arXiv Science⌕ Search

arXiv subjects

Marnie Goldmann

Publications and source records attributed to Marnie Goldmann.

2 recordsLinked to original sources

Patient-specific Modeling of the Tricuspid Valve from 3D Transesophageal Echocardiography

Purpose: Image-based patient-specific simulations of the tricuspid valve (TV) could support repair planning. However, clinical images incompletely resolve the chordal anatomy and cannot directly determine tissue properties, which hinders the development of such models. We developed and evaluated a framework that simulates the TV from clinical images and addresses these limitations using measurements on explanted human valves. Methods: We reconstructed ten functionally competent human TVs from 3D transesophageal echocardiography. Following manual segmentation, we automatically built finite element models with synthetic chordae and with leaflet thickness, chordal insertion density, and tissue properties informed by ex vivo human measurements. Next, we used shape matching and force-based chordal-length adjustment to simulate valve closure. We also assessed inter-observer segmentation variability and sensitivity to chordal insertion density, leaflet stiffness, leaflet thickness, and chordal size and material properties. Results: Per-valve median geometric errors were 0.61-1.13 mm relative to the morphed references and 0.55-0.95 mm relative to the image-derived surfaces. Coaptation covered 20-42% of the leaflet area, and median leaflet stresses ranged from 7.6 to 16.9 kPa. Inter-observer variability in segmentation most strongly affected coaptation area. Of the population-based inputs, insertion density and leaflet stiffness most affected geometric error. Thickness primarily affected stress, whereas chordal size and material properties had limited effects. Conclusion: Clinical echocardiography, supplemented with ex vivo human tissue data, enabled patient-specific simulation of ten human TVs. This framework provides a foundation for investigating valve mechanics and developing repair-planning tools, while sensitivity analyses identify priorities for model refinement and uncertainty assessment.

cs.CE↗

Bayesian Posterior Sampling for Synthetic Shape Generation of Heart Valves

Statistical shape models (SSMs) for heart valves commonly rely on principal component analysis (PCA). They are used to support downstream tasks, including \textit{in silico} modeling, morphological analysis, and interventional planning. However, PCA-based SSMs lack a mechanism for conditional shape generation, i.e., they can create non-physical shapes and perform poorly in low-data regimes (<20 shapes). To overcome these problems, we propose instead a Bayesian posterior sampling framework to generate valve shapes from a posterior estimate. The prior relies on a Gaussian mixture model with data-driven mixture modes. The likelihood estimate is obtained through a classifier trained to distinguish valid from invalid regions in the compact proper orthogonal decomposition (POD) coefficient space. We verify the framework on a model problem and validate it on parametrically constructed aortic valve datasets. Thereby, we demonstrate that our method captures multiple modes, respects decision boundaries in shape space, and outperforms PCA-based SSMs in low-data regimes. We also characterize the framework's performance as a function of dataset size, identifying where diminishing returns arise for the proposed generative shape model. Finally, we apply the framework to a cohort of ten three-dimensional transesophageal echocardiography images of adult human tricuspid valves. We first segment images to extract shapes, then generate a set of physiologically plausible new shapes. We demonstrate downstream applications for both valves, including \textit{in silico} modeling of valve mechanics and synthetic image-mask creation to augment limited datasets. The proposed approach bootstraps building image-mask datasets more efficiently than PCA-based SSMs. Although demonstrated only for the aortic and tricuspid valves, the methodology is broadly applicable to all valves.

cs.CE↗