arXiv ScienceSearch

arXiv subjects

M. Soldani

Publications and source records attributed to M. Soldani.

At least 19 recordsLinked to original sources

Investigation of Radiation Emitted by Sub GeV Electrons in Oriented Scintillator Crystals

The research investigates coherent interactions between sub-GeV electrons and oriented scintillator crystals, leading to enhanced electromagnetic (EM) radiation. Experiments at Mainz Mikrotron (MAMI) involved PWO, BGO, and CsI crystals oriented along $\langle100\rangle$, $\langle111\rangle$, and $\langle100\rangle$ axes. Enhanced radiation emission was observed when the beam aligned with crystal axes, especially in BGO and CsI for the first time. These findings are crucial for innovative detectors using oriented crystal scintillators, amplifying EM processes along specific crystallographic directions. Potential applications include ultra-compact, highly sensitive electromagnetic calorimeters for high-energy physics and astroparticles, as well as high-performance gamma detectors for nuclear physics and medical imaging.

hep-ex

Beam Steering and Radiation Generation of Electrons in Bent Crystals in the Sub-GeV Domain

We present an investigation into beam steering and radiation emission by sub-GeV electrons traversing bent silicon crystals. Using 855, 600, and 300~MeV electron beams at the Mainz Microtron (MAMI), we explored orientational coherent effects and particle dynamics in a 15~$\mu$m-thick crystal bent along the (111) planes. Combined experimental and simulation analyses enabled the classification and quantitative assessment of the contributions from channeling, dechanneling, rechanneling, and volume capture to both beam deflection and radiation emission. Crystal steering remained effective even at 300~MeV, with measured channeling efficiencies exceeding 50\%, a record at such low energy. Channeling and volume reflection enhanced radiation emission by up to a factor of six compared to the misaligned orientation, highlighting strong orientational coherence effects in the sub-GeV regime. These findings confirm the feasibility of using bent crystals for efficient beam manipulation and high-intensity photon generation at low energies, supporting the development of novel light sources and beam control strategies at accelerator facilities operating in this energy range.

physics.acc-ph

R&D on a high-performance electromagnetic calorimeter based on oriented crystalline scintillators

Although inorganic scintillators are widely used in the design of electromagnetic calorimeters for high-energy physics and astrophysics, their crystalline nature and, hence, their lattice orientation are generally neglected in the detector design. However, in general, the features of the electromagnetic field experienced by the particles impinging on a crystal at a small angle with respect to a lattice axis affect their interaction mechanisms. In particular, in case of electrons/photons of $\mathcal{O} (10~\mathrm{GeV})$ or higher impinging on a high-$Z$ crystal at an angle of $\lesssim 1~\mathrm{mrad}$, the so-called strong field regime is attained: the bremsstrahlung and pair production cross sections are enhanced with respect to the case of amorphous or randomly oriented materials. Overall, the increase of these processes leads to an acceleration of the electromagnetic shower development. These effects are thoroughly investigated by the OREO (ORiEnted calOrimeter) team, and pave the way to the development of innovative calorimeters with a higher energy resolution, a higher efficiency in photon detection and an improved particle identification capabilities due to the relative boost of the electromagnetic interactions with respect to the hadronic ones. Moreover, a detector with the same resolution as the current state of the art and reduced thickness could be developed. An overview of the lattice effects at the foundation of the shower boost and of the current status of the development of an operational calorimeter prototype are presented. This concept could prove pivotal for both accelerator fixed-target experiments and satellite-borne $\gamma$-ray observatories.

physics.ins-det

A highly-compact and ultra-fast homogeneous electromagnetic calorimeter based on oriented lead tungstate crystals

Progress in high-energy physics has been closely tied to the development of highperformance electromagnetic calorimeters. Recent experiments have demonstrated the possibility to significantly accelerate the development of electromagnetic showers inside scintillating crystals typically used in homogeneous calorimeters based on scintillating crystals when the incident beam is aligned with a crystallographic axis to within a few mrad. In particular, a reduction of the radiation length has been measured when ultrarelativistic electron and photon beams were incident on a high-Z scintillator crystal along one of its main axes. Here, we propose the possibility to exploit this physical effect for the design of a new type of compact e.m. calorimeter, based on oriented ultrafast lead tungstate (PWO-UF) crystals, with a significant reduction in the depth needed to contain electromagnetic showers produced by high-energy particles with respect to the state-of-the-art. We report results from tests of the crystallographic quality of PWO-UF samples via high-resolution X-ray diffraction and photoelastic analysis. We then describe a proof-of-concept calorimeter geometry defined with a Geant4 model including the shower development in oriented crystals. Finally, we discuss the experimental techniques needed for the realization of a matrix of scintillator crystals oriented along a specific crystallographic direction. Since the angular acceptance for e.m. shower acceleration depends little on the particle energy, while the decrease of the shower length remains pronounced at very high energy, an oriented crystal calorimeter will open the way for applications at the maximum energies achievable in current and future experiments. Such applications span from forward calorimeters, to compact beam dumps for the search for light dark matter, to source-pointing space-borne {\gamma}-ray telescopes.

