arXiv ScienceSearch

arXiv subjects

Mark Chiew

Publications and source records attributed to Mark Chiew.

11 recordsLinked to original sources

Optimized Multi-Contrast Self-Supervised MRI Reconstruction using Learned k-space Partitioning

Objective: Deep Learning has shown promise in accelerating MRI by reconstructing high-quality images from under-sampled data. While recent work has leveraged multi-contrast information to improve reconstruction performance, these methods rely on supervised learning, which requires fully sampled k-space for training. One method, self-supervised learning via data undersampling (SSDU), enables direct training on under-sampled k-space by partitioning it into two sets, with a network mapping between the two. In this work, we improve MRI self-supervised MRI reconstruction with two modifications. Methods: We propose a multi-contrast self-supervised learning framework that jointly trains on multiple under-sampled contrasts without requiring fully sampled k-space data as a reference. Moreover, we learn an optimal self-supervised data partitioning for each contrast in an end-to-end manner, further enhancing reconstruction quality. Specifically, we learn an optimal partitioning probability distribution, which is sampled to generate a mask for partitioning. Results: Experiments on two publicly available multi-contrast MRI datasets demonstrate the improved reconstruction quality of our proposed self-supervised multi-contrast learned partitioning method compared to the current single-contrast self-supervised learning methods. We also demonstrate that learning the partitioning of k-space data further enhances the fidelity of reconstructions. Conclusion: Multi-contrast reconstruction combined with learned partitioning improves reconstruction fidelity over single-contrast self-supervised MRI reconstructions. Significance: Our method can facilitate higher image fidelity and/or accelerated MRI protocol times compared to previous self-supervised methods, and without requiring fully sampled k-space for training.

eess.IV

Fast and Robust T1 Mapping Based on a 3D Dual-Echo UTE Sequence (PETALUTE) for SPION Biodistribution Assessment

Superparamagnetic iron oxide nanoparticles (SPIONs) such as ferumoxytol are promising theranostic agents detectable with MRI. Relaxation time mapping offers reproducible, quantitative biomarkers of SPION distribution, but conventional methods suffer from susceptibility artifacts, long echo times, and extended scan durations, limiting accurate quantification. This study developed a fast, B1-corrected T1-mapping protocol using PETALUTE, a 3D dual-echo ultrashort-echo MRI sequence with a rosette k-space trajectory and variable flip-angle acquisition for quantitative ferumoxytol imaging. Agarose phantoms containing 0-5000 ppm ferumoxytol were scanned at 7T with PETALUTE and vendor-supplied RARE-VTR. PETALUTE T1 maps were derived from two flip angles (4 deg and 20 deg), and mean R1 values were correlated with ferumoxytol concentration. For in vivo feasibility, mice bearing 4T1 mammary and flank tumors were scanned 24 h post-injection (ferumoxytol: n=2, 40 mg/kg; control: n=1). Regions of interest in muscle and tumors were analyzed to compare T1 and R1 values obtained with both methods. PETALUTE produced positive contrast for all phantom concentrations except 5000 ppm, whereas RARE-VTR did not. PETALUTE demonstrated a significant linear correlation between R1 and ferumoxytol concentration (R=0.975, p<0.01), in contrast to RARE-VTR (R=0.672, p=0.144). In vivo, PETALUTE enabled high-resolution, whole-abdominal imaging in 4 min 19 s. Ferumoxytol-injected mice showed T1 shortening in flank tumors, consistent with iron uptake, and PETALUTE revealed elevated T1 value with preserved T2*-weighted signal in one mammary tumor. PETALUTE-based T1 mapping provides fast, quantitative, positive-contrast ferumoxytol imaging with greater spatial coverage and a wider usable concentration range than conventional RARE-VTR.

physics.med-ph

Accelerated Cardiac Parametric Mapping using Deep Learning-Refined Subspace Models

