arXiv ScienceSearch

arXiv subjects

Maria Francesca Spadea

Publications and source records attributed to Maria Francesca Spadea.

9 recordsLinked to original sources

The Blind Spot in 2D Infants' Pose Estimation:Robust Learning from Noisy Annotations

Noisy annotations pose a significant challenge for supervised deep learning, as neural networks rely on large-scale, high-quality labeled data whose corruption can severely impair model performance. Although robustness to label noise has been extensively studied for classification tasks, it remains relatively underexplored in Pose Estimation (PE). This limitation becomes critical in clinical contexts, including neonatology, where PE of preterm infants is used to support the assessment of spontaneous motility, a key indicator of neurodevelopmental trajectories. In such settings, infants' images labeling is further hindered by visual challenges (e.g., keypoint self-occlusions, caregiver interference), making the annotation process inherently susceptible to errors. To tackle noisy annotations in PE, we introduce REliable keypoint selection via Memory of traINing Dynamics (REMIND), a clustering-based keypoint-selection strategy that exploits keypoint-wise training dynamics to identify noisy labels without assuming any prior knowledge of the noise distribution, thus enabling noise-free model training. When evaluated on the proprietary NeoPose dataset, comprising 46 videos of 46 preterm infants recorded in real clinical settings, REMIND correctly identifies noisy annotations across multiple corruption scenarios, achieving up to 93\% Area Under the Curve (AUC) with three different PE architectures used in the relevant literature. To our knowledge, this is the first study to explicitly address label noise in preterm infants' PE, paving the way for the design of trustworthy learning-based algorithms for infants'monitoring support when data quality cannot be guaranteed.

cs.CV

Energy-Efficient Federated Learning via Adaptive Encoder Freezing for MRI-to-CT Conversion: A Green AI-Guided Research

Federated Learning (FL) holds the potential to advance equality in health by enabling diverse institutions to collaboratively train deep learning (DL) models, even with limited data. However, the significant resource requirements of FL often exclude centres with limited computational infrastructure, further widening existing healthcare disparities. To address this issue, we propose a Green AI-oriented adaptive layer-freezing strategy designed to reduce energy consumption and computational load while maintaining model performance. We tested our approach using different federated architectures for Magnetic Resonance Imaging (MRI)-to-Computed Tomography (CT) conversion. The proposed adaptive strategy optimises the federated training by selectively freezing the encoder weights based on the monitored relative difference of the encoder weights from round to round. A patience-based mechanism ensures that freezing only occurs when updates remain consistently minimal. The energy consumption and CO2eq emissions of the federation were tracked using the CodeCarbon library. Compared to equivalent non-frozen counterparts, our approach reduced training time, total energy consumption and CO2eq emissions by up to 23%. At the same time, the MRI-to-CT conversion performance was maintained, with only small variations in the Mean Absolute Error (MAE). Notably, for three out of the five evaluated architectures, no statistically significant differences were observed, while two architectures exhibited statistically significant improvements. Our work aligns with a research paradigm that promotes DL-based frameworks meeting clinical requirements while ensuring climatic, social, and economic sustainability. It lays the groundwork for novel FL evaluation frameworks, advancing privacy, equity and, more broadly, justice in AI-driven healthcare.

cs.LG

Evidence-Based Text-Conditioned 3D CT Synthesis for Ovarian Cancer

Ovarian cancer is frequently diagnosed at an advanced stage, making preoperative contrast-enhanced computed tomography (CT) central to staging and surgical planning; yet the scarcity of annotated imaging data, compounded by privacy regulations, limits the development of generalizable computational models in this domain. Text-conditioned 3D CT synthesis has shown promise, but existing pipelines depend on paired radiology reports and have been evaluated only on chest CT. We propose OvESyn (Ovarian Evidence-based Synthesis), a framework that constructs standardized Findings and Impression sections directly from CT-derived imaging descriptors and routine clinical metadata, without any original radiology report, and uses them to condition a latent diffusion model adapted to 493 high-grade serous ovarian carcinoma patients. This is the first text-conditioned 3D CT synthesis framework adapted to an abdomino-pelvic oncologic setting. A systematic ablation over two adaptation axes, vision-language encoder alignment and generator fine-tuning, identifies generator domain adaptation as the operative mechanism for crossing the domain gap and establishing the target anatomy: without it, synthesis remains anchored to the thoracic pretraining domain, with Precision and Recall collapsing to zero and FID2.5D exceeding 140, regardless of encoder alignment. Encoder alignment instead refines intensity and fine detail. The full OvESyn attains the best distributional and intensity fidelity (FID2.5D 29.35, Precision 0.671, Wasserstein-1 0.044), while the generator-only variant maximizes coverage (Recall 0.645), reflecting a fidelity/coverage trade-off governed by encoder adaptation. Requiring only automatic segmentations and routine preoperative metadata, OvESyn supports transferability to report-scarce settings and provides a foundation for synthetic cohort generation in abdomino-pelvic oncologic imaging.

