arXiv ScienceSearch

arXiv subjects

M. Zuffa

Publications and source records attributed to M. Zuffa.

4 recordsLinked to original sources

FAMU: study of the energy dependent transfer rate $\Lambda_{\mu p \rightarrow \mu O}$

The main goal of the FAMU experiment is the measurement of the hyperfine splitting (hfs) in the 1S state of muonic hydrogen $\Delta E_{hfs}(\mu^-p)1S$. The physical process behind this experiment is the following: $\mu p$ are formed in a mixture of hydrogen and a higher-Z gas. When absorbing a photon at resonance-energy $\Delta E_{hfs}\approx0.182$~eV, in subsequent collisions with the surrounding $H_2$ molecules, the $\mu p$ is quickly de-excited and accelerated by $\sim2/3$ of the excitation energy. The observable is the time distribution of the K-lines X-rays emitted from the $\mu Z$ formed by muon transfer $(\mu p) +Z \rightarrow (\mu Z)^*+p$, a reaction whose rate depends on the $\mu p$ kinetic energy. The maximal response, to the tuned laser wavelength, of the time distribution of X-ray from K-lines of the $(\mu Z)^*$ cascade indicate the resonance. During the preparatory phase of the FAMU experiment, several measurements have been performed both to validate the methodology and to prepare the best configuration of target and detectors for the spectroscopic measurement. We present here the crucial study of the energy dependence of the transfer rate from muonic hydrogen to oxygen ($\Lambda_{\mu p \rightarrow \mu O}$), precisely measured for the first time.

nucl-ex

Steps towards the hyperfine splitting measurement of the muonic hydrogen ground state: pulsed muon beam and detection system characterization

The high precision measurement of the hyperfine splitting of the muonic-hydrogen atom ground state with pulsed and intense muon beam requires careful technological choices both in the construction of a gas target and of the detectors. In June 2014, the pressurized gas target of the FAMU experiment was exposed to the low energy pulsed muon beam at the RIKEN RAL muon facility. The objectives of the test were the characterization of the target, the hodoscope and the X-ray detectors. The apparatus consisted of a beam hodoscope and X-rays detectors made with high purity Germanium and Lanthanum Bromide crystals. In this paper the experimental setup is described and the results of the detector characterization are presented.

physics.ins-det

Characterization of the VEGA ASIC coupled to large area position-sensitive Silicon Drift Detectors

Low-noise, position-sensitive Silicon Drift Detectors (SDDs) are particularly useful for experiments in which a good energy resolution combined with a large sensitive area is required, as in the case of X-ray astronomy space missions and medical applications. This paper presents the experimental characterization of VEGA, a custom Application Specific Integrated Circuit (ASIC) used as the front-end electronics for XDXL-2, a large-area (30.5 cm^2) SDD prototype. The ASICs were integrated on a specifically developed PCB hosting also the detector. Results on the ASIC noise performances, both stand-alone and bonded to the large area SDD, are presented and discussed.

astro-ph.IM

Preliminary study of metabolic radiotherapy with 188Re via small animal imaging

188Re is a beta- (Emax = 2.12 MeV) and gamma (155 keV) emitter. Since its chemistry is similar to that of the largely employed tracer, 99mTc, molecules of hyaluronic acid (HA) have been labelled with 188Re to produce a target specific radiopharmaceutical. The radiolabeled compound, i.v. injected in healthy mice, is able to accumulate into the liver after a few minutes. To study the effect of metabolic radiotherapy in mice, we have built a small gamma camera based on a matrix of YAP:Ce crystals, with 0.6x0.6x10 mm**3 pixels, read out by a R2486 Hamamatsu PSPMT. A high-sensitivity 20 mm thick lead parallel-hole collimator, with hole diameter 1.5 mm and septa of 0.18 mm, is placed in front of the YAP matrix. Preliminary results obtained with various phantoms containing a solution of 188Re and with C57 black mice injected with the 188Re-HA solution are presented. To increase the space resolution and to obtain two orthogonal projections simultaneously we are building in parallel two new cameras to be positioned at 90 degrees. They use a CsI(Tl) matrix with 1x1x5 mm**3 pixels read out by H8500 Hamamatsu Flat panel PMT.

physics.med-ph