Cardiac parametric mapping is useful for evaluating cardiac fibrosis and edema. Parametric mapping relies on single-shot heartbeat-by-heartbeat imaging, which is susceptible to intra-shot motion during the imaging window. However, reducing the imaging window requires undersampled reconstruction techniques to preserve image fidelity and spatial resolution. The proposed approach is based on a low-rank tensor model of the multi-dimensional data, which jointly estimates spatial basis images and temporal basis time-courses from an auxiliary parallel imaging reconstruction. The tensor-estimated spatial basis is then further refined using a deep neural network, trained in a fully supervised fashion, improving the fidelity of the spatial basis using learned representations of cardiac basis functions. This two-stage spatial basis estimation will be compared against Fourier-based reconstructions and parallel imaging alone to demonstrate the sharpening and denoising properties of the deep learning-based subspace analysis.

eess.IV

Low-Rank Conjugate Gradient-Net for Accelerated Cardiac MR Imaging

Cardiovascular diseases (CVDs) remain the leading cause of mortality and morbidity worldwide. Both diagnosis and prognosis of these diseases benefit from high-quality imaging, which cardiac magnetic resonance imaging provides. CMR imaging requires lengthy acquisition times and multiple breath-holds for a complete exam, which can lead to patient discomfort and frequently results in image artifacts. In this work, we present a Low-rank tensor U-Net method (LowRank-CGNet) that rapidly reconstructs highly undersampled data with a variety of anatomy, contrast, and undersampling artifacts. The model uses conjugate gradient data consistency to solve for the spatial and temporal bases and employs a U-Net to further regularize the basis vectors. Currently, model performance is superior to a standard U-Net, but inferior to conventional compressed sensing methods. In the future, we aim to further improve model performance by increasing the U-Net size, extending the training duration, and dynamically updating the tensor rank for different anatomies.

eess.IV

Self-navigated 3D diffusion MRI using an optimized CAIPI sampling and structured low-rank reconstruction

3D multi-slab acquisitions are an appealing approach for diffusion MRI because they are compatible with the imaging regime delivering optimal SNR efficiency. In conventional 3D multi-slab imaging, shot-to-shot phase variations caused by motion pose challenges due to the use of multi-shot k-space acquisition. Navigator acquisition after each imaging echo is typically employed to correct phase variations, which prolongs scan time and increases the specific absorption rate (SAR). The aim of this study is to develop a highly efficient, self-navigated method to correct for phase variations in 3D multi-slab diffusion MRI without explicitly acquiring navigators. The sampling of each shot is carefully designed to intersect with the central kz plane of each slab, and the multi-shot sampling is optimized for self-navigation performance while retaining decent reconstruction quality. The central kz intersections from all shots are jointly used to reconstruct a 2D phase map for each shot using a structured low-rank constrained reconstruction that leverages the redundancy in shot and coil dimensions. The phase maps are used to eliminate the shot-to-shot phase inconsistency in the final 3D multi-shot reconstruction. We demonstrate the method's efficacy using retrospective simulations and prospectively acquired in-vivo experiments at 1.22 mm and 1.09 mm isotropic resolutions. Compared to conventional navigated 3D multi-slab imaging, the proposed self-navigated method achieves comparable image quality while shortening the scan time by 31.7% and improving the SNR efficiency by 15.5%. The proposed method produces comparable quality of DTI and white matter tractography to conventional navigated 3D multi-slab acquisition with a much shorter scan time.

physics.med-ph

Clean self-supervised MRI reconstruction from noisy, sub-sampled training data with Robust SSDU

