 dB), showing consistent denoising performance with minimal morphological distortion, critical for maintaining diagnostic integrity. In particular, tests on clinically vital rhythms such as ventricular tachycardia (VT) and ventricular fibrillation (VF) confirm that the proposed model effectively suppresses noise without altering arrhythmic features essential for diagnosis. Visual and quantitative assessments, including SNR improvement, RMSE, and correlation metrics, validate the model's efficacy in preserving waveform fidelity. To demonstrate real-world applicability, the model was deployed on a Raspberry Pi 4 using TensorFlow Lite with float16 precision. Inference latency was measured at just 1.41 seconds per 14-second ECG segment, indicating feasibility for near-real-time use in edge devices. Overall, this study introduces a lightweight, hardware-validated, and morphologically reliable ECG denoising solution suitable for integration into portable or wearable healthcare systems.

eess.SP↗