arXiv ScienceSearch

arXiv subjects

M. Kitaguchi

Publications and source records attributed to M. Kitaguchi.

At least 19 recordsLinked to original sources

A New High-Intensity Source for Ultracold Neutrons

The TRIUMF UltraCold Advanced Neutron (TUCAN) collaboration has completed a new superthermal source for ultracold neutrons (UCNs) at TRIUMF. It uses neutrons from a spallation target driven by TRIUMF's %520-MeV main cyclotron. Heavy water and liquid deuterium serve as neutron moderators, and inelastic scattering inside superfluid $^4$He at around \qty{1.1}{\kelvin} slows the neutrons down to become ultracold. During commissioning runs with the completed source, including the deuterium moderator, up to $1.47(2)\times 10^7$ UCNs were detected in the experimental area after irradiating the target and accumulating UCNs in the source for \qty{60}{\second}. Up to \qty{6.75(3)e5} UCN/s were detected during continuous operation, more than at any other source in the world.

physics.ins-det

Development of a Modular Current-Mode NaI(Tl) Detector Array for Parity Odd (n,{\gamma}) Cross Section Measurements

The Neutron Optics Parity and Time-Reversal Violation Experiment (NOPTREX) Collaboration has developed a modular array of 24 NaI(Tl) detectors to measure parity and time-reversal symmetry violation in neutron-nucleus interactions. These detectors feature custom electronics that allow for operation in pulse or current mode. This paper describes the design, construction, characterization, and testing of the detectors in this array. We demonstrate the ability of the array to detect parity-odd asymmetries in neutron resonances by observing the known 0.7 eV parity-violating resonance in 139La in measurements at LANSCE.

physics.ins-det

Ultracold Neutron Guide-Coating Facility at U.Winnipeg

We report the construction and commissioning of a new ultracold neutron (UCN) guide-coating facility at the University of Winnipeg. The facility employs pulsed laser deposition (PLD) to produce diamond-like carbon (DLC) coatings on cylindrical UCN guides up to 1 m in length with a 200 mm outer diameter. DLC is a promising material for UCN transport and storage due to its high real component of the optical potential, low neutron absorption cross section, and low depolarization probabilities. First coating attempts on a full length aluminum UCN guide and matching blank flange were successfully coated with a carbon film with density of 2.3 g/cm$^3$, corresponding to optical potentials of 200 neV, as measured by X-ray reflectometry (XRR). Coating thicknesses were measured to be 90 nm for the UCN guide and 180 nm for the flange with no evidence of delamination. The implementation of a plasma plume collimator and plasma feed back control via a time of flight in vacuum ion probe produced a film with an XRR measured density of 2.8 g/cm$^3$, corresponding to an optical potential of 240 neV. This 80 nm thick film had poor adhesion to the aluminum tube substrate. These results establish a baseline for the coating facility. Ongoing and future work focuses on improving the diamond content of films and adhesion through plasma plume collimation, TOF ion probe feed back, and pre/post treatment methods with the goal of providing high quality DLC UCN guides for the TUCAN experiment at TRIUMF.

physics.ins-det

Initial results of the TRIUMF ultracold advanced neutron source

We report the first results on ultracold neutron production from a new spallation-driven superfluid $^4$He (He-II) source at TRIUMF, which is being prepared for a new, precise measurement of the neutron electric dipole moment. A total of $(9.3 \pm 0.8)\times 10^{5}$ ultracold neutrons were observed at a proton beam current of \SI{37}{\uA}, when the target was irradiated for a period of \SI{60}{\s}. The results are in fair agreement with expectations based on a detailed simulation of neutron transport and ultracold neutron source cryogenics. There is some indication that the new source might not be as limited by the conduction of heat through the He-II as originally expected. The results indicate that the source is likely to make its ultimate production goals, once the liquid deuterium cold moderator system is completed, with the expectation that $5.7\times 10^7$~UCNs would be detected in the same experiment with full liquid levels. This would, for example, correspond to delivery of $1.4\times 10^6$~UCNs delivered to each of two nEDM measurement cells, and a statistical uncertainty of $1\times 10^{-27}~e$cm on the neutron EDM in 280 days of running.

nucl-ex

Neutron EDM Experiment with an Advanced Ultracold Neutron Source at TRIUMF

The TRIUMF Ultracold Advanced Neutron (TUCAN) collaboration has been developing a high-intensity ultracold neutron (UCN) source aimed at searching for the neutron electric dipole moment (EDM) with a sensitivity goal of $10^{-27}\ e{\rm cm}$. This article reports on recent progress in commissioning of the UCN source and in the development of the neutron EDM spectrometer. In its final configuration, the accelerator-driven super-thermal UCN source will enable a neutron EDM experiment with two orders of magnitude improved statistics compared to the current best experiment. Substantial progress in 2024 allowed the collaboration to operate the complete source system, with the exception of the liquid deuterium cold moderator, resulting in the first production of UCNs. The status of the EDM spectrometer is also presented, with emphasis on UCN handling components and magnetic subsystems relevant to field control, shielding, and magnetometry.