Most existing methods for Magnetic Resonance Imaging (MRI) reconstruction with deep learning use fully supervised training, which assumes that a high signal-to-noise ratio (SNR), fully sampled dataset is available for training. In many circumstances, however, such a dataset is highly impractical or even technically infeasible to acquire. Recently, a number of self-supervised methods for MR reconstruction have been proposed, which use sub-sampled data only. However, the majority of such methods, such as Self-Supervised Learning via Data Undersampling (SSDU), are susceptible to reconstruction errors arising from noise in the measured data. In response, we propose Robust SSDU, which provably recovers clean images from noisy, sub-sampled training data by simultaneously estimating missing k-space samples and denoising the available samples. Robust SSDU trains the reconstruction network to map from a further noisy and sub-sampled version of the data to the original, singly noisy and sub-sampled data, and applies an additive Noisier2Noise correction term at inference. We also present a related method, Noiser2Full, that recovers clean images when noisy, fully sampled data is available for training. Both proposed methods are applicable to any network architecture, straight-forward to implement and have similar computational cost to standard training. We evaluate our methods on the multi-coil fastMRI brain dataset with a novel denoising-specific architecture and find that it performs competitively with a benchmark trained on clean, fully sampled data.

eess.IV

A theoretical framework for self-supervised MR image reconstruction using sub-sampling via variable density Noisier2Noise

In recent years, there has been attention on leveraging the statistical modeling capabilities of neural networks for reconstructing sub-sampled Magnetic Resonance Imaging (MRI) data. Most proposed methods assume the existence of a representative fully-sampled dataset and use fully-supervised training. However, for many applications, fully sampled training data is not available, and may be highly impractical to acquire. The development and understanding of self-supervised methods, which use only sub-sampled data for training, are therefore highly desirable. This work extends the Noisier2Noise framework, which was originally constructed for self-supervised denoising tasks, to variable density sub-sampled MRI data. We use the Noisier2Noise framework to analytically explain the performance of Self-Supervised Learning via Data Undersampling (SSDU), a recently proposed method that performs well in practice but until now lacked theoretical justification. Further, we propose two modifications of SSDU that arise as a consequence of the theoretical developments. Firstly, we propose partitioning the sampling set so that the subsets have the same type of distribution as the original sampling mask. Secondly, we propose a loss weighting that compensates for the sampling and partitioning densities. On the fastMRI dataset we show that these changes significantly improve SSDU's image restoration quality and robustness to the partitioning parameters.

eess.IV

Time-encoded pseudo-continuous arterial spin labeling: increasing SNR in ASL angiography

Purpose: Dynamic angiography using arterial spin labeling (ASL) can provide detailed hemodynamic information. However, the long time-resolved readouts require small flip angles to preserve ASL signal for later timepoints, limiting SNR. By using time-encoded ASL to generate temporal information, the readout can be shortened. Here, the improvements in SNR from using larger flip angles, made possible by the shorter readout, are quantitatively investigated. Methods: The SNR of a conventional (sequential) protocol with 9 readouts and a 4-by-3 time-encoded protocol with 3 readouts (giving 9 matched timepoints) were directly compared using simulations and in vivo data. Both protocols were compared using readouts with constant (CFA) and variable flip angles (VFA), where the VFA scheme was designed to produce a consistent ASL signal across readouts. Optimization of the background suppression to minimize physiological noise across readouts was also explored. Results: The time-encoded protocol increased in vivo SNR by 103% and 96% when using CFAs or VFAs, respectively. Use of VFAs improved SNR compared to CFAs by 25% and 21% for the sequential and time-encoded protocols, respectively. The VFA scheme also removed signal discontinuities in the time-encoded data. Preliminary data suggest optimizing the background suppression could improve in vivo SNR by a further 16%. Conclusion: Time-encoding can be used to generate additional temporal information in ASL angiography. This enables the use of larger flip angles which can double the SNR compared to a non-time-encoded protocol. The shortened time-encoded readout can also lead to improved background suppression, reducing physiological noise and further improving SNR.

physics.med-ph

Tuning-free multi-coil compressed sensing MRI with Parallel Variable Density Approximate Message Passing (P-VDAMP)