physics.ins-det

Experimental Study of Rare Kaon Decays at J-PARC with KOTO and KOTO II

The rare kaon decay $K_L\to\pi^0\nu\bar{\nu}$ is extremely sensitive to new physics, because the contribution to this decay in the Standard Model (SM) is highly suppressed and known very accurately; the branching ratio is $3\times 10^{-11}$ in the SM with a theoretical uncertainty of just 2%. The measurement of this branching ratio could provide essential new information about the flavor structure of the quark sector from the $s\to d$ transition. The decay is being searched for in the KOTO experiment at J-PARC, which has obtained the current best upper limit on the branching ratio of $2.2\times 10^{-9}$; a sensitivity to branching ratios below $10^{-10}$ is achievable by the end of the decade. A next-generation experiment at J-PARC, KOTO II, was proposed in 2024 with 82 members worldwide, including significant contributions from European members. The goal of KOTO II is to measure the $K_L\to\pi^0\nu\bar{\nu}$ branching ratio with sensitivity below $10^{-12}$ in the 2030s. Discovery of the decay with $5\sigma$ significance is achievable at the SM value of the branching ratio. An indication of new physics with a significance of 90% is possible if the observed branching ratio differs by 40% from the SM value. Another important goal of KOTO II is to measure the branching ratio of the unobserved $K_L\to \pi^0e^+e^-$ decay, which can give an input to flavor structures of new physics. Other rare $K_L$ decays and hidden-sector particles are also in the scope of the study. After 2026, KOTO will be the only dedicated rare kaon decay experiment in the world, and KOTO II is the only future rare kaon decay project currently proposed. We would like to lead a global initiative for the experimental study of rare kaon decays, with significant contributions and support from the European community.

hep-ex

Beam test, simulation, and performance evaluation of PbF$_2$ and PWO-UF crystals with SiPM readout for a semi-homogeneous calorimeter prototype with longitudinal segmentation

Crilin (Crystal Calorimeter with Longitudinal Information) is a semi-homogeneous, longitudinally segmented electromagnetic calorimeter based on high-$Z$, ultra-fast crystals with UV-extended SiPM readout. The Crilin design has been proposed as a candidate solution for both a future Muon Collider barrel ECAL and for the Small Angle Calorimeter of the HIKE experiment. As a part of the Crilin development program, we have carried out beam tests of small ($10\times10\times40$~mm$^3$) lead fluoride (PbF$_2$) and ultra-fast lead tungstate (PbWO$_4$, PWO) crystals with 120~GeV electrons at the CERN SPS to study the light yield, timing response, and systematics of light collection with a proposed readout scheme. For a single crystal of PbF$_2$, corresponding to a single Crilin cell, a time resolution of better than 25~ps is obtained for $>$3 GeV of deposited energy. For a single cell of \pwo, a time resolution of better than 45~ps is obtained for the same range of deposited energy. This timing performance fully satisfies the design requirements for the Muon Collider and HIKE experiments. Further optimizations of the readout scheme and crystal surface preparation are expected to bring further improvements.

physics.ins-det

Strong enhancement of electromagnetic shower development induced by high-energy photons in a thick oriented tungsten crystal

We have observed a significant enhancement in the energy deposition by $25$--$100~\mathrm{GeV}$ photons in a $1~\mathrm{cm}$ thick tungsten crystal oriented along its $\langle 111 \rangle$ lattice axes. At $100~\mathrm{GeV}$, this enhancement, with respect to the value observed without axial alignment, is more than twofold. This effect, together with the measured huge increase in secondary particle generation is ascribed to the acceleration of the electromagnetic shower development by the strong axial electric field. The experimental results have been critically compared with a newly developed Monte Carlo adapted for use with crystals of multi-$X_0$ thickness. The results presented in this paper may prove to be of significant interest for the development of high-performance photon absorbers and highly compact electromagnetic calorimeters and beam dumps for use at the energy and intensity frontiers.

hep-ex

HIKE, High Intensity Kaon Experiments at the CERN SPS

A timely and long-term programme of kaon decay measurements at a new level of precision is presented, leveraging the capabilities of the CERN Super Proton Synchrotron (SPS). The proposed programme is firmly anchored on the experience built up studying kaon decays at the SPS over the past four decades, and includes rare processes, CP violation, dark sectors, symmetry tests and other tests of the Standard Model. The experimental programme is based on a staged approach involving experiments with charged and neutral kaon beams, as well as operation in beam-dump mode. The various phases will rely on a common infrastructure and set of detectors.

