arXiv ScienceSearch

arXiv subjects

M. Perry

Publications and source records attributed to M. Perry.

14 recordsLinked to original sources

Measurement of the muon flux at SNOLAB using the DEAP-3600 experiment

A direct measurement of the muon flux at SNOLAB is performed using the DEAP-3600 experiment, located 2 km underground at SNOLAB near Sudbury, Canada. Primarily designed for the direct detection of weakly interacting massive particles (WIMPs), a dark matter candidate, DEAP-3600 consists of an inner spherical acrylic vessel containing a liquid argon target; this vessel is enclosed within a steel shell which is submerged in an instrumented water tank, serving as a muon veto for the dark matter search. The muon flux measurement is performed using a cut-and-count analysis of events observed in the muon veto detector and of events which are coincident between the muon veto and the liquid argon target. The requirement that muons traverse both the water and liquid argon minimizes instrumental backgrounds and systematic uncertainties. Using data collected from November 2016 to March 2020, the muon flux is measured by this coincidence analysis to be $(3.71 \pm 0.25_{\textrm{stat}} \pm 0.09_{\textrm{sys}}) \times 10^{-10}\, \mu/$cm$^2$/s. The standalone measurement using muon veto data only is compatible within uncertainties. Both measurements agree with the previous result by the SNO experiment and with simulations carried out using the MUTE software. These results provide an important benchmark for future rare-event searches at the SNOLAB facility.

hep-ex

First evidence of neutrino absorption on argon using $^{8}$B solar neutrinos in DEAP-3600

We report experimental evidence for electron neutrino charged-current interactions (neutrino absorption, CC $\nu_e$) from $^{8}$B solar neutrinos on $^{40}$Ar using an exposure of ($7.29 \pm 0.05$) tonne$\cdot$years in the DEAP-3600 detector. A region of interest (ROI) of 10.5-13.0 MeV reconstructed energy calibrated on single-peak events, corresponding to incident neutrino energy in 12.0-14.5 MeV, is used for this measurement. We observe 5 single-peak and 1 double-peak neutrino-like events consistent with the $^{8}$B solar neutrino energy spectrum in the ROI after correcting for nonlinearities in the detector response at high energies. With an expected background of $0.48~^{+0.16}_{-0.15}$ events, the data correspond to a significance of $4.0\,\sigma$ with respect to the background-only hypothesis. We report an energy-averaged cross section of $(4.0~^{+2.0}_{-1.6}~\mathrm{(stat)}~^{+0.8}_{-0.7}~\mathrm{(sys)})\times 10^{-41}\,\mathrm{cm}^2$ in the ROI for the CC $\nu_{e}$ signal, a factor $(2.4~^{+1.3}_{-1.0})$ higher than predicted by Bhattacharya, Goodman and Garc\'ia (2009).

hep-ex

A radon emanation measurement system at the Carleton Noble Liquid Detector Laboratory

Radon is one of the most important sources of background in rare event search experiments, such as those searching for Dark Matter and neutrinos, due to its unavoidable production from natural uranium. In low-background experiments, radon emanation from detector materials and components accounts for a major portion of contamination. To investigate this, a radon detection system was developed at the Carleton nOble Liquid Detector Laboratory (COLD Lab). The setup consists of a stainless steel emanation chamber, a low-background ZnS(Ag) cell, and an assembly for radon transfer and collection. This setup was used to study radon emanation from materials under vacuum conditions. Additionally, a charcoal trap made of activated charcoal and equipped with a flow meter was constructed to study radon levels in nitrogen gas and the residual radon in the gas filter used in the DEAP-3600 processing system. The radon concentration in the glove box, where critical DEAP-3600 internal detector components were completed, was also calculated based on these measurements. Now calibrated and in-use, the COLD lab radon emanation counter is an essential diagnostic tool for reducing backgrounds in future rate-event search experiments.

physics.ins-det

Dark Matter Search with the DEAP-3600 Detector using the Profile Likelihood Ratio Method

We present here a search for WIMP dark matter using 790.8 live-days of data collected with 3269 kg of liquid argon (1266 kg fiducial) by the DEAP-3600 detector at SNOLAB, using the Profile Likelihood Ratio method. The likelihood model is based on three parameters: estimated energy, pulse-shape discrimination parameter, and reconstructed position within the detector. Using this method, the expected signal sensitivity of DEAP-3600 benefits from an increased fiducial volume and improved event selection acceptance. Alpha-decays from a small number of dust particulates circulating within the liquid argon target are the dominant source of background events and limit the sensitivity of this search. This result provides improved exclusion upper limits on the WIMP-nucleon spin-independent cross section on liquid argon for WIMP masses between 20 GeV/$c^{2}$ and 100 GeV/$c^{2}$. At 100 GeV/$c^{2}$ the observed limit is 3.4 $\times$ 10$^{-45}$ cm$^2$ at 90% confidence level.