cs.CV

Vision Transformers for Preoperative CT-Based Prediction of Histopathologic Chemotherapy Response Score in High-Grade Serous Ovarian Carcinoma

Purpose. High-grade serous ovarian carcinoma (HGSOC) is characterized by pronounced biological and spatial heterogeneity and is frequently diagnosed at an advanced stage. Neoadjuvant chemotherapy (NACT) followed by delayed primary surgery is commonly employed in patients unsuitable for primary cytoreduction. The Chemotherapy Response Score (CRS) is a validated histopathological biomarker of response to NACT, but it is only available postoperatively. In this study, we investigate whether pre-treatment computed tomography (CT) imaging and clinical data can be used to predict CRS as an investigational decision-support adjunct to inform multidisciplinary team (MDT) discussions regarding expected treatment response. Methods. We proposed a 2.5D multimodal deep learning framework that processes lesion-dense omental slices using a pre-trained Vision Transformer encoder and integrates the resulting visual representations with clinical variables through an intermediate fusion module to predict CRS. Results. Our multimodal model, integrating imaging and clinical data, achieved a ROC-AUC of 0.95 alongside 95% accuracy and 80% precision on the internal test cohort (IEO, n=41 patients). On the external test set (OV04, n=70 patients), it achieved a ROC-AUC of 0.68, alongside 67% accuracy and 75% precision. Conclusion. These preliminary results demonstrate the feasibility of transformer-based deep learning for preoperative prediction of CRS in HGSOC using routine clinical data and CT imaging. As an investigational, pre-treatment decision-support tool, this approach may assist MDT discussions by providing early, non-invasive estimates of treatment response.

cs.CV

Dual-energy extraction for proton therapy and imaging: validation on a clinical synchrotron-based facility

The purpose of this study was to investigate the feasibility of extracting proton beams with two distinct energies within a single synchrotron cycle. The energy difference between the beams should be sufficient to use one beam as a range probe to guide the second therapeutic beam in a synchrotron-based proton therapy facility. A clinical synchrotron-based proton therapy facility with a maximum clinical energy of 250 megaeV (MeV) and an experimental energy capability of 330 MeV was used for the study. The synchrotron's internal diagnostic equipment, including beam orbit monitors, dipole magnetic field sensors, acceleration frequency monitors, and energy measurement devices, was used to characterize the properties of the beams within the synchrotron and during extraction. External dosimetric equipment included a PTW water tank fitted with two ionization chambers and an ionization chamber array. These were used to validate dual-energy extraction at the irradiation isocenter independently. Dual-energy extraction was demonstrated across three defined energy ranges: low (75-110 MeV), intermediate (120-155 MeV), and high (195-230 MeV). Both re-acceleration and de-acceleration modes were tested and validated. This preliminary study achieved an energy difference of 35 MeV between extracted beams across the three evaluated energy ranges. This corresponds to clinical targets used under standard operating conditions and does not require hardware modifications. Future studies should explore adjusting the control software to enable target switching during a single cycle or the use of suboptimal targets for higher-energy beams. This would allow for active, real-time range probing. Combining modified dual-energy extraction parameters with low-intensity extraction for high-energy beams shows great promise in enabling simultaneous proton imaging and therapy within a single synchrotron cycle.

physics.acc-ph

A Privacy-Preserving Federated Learning Framework for Generalizable CBCT to Synthetic CT Translation in Head and Neck