hep-ex

A high-performance custom photodetection system to probe the light yield enhancement in oriented crystals

Scintillating homogeneous detectors represent the state of the art in electromagnetic calorimetry. Moreover, the currently neglected crystalline nature of the most common inorganic scintillators can be exploited to achieve an outstanding performance boost in terms of compactness and energy resolution. In fact, it was recently demonstrated by the AXIAL/ELIOT experiments that a strong reduction in the radiation length inside PWO, and a subsequent enhancement in the scintillation light emitted per unit thickness, are attained when the incident particle trajectory is aligned with a crystal axis within $\sim 1^\circ$. A SiPM-based system has been developed to directly probe this remarkable effect by measuring the scintillation light emitted by a PWO sample. The same concept could be applied to full-scale detectors that would feature a design significantly more compact than currently achievable and unparalleled resolution in the range of interest for present and future experiments.

physics.ins-det

Crystal-based pair production for a lepton collider positron source

An intense positron sources is a demanding element in the design of future lepton colliders. A crystal-based hybrid positron source could be an alternative to a more conventional scheme based on the electron conversion into positron in a thick amorphous target. The conceptual idea of the hybrid source is to have two separate objects, a photon radiator and a photon-to-positron converter target. In such a scheme an electron beam crosses a thin axially oriented crystal with the emission of a channeling radiation, characterized by a considerably larger amount of photons if compared to Bremsstrahlung. The net result is an increase in the number of produced positrons at the converter target. In this paper we present the results of a beam test conducted at the DESY TB 21 with 5.6 GeV electron beam and a crystalline tungsten radiator. Experimental data clearly highlight an increased production of photons and they are critically compared with the outcomes of novel method to simulate the number of radiated photons, showing a very good agreement. Strong of this, the developed simulation tool has been exploited to design a simple scheme for a positron source based on oriented crystal, demonstrating the advantages in terms of reduction of both deposited energy and the peak energy deposition density if compared to conventional sources. The presented work opens the way for a realistic and detailed design of a hybrid crystal-based positron source for future lepton colliders.

physics.acc-ph

Progress towards the first measurement of charm baryon dipole moments

Electromagnetic dipole moments of short-lived particles are sensitive to physics within and beyond the Standard Model of particle physics but have not been accessible experimentally to date. To perform such measurements it has been proposed to exploit the spin precession of channeled particles in bent crystals at the LHC. Progress that enables the first measurement of charm baryon dipole moments is reported. In particular, the design and characterization on beam of silicon and germanium bent crystal prototypes, the optimization of the experimental setup, and advanced analysis techniques are discussed. Sensitivity studies show that first measurements of $Λ_c^+$ and $Ξ_c^+$ baryon dipole moments can be performed in two years of data taking with an experimental setup positioned upstream of the LHCb detector.

hep-ex

First design of a crystal-based extraction of 6 GeV electrons for the DESY II Booster Synchrotron

A proof-of-principle experimental setup for the extraction of 6 GeV electrons from the DESY II Booster Synchrotron using the channeling effect in a bent crystal is elaborated. Various aspects of the experimental setup were investigated in detail, such as the particle beam dynamics during the extraction process, the manufacturing and characterization of bent crystals, and the detection of the extracted beam. In order to optimize the crystal geometry, the overall process of beam extraction was simulated, taking into account the influence of radiation energy losses. As result it is concluded that the multi-turn electron beam extraction efficiency can reach up to 16 %. In principle this crystal-based beam extraction technique can be applied at any electron synchrotron in order to provide multi-GeV electron beams in a parasitic mode. This technique will allow to supply fixed-target experiments by intense high-quality monoenergetic electron beams. Furthermore, electron/positron crystal-based extraction from future lepton colliders may provide an access to unique experimental conditions for ultra-high energy fixed-target experiments including searches for new physics beyond the Standard Model.

physics.acc-ph

Muon detection in electron-positron annihilation for muon collider studies

The investigation of the energy frontier in physics requires novel concepts for future colliders. The idea of a muon collider is very appealing since it would allow to study particle collisions at up to tens of TeV energy, while offering a cleaner experimental environment with respect to hadronic colliders. One key element in the muon collider design is the low-emittance muon production. Recently,the Low EMittance Muon Accelerator (LEMMA) collaboration has explored the muon pair production close to its kinematic threshold by annihilating 45 GeV positrons with electrons in a low Z material target. In this configuration, muons are emerging from the target with a naturally low-emittance. In this paper we describe the performance of a system, to study this production mechanism, that consists in several segmented absorbers with alternating active layers composed of fast Cherenkov detectors together with a muon identification technique based on this detector. Passive layers were made of tungsten. We collected data corresponding to muon and electron beams produced at the H2 line in the North Area of the European Organization for Nuclear Research (CERN) in September 2018.