physics.ins-det

Fundamental Nuclear and Particle Physics At Neutron Sources

Fundamental neutron and neutrino physics at neutron sources, combining precision measurements and theory, can probe new physics at energy scales well beyond the highest energies probed by the LHC and possible future high energy collider facilities. The European Spallation Source (ESS) will in the not too far future be a most powerful pulsed neutron source and simultaneously the world's brightest pulsed neutrino source. The ESS, and neutron sources in general, can provide unprecedented and unique opportunities to contribute to the search for the missing elements in the Standard Model of particle physics. Currently there are no strong indications where hints of the origin of the new physics will emerge. A multi-pronged approach will provide the fastest path to fill the gaps in our knowledge and neutron sources have a pivotal role to play. To survey the ongoing and proposed physics experiments at neutron sources and assess their potential impact, a workshop was held at Lund University in January, 2025. This report is a summary of that workshop and has been prepared as input to the European Strategy Update.

nucl-ex

Cryogenic systems for the TUCAN EDM experiment

The TUCAN (TRIUMF UltraCold Advanced Neutron) Collaboration is completing a new ultracold neutron (UCN) source. The UCN source will deliver UCNs to a neutron electric dipole moment (EDM) experiment. The EDM experiment is projected to be capable of an uncertainty of $1\times 10^{-27}~e$cm, competitive with other planned projects, and a factor of ten more precise than the present world's best. The TUCAN source is based on a UCN production volume of superfluid helium (He-II), held at 1~K, and coupled to a proton-driven spallation target. The production rate in the source is expected to be in excess of $10^7$~UCN/s; since UCN losses can be small in superfluid helium, this should allow us to build up a large number of UCNs. The spallation-driven superfluid helium technology is the principal aspect making the TUCAN project unique. The superfluid production volume was recently cooled, for the first time, and successfully filled with superfluid helium. The design principles of the UCN source are described, along with some of the challenging cryogenic milestones that were recently passed.

physics.ins-det

Improved measurements of neutron lifetime with cold neutron beam at J-PARC

The ``neutron lifetime puzzle'' arises from the discrepancy between neutron lifetime measurements obtained using the beam method, which measures decay products, and the bottle method, which measures the disappearance of neutrons. To resolve this puzzle, we conducted an experiment using a pulsed cold neutron beam at J-PARC. In this experiment, the neutron lifetime is determined from the ratio of neutron decay counts to $^3$He(n,p)$^3$H reactions in a gas detector. This experiment belongs to the beam method but differs from previous experiments that measured protons, as it instead detects electrons, enabling measurements with distinct systematic uncertainties. By enlarging the beam transport system and reducing systematic uncertainties, we achieved a fivefold improvement in precision. Analysis of all acquired data yielded a neutron lifetime of $\tau_{\rm n}=877.2~\pm~1.7_{\rm(stat.)}~^{+4.0}_{-3.6}{}_{\rm (sys.)}$ s. This result is consistent with bottle method measurements but exhibits a 2.3$\sigma$ tension with the average value obtained from the proton-detection-based beam method.

nucl-ex

Circular polarization measurement for individual gamma rays in capture reactions with intense pulsed neutrons

Measurements of circular polarization of $\gamma$-ray emitted from neutron capture reactions provide valuable information for nuclear physics studies. The spin and parity of excited states can be determined by measuring the circular polarization from polarized neutron capture reactions. Furthermore, the $\gamma$-ray circular polarization in a neutron capture resonance is crucial for studying the enhancement effect of parity nonconservation in compound nuclei. The $\gamma$-ray circular polarization can be measured using a polarimeter based on magnetic Compton scattering. A polarimeter was constructed, and its performance indicators were evaluated using a circularly polarized $\gamma$-ray beam. Furthermore, as a demonstration, the $\gamma$-ray circular polarization was measured in $^{32}$S($\vec{\textrm{n}}$,$\gamma$)$^{33}$S reactions with polarized neutrons.

physics.ins-det

Transverse asymmetry of individual $\gamma$-rays in the $^{139}$La($\vec{n}$, $\gamma$)$^{140}$La reaction

