arXiv ScienceSearch

arXiv subjects

M. Goryachev

Publications and source records attributed to M. Goryachev.

At least 19 recordsLinked to original sources

Dynamically tuneable helicity in twisted electromagnetic resonators

We report the generation of helical electromagnetic radiation in a microwave cavity resonator, achieved by introducing mirror asymmetry, i.e., chirality, through a controlled geometric twist of the conducting boundary conditions. The emergence of electromagnetic helicity is attributed to a nonzero spatial overlap between the electric and magnetic mode eigenvectors, quantified by $\text{Im}\left[\vec{\mathbf{E}}_i(\vec{r})\cdot{\vec{\mathbf{H}}}_i^*(\vec{r})\right]$, a feature not observed in conventional cavity resonators. This phenomenon originates from magnetoelectric coupling between nearly degenerate transverse electric (TE) and transverse magnetic (TM) modes, resulting in a measurable frequency shift of the resonant modes as a function of the twist angle, $\phi$. In addition to the bulk helicity induced by global geometric twist, internal helical corrugations break structural symmetry on the surface, introducing an effective surface chirality $\kappa_{\text{eff}}$, which perturbs the resonant conditions and contributes to asymmetric frequency tuning. By dynamically varying $\phi$, we demonstrate real-time, macroscopic manipulation of both electromagnetic helicity and resonant frequency. Furthermore, we investigate the underlying mode-coupling dynamics of the system, highlighting strong photon-photon interactions.

physics.optics

Distinct Berry Phases in a Single Triangular M\"{o}bius Microwave Resonator

We report the experimental observation of two distinct Berry phases ($+\frac{2\pi}{3}$ and $-\frac{2\pi}{3}$) generated on the surface of a M\"{o}bius cavity resonator at microwave frequencies supporting the TE$_{1,0,n}$ mode family. This resonator consists of a twisted, mirror-asymmetric prism with a cross-section of the triangular $D_3$ symmetry group, bent around on itself to form a ring. This geometric class supports resonant modes with nonzero electromagnetic helicity (i.e. nonzero $\vec{E}\cdot\vec{B}$ product) at microwave frequencies. There exist modes with three-fold rotational symmetry as well as those that exhibit no rotational symmetry. The latter result in an accumulated Berry phase whilst the former do not, which is determined from the measured frequency shift of the modes when compared to a mirror-symmetric resonator of otherwise equivalent geometry.

physics.class-ph

Search for Axion Dark Matter from 1.1 to 1.3 GHz with ADMX

Axion dark matter can satisfy the conditions needed to account for all of the dark matter and solve the strong CP problem. The Axion Dark Matter eXperiment (ADMX) is a direct dark matter search using a haloscope to convert axions to photons in an external magnetic field. Key to this conversion is the use of a microwave resonator that enhances the sensitivity at the frequency of interest. The ADMX experiment boosts its sensitivity using a dilution refrigerator and near quantum-limited amplifier to reduce the noise level in the experimental apparatus. In the most recent run, ADMX searched for axions between 1.10-1.31 GHz to extended Kim-Shifman-Vainshtein-Zakharov (KSVZ) sensitivity. This Letter reports on the results of that run, as well as unique aspects of this experimental setup.

hep-ex

Electromagnetic Helicity in Twisted Cavity Resonators

Through left- or right-handed twisting, we investigate the impact of mirror-asymmetry (chirality) of the conducting boundary conditions of an equilaterial triangular cross-section electromagnetic resonator. We observe the generation of eigenmodes with non-zero electromagnetic helicity as a result of the coupling of near degenerate TE$_{11(p+1)}$ and TM$_{11p}$ modes. This can be interpreted as an emergence of magneto-electric coupling, which in turn produces a measurable shift in resonant mode frequency as a function of twist angle. We show that this coupling mechanism is equivalent to introducing a non-zero chirality material parameter $\kappa_\text{eff}$ or axion field $\theta_{\text{eff}}$ to the medium. Our findings demonstrate the potential for real-time, macroscopic manipulation of electromagnetic helicity.