Magnetic Resonance Imaging (MRI) has excellent soft tissue contrast but is hindered by an inherently slow data acquisition process. Compressed sensing, which reconstructs sparse signals from incoherently sampled data, has been widely applied to accelerate MRI acquisitions. Compressed sensing MRI requires one or more model parameters to be tuned, which is usually done by hand, giving sub-optimal tuning in general. To address this issue, we build on previous work by the authors on the single-coil Variable Density Approximate Message Passing (VDAMP) algorithm, extending the framework to multiple receiver coils to propose the Parallel VDAMP (P-VDAMP) algorithm. For Bernoulli random variable density sampling, P-VDAMP obeys a "state evolution", where the intermediate per-iteration image estimate is distributed according to the ground truth corrupted by a zero-mean Gaussian vector with approximately known covariance. To our knowledge, P-VDAMP is the first algorithm for multi-coil MRI data that obeys a state evolution with accurately tracked parameters. We leverage state evolution to automatically tune sparse parameters on-the-fly with Stein's Unbiased Risk Estimate (SURE). P-VDAMP is evaluated on brain, knee and angiogram datasets and compared with four variants of the Fast Iterative Shrinkage-Thresholding algorithm (FISTA), including two tuning-free variants from the literature. The proposed method is found to have a similar reconstruction quality and time to convergence as FISTA with an optimally tuned sparse weighting and offers substantial robustness and reconstruction quality improvements over competing tuning-free methods.

math.NA

Accelerated calibrationless parallel transmit mapping using joint transmit and receive low-rank tensor completion

Purpose: To evaluate an algorithm for calibrationless parallel imaging to reconstruct undersampled parallel transmit field maps for the body and brain. Methods: Using synthetic data, body, and brain measurements of relative transmit maps, three different approaches to a joint transmit-receive low-rank tensor completion algorithm are evaluated. These methods included: (i) virtual coils using the product of receive and transmit sensitivities, (ii) joint-receiver coils that enforces a low rank structure across receive coils of all transmit modes, and (iii) transmit low rank (TxLR) that uses a low rank structure for both receive and transmit modes simultaneously. The performance of each are investigated for different noise levels and different acceleration rates on an 8-channel parallel transmit 7T system. Results: The virtual coils method broke down with increasing noise levels or acceleration rates greater than two producing RMS error greater than 0.1. The joint receiver coils method worked well up to acceleration factors of four, beyond which the RMS error exceeded 0.1. While TxLR enabled an eight-fold acceleration with most RMS errors remaining below 0.1. Conclusion: This work demonstrates that under-sampling factors of up to eight-fold are feasible for transmit array mapping and can be reconstructed using calibrationless parallel imaging methods.

eess.IV

PEAR: PEriodic And fixed Rank separation for fast fMRI

In functional MRI (fMRI), faster acquisition via undersampling of data can improve the spatial-temporal resolution trade-off and increase statistical robustness through increased degrees-of-freedom. High quality reconstruction of fMRI data from undersampled measurements requires proper modeling of the data. We present an fMRI reconstruction approach based on modeling the fMRI signal as a sum of periodic and fixed rank components, for improved reconstruction from undersampled measurements. We decompose the fMRI signal into a component which a has fixed rank and a component consisting of a sum of periodic signals which is sparse in the temporal Fourier domain. Data reconstruction is performed by solving a constrained problem that enforces a fixed, moderate rank on one of the components, and a limited number of temporal frequencies on the other. Our approach is coined PEAR - PEriodic And fixed Rank separation for fast fMRI. Experimental results include purely synthetic simulation, a simulation with real timecourses and retrospective undersampling of a real fMRI dataset. Evaluation was performed both quantitatively and visually versus ground truth, comparing PEAR to two additional recent methods for fMRI reconstruction from undersampled measurements. Results demonstrate PEAR's improvement in estimating the timecourses and activation maps versus the methods compared against at acceleration ratios of R=8,16 (for simulated data) and R=6.66,10 (for real data). PEAR results in reconstruction with higher fidelity than when using a fixed-rank based model or a conventional Low-rank+Sparse algorithm. We have shown that splitting the functional information between the components leads to better modeling of fMRI, over state-of-the-art methods.

physics.med-ph