physics.ins-det

Investigation on radiation generated by Sub-GeV electrons in ultrashort Si and Ge bent crystals

We report on the measurements of the spectra of gamma radiation generated by 855 MeV electrons in bent silicon and germanium crystals at MAMI (MAinzer MIkrotron). The crystals were 15 μm thick along the beam direction to ensure high deflection efficiency. Their (111) crystalline planes were bent by means of a piezo-actuated mechanical holder, which allowed to remotely change the crystal curvature. In such a way it was possible to investigate the radiation emitted under planar channeling and volume reflection as a function of the curvature of the crystalline planes. We show that using volume reflection, one can produce intense gamma radiation with comparable intensity but higher angular acceptance than for channeling. We studied the trade-off between radiation intensity and angular acceptance at different values of the crystal curvature. The measurements of radiation spectra have been carried out for the first time in bent Germanium crystals. In particular, the intensity of radiation in the Ge crystal is higher than in the Si one due to the higher atomic number, which is important for the development of the X-ray and gamma radiation sources based on higher-Z deformed crystals, such as crystalline undulator.

physics.acc-ph

The ENUBET Beamline

The ENUBET ERC project (2016-2021) is studying a narrow band neutrino beam where lepton production can be monitored at single particle level in an instrumented decay tunnel. This would allow to measure $ν_μ$ and $ν_{e}$ cross sections with a precision improved by about one order of magnitude compared to present results. In this proceeding we describe a first realistic design of the hadron beamline based on a dipole coupled to a pair of quadrupole triplets along with the optimisation guidelines and the results of a simulation based on G4beamline. A static focusing design, though less efficient than a horn-based solution, results several times more efficient than originally expected. It works with slow proton extractions reducing drastically pile-up effects in the decay tunnel and it paves the way towards a time-tagged neutrino beam. On the other hand a horn-based transferline would ensure higher yields at the tunnel entrance. The first studies conducted at CERN to implement the synchronization between a few ms proton extraction and a horn pulse of 2-10 ms are also described.

physics.acc-ph

Investigation on steering of ultrarelativistic $e^{\pm}$ beam through an axially oriented bent crystal

An investigation on stochastic deflection of high-energy charged particles in a bent crystal was carried out. In particular, we investigated the deflection efficiency under axial confinement of both positively and negatively charged particles as a function of the crystal orientation, the choice of the bending plane, and of the charge sign. Analytic estimations and numerical simulations were compared with dedicated experiments at the H4 secondary beam line of SPS North Area, with 120 GeV/$c$ electrons and positrons. In the work presented in this article, the optimal orientations of the plane of bending of the crystal, which allow deflecting the largest number of charged particles using a bent crystal in axial orientation, were found.

physics.acc-ph

Study of muon pair production from positron annihilation at threshold energy

The muon collider represents one of the most promising solutions for a future machine exploring the high energy frontier, but several challenges due to the 2.2 $μ$sec muon lifetime at rest have to be carefully considered. The LEMMA project is investigating the possibility of producing low emittance muon/antimuon pairs from the e$^+$e$^-$ annihilation process at threshold energy, resulting in small transverse emittance beams without any additional beam cooling. However most of the measurements available are performed at higher $\sqrt{s}$ values. It is therefore necessary to measure muons production in positron annihilation at threshold energy and compare the experimental results with the predictions in this specific energy regime. Apart from being a topic of physical interest by itself, these near to threshold measurements can have a sizeable impact on the estimation of the ultimate luminosity achievable in a muon collider with the LEMMA injection scheme.

hep-ex

KLEVER: An experiment to measure BR($K_L\toπ^0ν\barν$) at the CERN SPS

Precise measurements of the branching ratios for the flavor-changing neutral current decays $K\toπν\barν$ can provide unique constraints on CKM unitarity and, potentially, evidence for new physics. It is important to measure both decay modes, $K^+\toπ^+ν\barν$ and $K_L\toπ^0ν\barν$, since different new physics models affect the rates for each channel differently. The goal of the NA62 experiment at the CERN SPS is to measure the BR for the charged channel to within 10%. For the neutral channel, the BR has never been measured. We are designing the KLEVER experiment to measure BR($K_L\toπ^0ν\barν$) to $\sim$20% using a high-energy neutral beam at the CERN SPS starting in LHC Run 4. The boost from the high-energy beam facilitates the rejection of background channels such as $K_L\toπ^0π^0$ by detection of the additional photons in the final state. On the other hand, the layout poses particular challenges for the design of the small-angle vetoes, which must reject photons from $K_L$ decays escaping through the beam exit amidst an intense background from soft photons and neutrons in the beam. Background from $Λ\to nπ^0$ decays in the beam must also be kept under control. We present findings from our design studies for the beamline and experiment, with an emphasis on the challenges faced and the potential sensitivity for the measurement of BR($K_L\toπ^0ν\barν$).

hep-ex