hep-ex

Diffusion of $^{210}\text{Pb}$ and $^{210}\text{Po}$ in Nylon

Radon and its progeny constitute a major source of background in rare-event physics experiments, such as those searching for dark matter, neutrinos, and neutrinoless double beta decay, due to their origin as unavoidable decay products of natural uranium. In particular, $^{222}$Rn and its long-lived daughter $^{210}$Pb can diffuse from detector material surfaces, resulting in sustained background contributions. To investigate this process, a system was developed using a controlled radon source, a vacuum chamber with a high electric field, and a thin Nylon-6 film to enable deposition of radon progeny onto the film surface. Nylon-6 was selected for the initial measurement given its history in low-background experiments. We intend to systematically study diffusion in various polymers in the future. Our setup allowed for controlled study of the diffusion behavior of $^{210}$Pb and its daughter $^{210}$Po under varying humidity conditions. Our results show that both $^{210}$Pb and $^{210}$Po diffuse significantly in nylon under high relative humidity, which can potentially lead to internal contamination and increased background in low-background detectors. The diffusivity of $^{210}$Pb was found to be lower than 1.14 $\times$ 10$^{-15}$ cm$^2$/s at 40$\%$ relative humidity (RH), and to be (4.03 $\pm$ 1.01) $\times$ 10$^{-13}$ cm$^2$/s at 95$\%$ RH. The diffusivity of $^{210}$Po at 95$\%$ RH was measured to be (3.94 $\pm$ 0.98) $\times$ 10$^{-13}$ cm$^2$/s. These findings underscore the importance of controlling environmental humidity and material exposure to radon in the design of ultra-low background experiments.

hep-ex

QSHS: An Axion Dark Matter Resonant Search Apparatus

We describe a resonant cavity search apparatus for axion dark matter constructed by the Quantum Sensors for the Hidden Sector (QSHS) collaboration. The apparatus is configured to search for QCD axion dark matter, though also has the capability to detect axion-like particles (ALPs), dark photons, and some other forms of wave-like dark matter. Initially, a tuneable cylindrical oxygen-free copper cavity is read out using a low noise microwave amplifier feeding a heterodyne receiver. The cavity is housed in a dilution refrigerator and threaded by a solenoidal magnetic field, nominally 8T. The apparatus also houses a magnetic field shield for housing superconducting electronics, and several other fixed-frequency resonators for use in testing and commissioning various prototype quantum electronic devices sensitive at a range of axion masses in the range 2.0 to 40 micro-eV/c2. The apparatus as currently configured is intended as a test stand for electronics over the relatively wide frequency band attainable with the TM010 cavity mode used for axion searches. We present performance data for the resonator, dilution refrigerator, and magnet, and plans for the first science run.

physics.ins-det

Direct Measurement of the $^{39}$Ar Half-life from 3.4 Years of Data with the DEAP-3600 Detector

The half-life of $^{39}$Ar is measured using the DEAP-3600 detector located 2 km underground at SNOLAB. Between 2016 and 2020, DEAP-3600 used a target mass of (3269 $\pm$ 24) kg of liquid argon distilled from the atmosphere in a direct-detection dark matter search. Such an argon mass also enables direct measurements of argon isotope properties. The decay of $^{39}$Ar in DEAP-3600 is the dominant source of triggers by two orders of magnitude, ensuring high statistics and making DEAP-3600 well-suited for measuring this isotope's half-life. Use of the pulse-shape discrimination technique in DEAP-3600 allows powerful discrimination between nuclear recoils and electron recoils, resulting in the selection of a clean sample of $^{39}$Ar decays. Observing over a period of 3.4 years, the $^{39}$Ar half-life is measured to be $(302 \pm 8_{\rm stat} \pm 6_{\rm sys})$ years. This new direct measurement suggests that the half-life of $^{39}$Ar is significantly longer than the accepted value, with potential implications for measurements using this isotope's half-life as input.

nucl-ex

Relative Measurement and Extrapolation of the Scintillation Quenching Factor of $\alpha$-Particles in Liquid Argon using DEAP-3600 Data

The knowledge of scintillation quenching of $\alpha$-particles plays a paramount role in understanding $\alpha$-induced backgrounds and improving the sensitivity of liquid argon-based direct detection of dark matter experiments. We performed a relative measurement of scintillation quenching in the MeV energy region using radioactive isotopes ($^{222}$Rn, $^{218}$Po and $^{214}$Po isotopes) present in trace amounts in the DEAP-3600 detector and quantified the uncertainty of extrapolating the quenching factor to the low-energy region.