The enhancement of the parity-violating asymmetry in the vicinity of $p$-wave compound nuclear resonances was observed for a variety of medium-heavy nuclei. The enhanced parity-violating asymmetry can be understood using the $s$-$p$ mixing model. The $s$-$p$ mixing model predicts several neutron energy-dependent angular correlations between the neutron momentum $\vec k_n$, neutron spin $\vec\sigma_n$, $\gamma$-ray momentum $\vec k_\gamma$, and $\gamma$-ray polarization $\vec\sigma_\gamma$ in the $(n,\gamma)$ reaction. In this paper, the improved value of the transverse asymmetry of $\gamma$-ray emissions, corresponding to a correlation term $\vec{\sigma}_n\cdot(\vec k_n\times\vec k_\gamma)$ in the $^{139}\mathrm{La}(\vec n,\gamma)^{140}\mathrm{La}$ reaction, and the transverse asymmetries in the transitions to several low excited states of $^{140}\mathrm{La}$ are reported.

nucl-ex

Performance of the Fully-equipped Spin Flip Chopper For Neutron Lifetime Experiment at J-PARC

To solve the ''neutron lifetime puzzle,'' where measured neutron lifetimes differ depending on the measurement methods, an experiment with pulsed neutron beam at J-PARC is in progress. In this experiment, neutrons are bunched into 40-cm lengths using a spin flip chopper (SFC), where the statistical sensitivity was limited by the aperture size of the SFC. The SFC comprises three sets of magnetic supermirrors and two resonant spin flippers. In this paper, we discuss an upgrade to enlarge the apertures of the SFC. With this upgrade, the statistics per unit time of the neutron lifetime experiment increased by a factor of 2.8, while maintaining a signal-to-noise ratio of 250-400 comparable to the previous one. Consequently, the time required to reach a precision of 1 s in the neutron lifetime experiment was reduced from 590 to 170 days, which is a significant reduction in time. This improvement in statistic will also contribute to the reduction of systematic uncertainties, such as background evaluation, fostering further advancements in the neutron lifetime experiments at J-PARC.

physics.ins-det

High sensitivity of a future search for P-odd/T-odd interactions on the 0.75 eV $p$-wave resonance in $\vec{n}+^{139}\vec{\rm La}$ forward transmission determined using pulsed neutron beam

Neutron transmission experiments can offer a new type of highly sensitive search for time-reversal invariance violating (TRIV) effects in nucleon-nucleon interactions via the same enhancement mechanism observed for large parity violating (PV) effects in neutron-induced compound nuclear processes. In these compound processes, the TRIV cross-section is given as the product of the PV cross-section, a spin-factor $\kappa$, and a ratio of TRIV and PV matrix elements. We determined $\kappa$ to be $0.59\pm0.05$ for $^{139}$La+$n$ using both $(n, \gamma)$ spectroscopy and ($\vec{n}+^{139}\vec{\rm La}$) transmission. This result quantifies for the first time the high sensitivity of the $^{139}$La 0.75~eV $p$-wave resonance in a future search for P-odd/T-odd interactions in ($\vec{n}+^{139}\vec{\rm La}$) forward transmission.

nucl-ex

Spin dependence in the $p$-wave resonance of ${^{139}\vec{\rm{La}}+\vec{n}}$

We measured the spin dependence in a neutron-induced $p$-wave resonance by using a polarized epithermal neutron beam and a polarized nuclear target. Our study focuses on the 0.75~eV $p$-wave resonance state of $^{139}$La+$n$, where largely enhanced parity violation has been observed. We determined the partial neutron width of the $p$-wave resonance by measuring the spin dependence of the neutron absorption cross section between polarized $^{139}\rm{La}$ and polarized neutrons. Our findings serve as a foundation for the quantitative study of the enhancement effect of the discrete symmetry violations caused by mixing between partial amplitudes in the compound nuclei.

nucl-ex

Improved Measurements of Muonic Helium Ground-State Hyperfine Structure at a Near-Zero Magnetic Field

Muonic helium atom hyperfine structure (HFS) measurements are a sensitive tool to test the three-body atomic system and bound-state quantum electrodynamics theory, and determine fundamental constants of the negative muon magnetic moment and mass. The world's most intense pulsed negative muon beam at the Muon Science Facility of the Japan Proton Accelerator Research Complex allows improvement of previous measurements and testing further $CPT$ invariance by comparing the magnetic moments and masses of positive and negative muons (second-generation leptons). We report new ground-state HFS measurements of muonic helium-4 atoms at a near-zero magnetic field, performed for the first time using a small admixture of CH$_{4}$ as an electron donor to form neutral muonic helium atoms efficiently. Our analysis gives $\Delta\nu$ = 4464.980(20) MHz (4.5 ppm), which is more precise than both previous measurements at weak and high fields. The muonium ground-state HFS was also measured under the same conditions to investigate the isotopic effect on the frequency shift due to the gas density dependence in He with CH$_{4}$ admixture and compared with previous studies. Muonium and muonic helium can be regarded as light and heavy hydrogen isotopes with an isotopic mass ratio of 36. No isotopic effect was observed within the current experimental precision.