Shortened Abstract Cone-beam computed tomography (CBCT) has become a widely adopted modality for image-guided radiotherapy (IGRT). However, CBCT suffers from increased noise, limited soft-tissue contrast, and artifacts, resulting in unreliable Hounsfield unit values and hindering direct dose calculation. Synthetic CT (sCT) generation from CBCT addresses these issues, especially using deep learning (DL) methods. Existing approaches are limited by institutional heterogeneity, scanner-dependent variations, and data privacy regulations that prevent multi-center data sharing. To overcome these challenges, we propose a cross-silo horizontal federated learning (FL) approach for CBCT-to-sCT synthesis in the head and neck region, extending our FedSynthCT framework. A conditional generative adversarial network was collaboratively trained on data from three European medical centers in the public SynthRAD2025 challenge dataset. The federated model demonstrated effective generalization across centers, with mean absolute error (MAE) ranging from $64.38\pm13.63$ to $85.90\pm7.10$ HU, structural similarity index (SSIM) from $0.882\pm0.022$ to $0.922\pm0.039$, and peak signal-to-noise ratio (PSNR) from $32.86\pm0.94$ to $34.91\pm1.04$ dB. Notably, on an external validation dataset of 60 patients, comparable performance was achieved (MAE: $75.22\pm11.81$ HU, SSIM: $0.904\pm0.034$, PSNR: $33.52\pm2.06$ dB) without additional training, confirming robust generalization despite protocol, scanner differences and registration errors. These findings demonstrate the technical feasibility of FL for CBCT-to-sCT synthesis while preserving data privacy and offer a collaborative solution for developing generalizable models across institutions without centralized data sharing or site-specific fine-tuning.

physics.med-ph

FedSynthCT-Brain: A Federated Learning Framework for Multi-Institutional Brain MRI-to-CT Synthesis

The generation of Synthetic Computed Tomography (sCT) images has become a pivotal methodology in modern clinical practice, particularly in the context of Radiotherapy (RT) treatment planning. The use of sCT enables the calculation of doses, pushing towards Magnetic Resonance Imaging (MRI) guided radiotherapy treatments. Deep learning methods for MRI-to-sCT have shown promising results, but their reliance on single-centre training dataset limits generalisation capabilities to diverse clinical settings. Moreover, creating centralised multi-centre datasets may pose privacy concerns. To address the aforementioned issues, we introduced FedSynthCT-Brain, an approach based on the Federated Learning (FL) paradigm for MRI-to-sCT in brain imaging. This is among the first applications of FL for MRI-to-sCT, employing a cross-silo horizontal FL approach that allows multiple centres to collaboratively train a U-Net-based deep learning model. We validated our method using real multicentre data from four European and American centres, simulating heterogeneous scanner types and acquisition modalities, and tested its performance on an independent dataset from a centre outside the federation. In the case of the unseen centre, the federated model achieved a median Mean Absolute Error (MAE) of $102.0$ HU across 23 patients, with an interquartile range of $96.7-110.5$ HU. The median (interquartile range) for the Structural Similarity Index (SSIM) and the Peak Signal to Noise Ratio (PNSR) were $0.89 (0.86-0.89)$ and $26.58 (25.52-27.42)$, respectively. The analysis of the results showed acceptable performances of the federated approach, thus highlighting the potential of FL to enhance MRI-to-sCT to improve generalisability and advancing safe and equitable clinical applications while fostering collaboration and preserving data privacy.

eess.IV

LIMIS: Towards Language-based Interactive Medical Image Segmentation

Within this work, we introduce LIMIS: The first purely language-based interactive medical image segmentation model. We achieve this by adapting Grounded SAM to the medical domain and designing a language-based model interaction strategy that allows radiologists to incorporate their knowledge into the segmentation process. LIMIS produces high-quality initial segmentation masks by leveraging medical foundation models and allows users to adapt segmentation masks using only language, opening up interactive segmentation to scenarios where physicians require using their hands for other tasks. We evaluate LIMIS on three publicly available medical datasets in terms of performance and usability with experts from the medical domain confirming its high-quality segmentation masks and its interactive usability.

cs.CV

Deep learning-based synthetic-CT generation in radiotherapy and PET: a review

Recently, deep learning (DL)-based methods for the generation of synthetic computed tomography (sCT) have received significant research attention as an alternative to classical ones. We present here a systematic review of these methods by grouping them into three categories, according to their clinical applications: I) To replace CT in magnetic resonance (MR)-based treatment planning. II) Facilitate cone-beam computed tomography (CBCT)-based image-guided adaptive radiotherapy. III) Derive attenuation maps for the correction of positron emission tomography (PET). Appropriate database searching was performed on journal articles published between January 2014 and December 2020. The DL methods' key characteristics were extracted from each eligible study, and a comprehensive comparison among network architectures and metrics was reported. A detailed review of each category was given, highlighting essential contributions, identifying specific challenges, and summarising the achievements. Lastly, the statistics of all the cited works from various aspects were analysed, revealing the popularity and future trends, and the potential of DL-based sCT generation. The current status of DL-based sCT generation was evaluated, assessing the clinical readiness of the presented methods.

physics.med-ph