physics.class-ph

Improved Receiver Noise Calibration for ADMX Axion Search: 4.54 to 5.41 $\mu$eV

Axions are a well-motivated candidate for dark matter. The preeminent method to search for axion dark matter is known as the axion haloscope, which makes use of the conversion of axions to photons in a large magnetic field. Due to the weak coupling of axions to photons however, the expected signal strength is exceptionally small. To increase signal strength, many haloscopes make use of resonant enhancement and high gain amplifiers, while also taking measures to keep receiver noise as low as possible such as the use of dilution refrigerators and ultra low-noise electronics. In this paper we derive the theoretical noise model based on the sources of noise found within a typical axion haloscope receiver chain, using the Axion Dark Matter eXperiment (ADMX) as a case study. We present examples of different noise calibration measurements at 1280~MHz taken during ADMX's most recent data-taking run. These new results shed light on a previously unidentified interaction between the cavity and JPA, as well as provide a better understanding of the systematic uncertainty on the system noise temperature used in the axion search analysis for this data-taking run. Finally, the consistency between the measurements and the detailed model provide suggestions for future improvements within ADMX and other axion haloscopes to reach a lower noise temperature.

hep-ex

Upconversion of Phonon Modes into Microwave Photons in a Lithium Niobate Bulk Acoustic Wave Resonator Coupled to a Microwave Cavity

The coupling between acoustic vibrations in a lithium niobate bulk acoustic wave resonator and microwave photons of a re-entrant microwave cavity was investigated at a temperature close to 4 K. Coupling was achieved by placing the acoustic resonator in the location of the re-entrant cavity electric field maxima, in a symmetric "split-post" configuration, with a large overlap between the microwave field and the acoustic mode, allowing acoustic modulations of the microwave frequency. We show that the acoustic modes in this setup retain large inherent quality factors of greater than $10^6$. A maximum optomechanical coupling rate was determined to be $g_0$ = 0.014 mHz, four orders of magnitude larger than previous results obtained using a quartz BAW at 4 K in a similar experimental setup, but using a single post-re-entrant cavity resonator.

quant-ph

Search for non-virialized axions with 3.3-4.2 $\mu$eV mass at selected resolving powers

The Axion Dark Matter eXperiment is sensitive to narrow axion flows, given axions compose a fraction of the dark matter with a non-negligible local density. Detecting these low-velocity dispersion flows requires a high spectral resolution and careful attention to the expected signal modulation due to Earth's motion. We report an exclusion on the local axion dark matter density in narrow flows of $\rho_a \gtrsim 0.03\,\mathrm{GeV/cm^3}$ and $\rho_a \gtrsim 0.004\,\mathrm{GeV/cm^3}$ for Dine-Fischler-Srednicki-Zhitnitski and Kim-Shifman-Vainshtein-Zakharov axion-photon couplings, respectively, over the mass range $3.3-4.2\,\mu\text{eV}$. Measurements were made at selected resolving powers to allow for a range of possible velocity dispersions.

astro-ph.CO

Axion Dark Matter eXperiment around 3.3 {\mu}eV with Dine-Fischler-Srednicki-Zhitnitsky Discovery Ability

We report the results of a QCD axion dark matter search with discovery ability for Dine Fischler Srednicki Zhitnitsky (DFSZ) axions using an axion haloscope. Sub-Kelvin noise temperatures are reached with an ultra low-noise Josephson parametric amplifier cooled by a dilution refrigerator. This work excludes (with a 90% confidence level) DFSZ axions with masses between 3.27 to 3.34 $\mu$eV, assuming a standard halo model with a local energy density of 0.45 GeV/cm$^3$ made up 100% of axions.

hep-ex

Non-Virialized Axion Search Sensitive to Doppler Effects in the Milky Way Halo

The Axion Dark Matter eXperiment (ADMX) has previously excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions between 680-790 MHz under the assumption that the dark matter is described by the isothermal halo model. However, the precise nature of the velocity distribution of dark matter is still unknown, and alternative models have been proposed. We report the results of a non-virialized axion search over the mass range 2.81-3.31 {\mu}eV, corresponding to the frequency range 680-800 MHz. This analysis marks the most sensitive search for non-virialized axions sensitive to Doppler effects in the Milky Way Halo to date. Accounting for frequency shifts due to the detector's motion through the Galaxy, we exclude cold flow relic axions with a velocity dispersion of order 10^-7 c with 95% confidence.

