arXiv Science⌕ Search

arXiv subjects

Marly van Assen

Publications and source records attributed to Marly van Assen.

6 recordsLinked to original sources

GazeRIB: Systematic Evaluation of Multi-Reader Gaze-Guided Chest X-ray Learning

Radiologists' visual attention can supervise medical image learning, but how reader panel composition affects its value remains untested. We evaluated GazeRIB (Gaze-guided Radiologist-Informed Blackout), which masks unviewed regions during training and uses unmasked images at inference. Eight experts repeatedly read the same 80 chest X-rays (CXRs). We compared individual readers with three-, five- and eight-reader panels across seven architectures and 10 seeds, evaluating 910 models on a separate 2,897-CXR cohort for four-class severity prediction. Every panel improved macro F1 over the no-gaze baseline by 5.33-7.47 percentage points (pp; Bonferroni-adjusted p < 0.007); no individual reader reached significance on this endpoint. Three readers captured 73-80% of the eight-reader gain in macro F1, the area under the receiver-operating-characteristic curve (ROC-AUC) and the area under the precision-recall curve (AU-PRC). On external validation without retraining, all four panels improved ROC-AUC on SIIM-FISABIO-RSNA by +1.93 to +4.24 pp (p <= 0.004); on MIMIC-Eye no panel differed significantly from baseline, whereas the single-reader average declined (-1.40 pp, p = 0.008). Reader composition therefore influenced performance, although transfer depended on the cohort.

cs.CV↗

CARDINAL Predicts Cardiovascular Risk From Non-contrast Cardiac CT

Cardiovascular risk prediction remains limited by incomplete clinical data and imaging biomarkers that reduce computed tomography (CT) to a small number of handcrafted features. We developed CARDINAL (Cardiovascular Assessment via Representation learning from Deep Imaging with Nested Anatomical Latent embeddings), a clinically grounded framework that learns compact representations from routine non-contrast cardiac CT for major adverse cardiovascular event (MACE) prediction. In 17,659 patients, CARDINAL was evaluated for 1-, 3-, 5-, and 10-year MACE prediction against American Heart Association (AHA) pooled cohort equations (PCE), AHA predicting risk of cardiovascular disease events (PREVENT), coronary artery calcium (CAC), segmentation-derived CT biomarkers, and 70-feature structural radiomics. Gains were largest at longer horizons. At 10 years, CARDINAL (joint) achieved an area under the receiver operating characteristic curve (AUROC) of 0.866 $\pm$ 0.020 and an area under the precision-recall curve (AUPRC) of 0.890 $\pm$ 0.015, compared with an AUROC of 0.826 $\pm$ 0.023 and an AUPRC of 0.826 $\pm$ 0.022 for structural radiomics, the strongest baseline. CARDINAL also achieved the highest survival concordance index (C-index), 0.753 $\pm$ 0.015, and high-versus-low risk-tertile hazard ratio, 10.78 $\pm$ 3.16, with favorable reclassification and exploratory calibration. These findings suggest that non-contrast cardiac CT contains prognostic information beyond conventional risk equations, CAC scoring, and engineered imaging biomarkers.

eess.IV↗

Cross-Modal Generative Framework for Signal Translation from Fetal-Maternal Electrocardiograms to Fetal Doppler Waveforms

Fetal electrocardiogram (fECG) and Doppler ultrasound provide complementary views of fetal cardiovascular function: fECG captures electrical activity while Doppler reflects mechanical hemodynamics shaped by factors such as placental resistance and vascular compliance. Understanding the recoverable and unrecoverable Doppler components through reconstruction from fECG offers insight into the relative contributions of electrical versus mechanical factors in fetal circulation, thereby informing clinical decisions. In addition, clinical evidence of maternal-fetal cardiac coupling suggests that maternal cardiovascular dynamics may also inform fetal hemodynamics. To computationally model these relationships, we propose a cross-modal generative framework combining dilated convolutions with cross-modal attention to selectively incorporate maternal ECG and self-attention to capture long-range temporal dependencies. Trained on 885 synchronized fetal/maternal ECG and Doppler envelope segments from 39 pregnancies, our model synthesizes Doppler envelopes with power spectral density mean squared error (PSD MSE) of 49.9 +/- 15.8 dB^2 (51% lower than two-channel baseline) and heart-rate error of 4.71 +/- 0.77 bpm (1.5% better than baseline; negligible relative to the 110-160 bpm physiological range). Cross-modal attention yields a 39% PSD MSE reduction over naive dual-channel concatenation, quantifying the contribution of maternal-fetal coupling. Our proposed framework advances computational modeling of the maternal-fetal cardiovascular system by enabling the synthesis of Doppler envelopes from dual-lead ECG. By analysis of both recoverable and residual Doppler components, this approach enables quantification of the purely mechanical contributions to Doppler waveforms -- those not recoverable from electrical recordings -- ultimately facilitating a more comprehensive fetal assessment.

