arXiv Science⌕ Search

arXiv subjects

M. van der Wild

Publications and source records attributed to M. van der Wild.

3 recordsLinked to original sources

Pushing the frontiers of low-frequency radio astronomy: An ultra-deep sub-arcsecond LOFAR image of ELAIS-N1

We present ultra-deep sub-arcsecond radio images of the ELAIS-N1 field covering 2.5x2.5 deg^2, produced from 200 hours of LOw Frequency ARray (LOFAR) observations in the 115-168 MHz band. The radio continuum images are obtained using recent advances in LOFAR long-baseline calibration and imaging. We achieve a central point-source sensitivity of 5.3 $μ$Jy/beam at an angular resolution of 0.33"x0.39" and an area-weighted sensitivity of 7.4 $μ$Jy/beam at 0.36"x0.45", making these the deepest radio images below 1.28 GHz to date and among the deepest at any radio frequency. By combining our data with previously released deep 6" LOFAR images, we compile a catalogue with a total of 62,916 unique radio sources across 2.5x2.5 deg^2. Our calibration strategy, combined with astrometric alignment using 95 Gaia quasars, results in positional offsets of $Δ$RA = -3 $\pm$ 27 mas and $Δ$DEC = 2 $\pm$ 17 mas for these same sources. We further demonstrate the potential for deep polarisation studies at sub-arcsecond resolution with instrumental leakages from Stokes I into linear polarisation down to 0.12%, which is about a factor of two better than the typical leakage in the LOFAR Two-metre Sky Survey at 6" resolution. Our results demonstrate that imaging a large number of observations over a wide field area at sub-arcsecond resolution is now computationally feasible. This establishes a new benchmark for low-frequency radio imaging in terms of combining depth, resolution, and survey area, which lays the foundation for deeper and wider surveys in the LOFAR2.0 and SKA era.

astro-ph.IM↗

Polarisation and Faraday rotation measure imaging at metre wavelengths with sub-arcsecond resolution: a foundational calibration strategy

Low-frequency radio polarimetric observations provide a powerful probe of magnetic fields in astrophysical sources and the intervening medium, as well as magnetospheric emission from compact objects such as pulsars, magnetically active stars, brown dwarfs, and planetary aurorae. With baselines of up to 2000 km, LOFAR offers a unique opportunity to study the low-frequency polarised Universe at sub-arcsecond resolution. However, polarimetric studies with LOFAR have so far been limited to angular resolutions of about 6 arcsec, resulting in stronger beam depolarisation. Here we present a calibration strategy that enables full-resolution polarimetric imaging with the LOFAR pan-European array. Our method applies full-Jones corrections to the international stations using an in-field unpolarised calibrator. In addition, when a sufficiently bright polarised source is present in the field, multi-epoch observations can be aligned in Faraday depth using a visibility-based correction that accounts for polarisation angle and rotation measure offsets. This approach enables deeper combined imaging and deconvolution. We apply this strategy to the LOFAR ELAIS-N1 field, combining four 8 h observations for a total integration time of 32 h. At 0.3 arcsec resolution, we detect two previously known polarised sources identified in lower-resolution studies, resolve additional polarised components, and localise emission regions with sub-arcsecond precision. We also identify a new polarised source and detect circularly polarised emission from the binary M-dwarf system CR Draconis, measuring its proper motion across epochs. These results demonstrate that sub-arcsecond polarimetry at metre wavelengths is now feasible with LOFAR, opening new science opportunities in the LOFAR2.0 era.

astro-ph.IM↗

Scalable and robust wide-field facet calibration with LOFAR's longest baselines

Recent work has successfully achieved sub-arcsecond wide-field imaging with high-band observations from the Low Frequency Array (LOFAR). However, the scalability of this work remains limited due to the need for manual intervention, poor calibration solutions for the Dutch LOFAR stations, and high computational costs. We address these issues by: (1) improving automated self-calibration using a signal-to-noise metric and a neural network for image artefact detection; (2) implementing a refined calibration strategy for the Dutch LOFAR stations; and (3) cutting computational costs by optimising the data processing strategy. We demonstrate the effectiveness of our automated processing strategy by reprocessing one previously reduced dataset and a new dataset from the ELAIS-N1 deep field, which features more severe ionospheric conditions. We find calibration artefacts across facet boundaries to be reduced with our improved automated calibration strategy and achieve a computational cost reduction of about a factor of 4 to 6 compared to previous work, where the exact factor depends on whether a single observation is processed or multiple observations of the same sky area are combined. Further optimisation and improved handling of data with baseline-dependent averaging could reduce this in the near future by another factor of two, bringing the total cost for an 8-hour observation below 30,000 CPU core hours. This work enables ultra-deep imaging at sensitivities on the order of a few $μ$Jy/beam. Furthermore, it also lays the foundation for a fully automated survey pipeline for sub-arcsecond wide-field imaging of the northern sky with LOFAR.

astro-ph.IM↗