astro-ph.CO

Search for a dark-matter induced Cosmic Axion Background with ADMX

We report the first result of a direct search for a Cosmic ${\it axion}$ Background (C$a$B) - a relativistic background of axions that is not dark matter - performed with the axion haloscope, the Axion Dark Matter eXperiment (ADMX). Conventional haloscope analyses search for a signal with a narrow bandwidth, as predicted for dark matter, whereas the C$a$B will be broad. We introduce a novel analysis strategy, which searches for a C$a$B induced daily modulation in the power measured by the haloscope. Using this, we repurpose data collected to search for dark matter to set a limit on the axion photon coupling of a C$a$B originating from dark matter cascade decay via a mediator in the 800-995 MHz frequency range. We find that the present sensitivity is limited by fluctuations in the cavity readout as the instrument scans across dark matter masses. Nevertheless, we suggest that these challenges can be surmounted using superconducting qubits as single photon counters, and allow ADMX to operate as a telescope searching for axions emerging from the decay of dark matter. The daily modulation analysis technique we introduce can be deployed for various broadband RF signals, such as other forms of a C$a$B or even high-frequency gravitational waves.

hep-ex

Low Frequency (100-600 MHz) Searches with Axion Cavity Haloscopes

We investigate reentrant and dielectric loaded cavities for the purpose of extending the range of axion cavity haloscopes to lower masses, below the range where the Axion Dark Matter eXperiment (ADMX) has already searched. Reentrant and dielectric loaded cavities were simulated numerically to calculate and optimize their form factors and quality factors. A prototype reentrant cavity was built and its measured properties were compared with the simulations. We estimate the sensitivity of axion dark matter searches using reentrant and dielectric loaded cavities inserted in the existing ADMX magnet at the University of Washington and a large magnet being installed at Fermilab.

hep-ph

Searching for Ultra-Light Axions with Twisted Cavity Resonators of Anyon Rotational Symmetry with Bulk Modes of Non-Zero Helicity

M\"obius-ring resonators stem from a well-studied and fascinating geometrical structure that features a one-sided topology; the M\"obius strip, and have been shown to exhibit fermion rotational symmetry with respect to a ring resonator with no twist (which exhibits boson rotational symmetry) (see PhysRevLett.101.247701). Here, we present a new type of resonator through the formation of twisted hollow structures using equilateral triangular cross-sections, which leads to the realization of a cavity with anyon rotational symmetry. Unlike all previous cavity resonators, the anyon resonator permits the existence of bulk resonant modes that exhibit non-zero electromagnetic helicity in vacuo, with a non-zero overlap of the electric and magnetic mode eigenvectors, $\int \mathbf{E}_p\cdot\mathbf{B}_p~d\tau$, integrated over the cavity volume. In the upconversion limit, we show that these non-zero helical modes couple naturally to ultra-light dark matter axions within the bandwidth of the resonator by adding amplitude-modulated sidebands through the axion-photon chiral anomaly. Thus, we show a sensitive ultra-light dark matter experiment may be realized by implementing such a resonator in an ultra-stable oscillator configuration and searching for signals in the Fourier spectrum of amplitude fluctuations. This removes the typical requirement for an external magnetic field and therefore permits the use of superconducting materials to reduce surface losses and enhance sensitivity to axions.

hep-ph

Dark Matter Axion Search Using a Josephson Traveling Wave Parametric Amplifier

We present a new exclusion bound of axion-like particle dark matter with axion-photon couplings above $\mathrm{10^{-13}}$ $\mathrm{GeV^{-1}}$ over the frequency range 4796.7--4799.5 MHz, corresponding to a narrow range of axion masses centered around 19.84 $\mu$eV. This measurement represents the first implementation of a Josephson Traveling Wave Parametric Amplifier (JTWPA) in a dark matter search. The JTWPA was operated in the insert of the Axion Dark Matter eXperiment (ADMX) as part of an independent receiver chain that was attached to a 0.588-liter cavity. The ability of the JTWPA to deliver high gain over a wide (3 GHz) bandwidth has engendered interest from those aiming to perform broadband axion searches, a longstanding goal in this field.

hep-ex

Search for "Invisible" Axion Dark Matter in the $3.3\text{-}4.2~{\mu}$eV Mass Range