physics.atom-ph

A diffuse scattering model of ultracold neutrons on wavy surfaces

Metal tubes plated with nickel-phosphorus are used in many fundamental physics experiments using ultracold neutrons (UCN) because of their ease of fabrication. These tubes are usually polished to a average roughness of 25-150 nm. However, there is no scattering model that accurately describes UCN scattering on such a rough guide surface with a mean-square roughness larger than 5 nm. We therefore developed a scattering model for UCN in which scattering from random surface waviness with a size larger than the UCN wavelength is described by a microfacet Bidirectional Reflectance Distribution Function model (mf-BRDF model), and scattering from smaller structures by the Lambert's cosine law (Lambert model). For the surface waviness, we used the statistical distribution of surface slope measured by an atomic force microscope on a sample piece of guide tube as input of the model. This model was used to describe UCN transmission experiments conducted at the pulsed UCN source at J-PARC. In these experiments, a UCN beam collimated to a divergence angle smaller than $\pm 6^{\circ}$ was directed into a guide tube with a mean-square roughness of 6.4 nm to 17 nm at an oblique angle, and the UCN transport performance and its time-of-flight distribution were measured while changing the angle of incidence. The mf-BRDF model combined with the Lambert model with scattering probability $p_{L} = 0.039\pm0.003$ reproduced the experimental results well. We have thus established a procedure to evaluate the characteristics of UCN guide tubes with a surface roughness of approximately 10 nm.

physics.ins-det

Angular distribution of $\gamma$-rays from a neutron-induced $p$-wave resonance of $^{132}$Xe

A neutron-energy dependent angular distribution was measured for individual $\gamma$-rays from the 3.2 eV $p$-wave resonance of $^{131}$Xe+$n$, that shows enhanced parity violation owing to a mixing between $s$- and $p$-wave amplitudes. The $\gamma$-ray transitions from the $p$-wave resonance were identified, and the angular distribution with respect to the neutron momentum was evaluated as a function of the neutron energy for 7132 keV $\gamma$-rays, which correspond to a transition to the 1807 keV excited state of $^{132}$Xe. The angular distribution is considered to originate from the interference between $s$- and $p$-wave amplitudes, and will provide a basis for a quantitative understanding of the enhancement mechanism of the fundamental parity violation in compound nuclei.

nucl-ex

Measurement of the transverse asymmetry of $\gamma$-rays in the $^{117}$Sn(n,$\gamma$)$^{118}$Sn reaction

Largely enhanced parity-violating effects observed in compound resonances induced by epithermal neutrons are currently attributed to the mixing of parity-unfavored partial amplitudes in the entrance channel of the compound states. Furthermore, it is proposed that the same mechanism that enhances the parity-violation also enhances the breaking of time-reversal-invariance in the compound nucleus. The entrance-channel mixing induces energy-dependent spin-angular correlations of individual $\gamma$-rays emitted from the compound nuclear state. For a detailed study of the mixing model, a $\gamma$-ray yield in the reaction of $^{117}$Sn(n,$\gamma$)$^{118}$Sn was measured using the pulsed beam of polarized epithermal neutrons and Ge detectors. An angular dependence of asymmetric $\gamma$-ray yields for the orientation of the neutron polarization was observed.

nucl-ex

Characterization of electroless nickel-phosphorus plating for ultracold-neutron storage

Electroless nickel plating is an established industrial process that provides a robust and relatively low-cost coating suitable for transporting and storing ultracold neutrons (UCN). Using roughness measurements and UCN-storage experiments we characterized UCN guides made from polished aluminum or stainless-steel tubes plated by several vendors. All electroless nickel platings were similarly suited for UCN storage with an average loss probability per wall bounce of $2.8\cdot10^{-4}$ to $4.1\cdot10^{-4}$ for energies between 90 neV and 190 neV, or a ratio of imaginary to real Fermi potential $\eta$ of $1.7\cdot10^{-4}$ to $3.3\cdot10^{-4}$. Measurements at different elevations indicate that the energy dependence of UCN losses is well described by the imaginary Fermi potential. Some special considerations are required to avoid an increase in surface roughness during the plating process and hence a reduction in UCN transmission. Increased roughness had only a minor impact on storage properties. Based on these findings we chose a vendor to plate the UCN-production vessel that will contain the superfluid-helium converter for the new TRIUMF UltraCold Advanced Neutron (TUCAN) source, achieving acceptable UCN-storage properties with ${\eta=3.5(5)\cdot10^{-4}}$.

nucl-ex