physics.ins-det

The LHCb VELO Upgrade Module Construction

The LHCb detector has undergone a major upgrade for LHC Run 3. This Upgrade I detector facilitates operation at higher luminosity and utilises full-detector information at the LHC collision rate, critically including the use of vertex information. A new vertex locator system, the VELO Upgrade, has been constructed. The core element of the new VELO are the double-sided pixelated hybrid silicon detector modules which operate in vacuum close to the LHC beam in a high radiation environment. The construction and quality assurance tests of these modules are described in this paper. The modules incorporate 200 \mum thick, n-on-p silicon sensors bump-bonded to 130 \nm technology ASICs. These are attached with high precision to a silicon microchannel substrate that uses evaporative CO$_2$ cooling. The ASICs are controlled and read out with flexible printed circuits that are glued to the substrate and wire-bonded to the chips. The mechanical support of the module is given by a carbon fibre plate, two carbon fibre rods and an aluminium plate. The sensor attachment was achieved with an average precision of 21 $\mathrm{\mu m}$, more than 99.5\% of all pixels are fully functional, and a thermal figure of merit of 3 \mathrm{Kcm^{2}W^{-1}}$ was achieved. The production of the modules was successfully completed in 2021, with the final assembly and installation completed in time for data taking in 2022.

physics.ins-det

First direct detection constraints on Planck-scale mass dark matter with multiple-scatter signatures using the DEAP-3600 detector

Dark matter particles with Planck-scale mass ($\simeq10^{19}\text{GeV}/c^2$) arise in well-motivated theories and could be produced by several cosmological mechanisms. Using a blind analysis of data collected over a 813 d live time with DEAP-3600, a 3.3 t single-phase liquid argon-based dark matter experiment at SNOLAB, a search for supermassive dark matter was performed, looking for multiple-scatter signals. No candidate signal events were observed, leading to the first direct detection constraints on Planck-scale mass dark matter. Leading limits constrain dark matter masses between $8.3\times10^{6}$ and $1.2\times10^{19} \text{GeV}/c^2$, and cross sections for scattering on $^{40}$Ar between $1.0\times10^{-23}$ and $2.4\times10^{-18} \text{cm}^2$. These are used to constrain two composite dark matter models.

astro-ph.CO

Pulseshape discrimination against low-energy Ar-39 beta decays in liquid argon with 4.5 tonne-years of DEAP-3600 data

The DEAP-3600 detector searches for the scintillation signal from dark matter particles scattering on a 3.3 tonne liquid argon target. The largest background comes from $^{39}$Ar beta decays and is suppressed using pulseshape discrimination (PSD). We use two types of PSD algorithm: the prompt-fraction, which considers the fraction of the scintillation signal in a narrow and a wide time window around the event peak, and the log-likelihood-ratio, which compares the observed photon arrival times to a signal and a background model. We furthermore use two algorithms to determine the number of photons detected at a given time: (1) simply dividing the charge of each PMT pulse by the charge of a single photoelectron, and (2) a likelihood analysis that considers the probability to detect a certain number of photons at a given time, based on a model for the scintillation pulseshape and for afterpulsing in the light detectors. The prompt-fraction performs approximately as well as the log-likelihood-ratio PSD algorithm if the photon detection times are not biased by detector effects. We explain this result using a model for the information carried by scintillation photons as a function of the time when they are detected.

physics.ins-det

A Novel Electrical Method to Measure Wire Tensions for Time Projection Chambers

We present a novel electrical technique to measure the tension of wires in multi-wire drift chambers. We create alternating electric fields by biasing adjacent wires on both sides of a test wire with a superposition of positive and negative DC voltages on an AC signal ($V_{\rm AC} \pm V_{\rm DC}$). The resulting oscillations of the wire will display a resonance at its natural frequency, and the corresponding change of the capacitance will lead to a measurable current. This scheme is scalable to multiple wires and therefore enables us to precisely measure the tension of a large number of wires in a short time. This technique can also be applied at cryogenic temperatures making it an attractive solution for future large time-projection chambers such as the DUNE detector. We present the concept, an example implementation and its performance in a real-world scenario and discuss the limitations of the sensitivity of the system in terms of voltage and wire length.

physics.ins-det

DEM L241, a Supernova Remnant containing a High-Mass X-ray Binary

A Chandra observation of the Large Magellanic Cloud supernova remnant DEM L241 reveals an interior unresolved source which is probably an accretion-powered binary. The optical counterpart is an O5III(f) star making this a High-Mass X-ray Binary (HMXB) with orbital period likely to be of order tens of days. Emission from the remnant interior is thermal and spectral information is used to derive density and mass of the hot material. Elongation of the remnant is unusual and possible causes of this are discussed. The precursor star probably had mass > 25 solar masses

astro-ph.HE

Competition between normal and intruder states inside the "Island of Inversion"

The beta decay of the exotic 30Ne (N=20) is reported. For the first time, the low-energy level structure of the N=19, 30Na (Tz = 4), is obtained from beta-delayed gamma spectroscopy using fragment-beta-gamma-gamma coincidences. The level structure clearly displays "inversion", i.e., intruder states with mainly 2p2h configurations displacing the normal states to higher excitation energies. The good agreement in excitation energies and the weak and electromagnetic decay patterns with Monte Carlo Shell Model calculations with the SDPF-M interaction in the sdpf valence space illustrates the small d3/2 - f7/2 shell gap. The relative position of the "normal dominant" and "intruder dominant" excited states provides valuable information to understand better the N=20 shell gap.

nucl-ex