cs.LG↗

Comp2Comp: Open-Source Software with FDA-Cleared Artificial Intelligence Algorithms for Computed Tomography Image Analysis

Artificial intelligence allows automatic extraction of imaging biomarkers from already-acquired radiologic images. This paradigm of opportunistic imaging adds value to medical imaging without additional imaging costs or patient radiation exposure. However, many open-source image analysis solutions lack rigorous validation while commercial solutions lack transparency, leading to unexpected failures when deployed. Here, we report development and validation for two of the first fully open-sourced, FDA-510(k)-cleared deep learning pipelines to mitigate both challenges: Abdominal Aortic Quantification (AAQ) and Bone Mineral Density (BMD) estimation are both offered within the Comp2Comp package for opportunistic analysis of computed tomography scans. AAQ segments the abdominal aorta to assess aneurysm size; BMD segments vertebral bodies to estimate trabecular bone density and osteoporosis risk. AAQ-derived maximal aortic diameters were compared against radiologist ground-truth measurements on 258 patient scans enriched for abdominal aortic aneurysms from four external institutions. BMD binary classifications (low vs. normal bone density) were compared against concurrent DXA scan ground truths obtained on 371 patient scans from four external institutions. AAQ had an overall mean absolute error of 1.57 mm (95% CI 1.38-1.80 mm). BMD had a sensitivity of 81.0% (95% CI 74.0-86.8%) and specificity of 78.4% (95% CI 72.3-83.7%). Comp2Comp AAQ and BMD demonstrated sufficient accuracy for clinical use. Open-sourcing these algorithms improves transparency of typically opaque FDA clearance processes, allows hospitals to test the algorithms before cumbersome clinical pilots, and provides researchers with best-in-class methods.

cs.CV↗

Deep Active Learning for Lung Disease Severity Classification from Chest X-rays: Learning with Less Data in the Presence of Class Imbalance

To reduce the amount of required labeled data for lung disease severity classification from chest X-rays (CXRs) under class imbalance, this study applied deep active learning with a Bayesian Neural Network (BNN) approximation and weighted loss function. This retrospective study collected 2,319 CXRs from 963 patients (mean age, 59.2 $\pm$ 16.6 years; 481 female) at Emory Healthcare affiliated hospitals between January and November 2020. All patients had clinically confirmed COVID-19. Each CXR was independently labeled by 3 to 6 board-certified radiologists as normal, moderate, or severe. A deep neural network with Monte Carlo Dropout was trained using active learning to classify disease severity. Various acquisition functions were used to iteratively select the most informative samples from an unlabeled pool. Performance was evaluated using accuracy, area under the receiver operating characteristic curve (AU ROC), and area under the precision-recall curve (AU PRC). Training time and acquisition time were recorded. Statistical analysis included descriptive metrics and performance comparisons across acquisition strategies. Entropy Sampling achieved 93.7% accuracy (AU ROC, 0.91) in binary classification (normal vs. diseased) using 15.4% of the training data. In the multi-class setting, Mean STD sampling achieved 70.3% accuracy (AU ROC, 0.86) using 23.1% of the labeled data. These methods outperformed more complex and computationally expensive acquisition functions and significantly reduced labeling needs. Deep active learning with BNN approximation and weighted loss effectively reduces labeled data requirements while addressing class imbalance, maintaining or exceeding diagnostic performance.

eess.IV↗

Novel AI-Based Quantification of Breast Arterial Calcification to Predict Cardiovascular Risk

Women are underdiagnosed and undertreated for cardiovascular disease. Automatic quantification of breast arterial calcification on screening mammography can identify women at risk for cardiovascular disease and enable earlier treatment and management of disease. In this retrospective study of 116,135 women from two healthcare systems, a transformer-based neural network quantified BAC severity (no BAC, mild, moderate, and severe) on screening mammograms. Outcomes included major adverse cardiovascular events (MACE) and all-cause mortality. BAC severity was independently associated with MACE after adjusting for cardiovascular risk factors, with increasing hazard ratios from mild (HR 1.18-1.22), moderate (HR 1.38-1.47), to severe BAC (HR 2.03-2.22) across datasets (all p<0.001). This association remained significant across all age groups, with even mild BAC indicating increased risk in women under 50. BAC remained an independent predictor when analyzed alongside ASCVD risk scores, showing significant associations with myocardial infarction, stroke, heart failure, and mortality (all p<0.005). Automated BAC quantification enables opportunistic cardiovascular risk assessment during routine mammography without additional radiation or cost. This approach provides value beyond traditional risk factors, particularly in younger women, offering potential for early CVD risk stratification in the millions of women undergoing annual mammography.

eess.IV↗