We report the results from a haloscope search for axion dark matter in the $3.3\text{-}4.2~{\mu}$eV mass range. This search excludes the axion-photon coupling predicted by one of the benchmark models of "invisible" axion dark matter, the KSVZ model. This sensitivity is achieved using a large-volume cavity, a superconducting magnet, an ultra low noise Josephson parametric amplifier, and sub-Kelvin temperatures. The validity of our detection procedure is ensured by injecting and detecting blind synthetic axion signals.

hep-ex

Challenges and Opportunities of Gravitational Wave Searches at MHz to GHz Frequencies

The first direct measurement of gravitational waves by the LIGO and Virgo collaborations has opened up new avenues to explore our Universe. This white paper outlines the challenges and gains expected in gravitational wave searches at frequencies above the LIGO/Virgo band, with a particular focus on Ultra High-Frequency Gravitational Waves (UHF-GWs), covering the MHz to GHz range. The absence of known astrophysical sources in this frequency range provides a unique opportunity to discover physics beyond the Standard Model operating both in the early and late Universe, and we highlight some of the most promising gravitational sources. We review several detector concepts which have been proposed to take up this challenge, and compare their expected sensitivity with the signal strength predicted in various models. This report is the summary of the workshop "Challenges and opportunities of high-frequency gravitational wave detection" held at ICTP Trieste, Italy in October 2019, that set up the stage for the recently launched Ultra-High-Frequency Gravitational Wave (UHF-GW) initiative.

gr-qc

Axion Dark Matter eXperiment: Run 1B Analysis Details

Searching for axion dark matter, the ADMX collaboration acquired data from January to October 2018, over the mass range 2.81--3.31 $μ$eV, corresponding to the frequency range 680--790 MHz. Using an axion haloscope consisting of a microwave cavity in a strong magnetic field, the ADMX experiment excluded Dine-Fischler-Srednicki-Zhitnisky (DFSZ) axions at 100% dark matter density over this entire frequency range, except for a few gaps due to mode crossings. This paper explains the full ADMX analysis for Run 1B, motivating analysis choices informed by details specific to this run.

astro-ph.CO

Testing of Generalized Uncertainty Principle With Macroscopic Mechanical Oscillators and Pendulums

Recent progress in observing and manipulating mechanical oscillators at quantum regime provides new opportunities of studying fundamental physics, for example, to search for low energy signatures of quantum gravity. For example, it was recently proposed that such devices can be used to test quantum gravity effects, by detecting the change in the [x,p] commutation relation that could result from quantum gravity corrections. We show that such a correction results in a dependence of a resonant frequency of a mechanical oscillator on its amplitude, which is known as amplitude-frequency effect. By implementing this new method we measure amplitude-frequency effect for 0.3 kg ultra high-Q sapphire split-bar mechanical resonator and for 10 mg quartz bulk acoustic wave resonator. Our experiments with sapphire resonator have established the upper limit on quantum gravity correction constant for $β_0<5 \times10^6$ which is a factor of 6 better than previously detected. The reasonable estimates of $β_0$ from experiments with quartz resonators yield an even more stringent limit of $4\times10^4$. The data sets of 1936 measurement of physical pendulum period by Atkinson results in significantly stronger limitations on $β_0 \ll 1$. Yet, due to the lack of proper pendulum frequency stability measurement in these experiments, the exact upper bound on $β_0$ can not be reliably established. Moreover, pendulum based systems only allow testing a specific form of the modified commutator that depends on the mean value of momentum. The electro-mechanical oscillators to the contrary enable testing of any form of generalized uncertainty principle directly due to much higher stability and a higher degree of control.

quant-ph

Piezo-optomechanical coupling of a 3D microwave resonator to a bulk acoustic wave crystalline resonator

We report the observation of coupling between a 3D microwave cavity mode and a bulk mechanical resonator mediated by piezoelectric and radiation pressure effects. The system is composed of a quartz bulk acoustic wave resonator placed inside a microwave re-entrant cavity, which is designed to act as both the electrodes for piezoelectric actuation as well as a 3D resonator. The cavity electromagnetic mode is modulated by a 5 MHz bulk acoustic wave shear mode, which is modeled and experimentally verified using the input-output formalism. Through finite element method simulations, we calculate the various contributions to the electromechanical coupling and discuss the potential of the system to reach high cooperativities as well as suitable applications.

physics.app-ph