arXiv Science⌕ Search

arXiv subjects

M. Febbraro

Publications and source records attributed to M. Febbraro.

At least 19 recordsLinked to original sources

Graphene Transfer for Vertical Amorphous-Selenium Photodetectors: Fabrication, Optical Transmission and Operation at 77 K

Graphene can serve as a VUV transparent electrode in vertical photodetector devices. Using an optically transparent graphene as a top-electrode of amorphous selenium (a-Se) photoconductor requires transfer process compatible with the thermal and chemical sensitivities of a-Se thin films. The baking and polymer-removal steps of conventional commercial Trivial Transfer graphene procedures are undesirable because heating can promote selenium crystallization and prolonged solvent exposure can cause delamination. We implement two alternatives: PMMA-free transfer of nominal 50-layer graphene and transfer of nominal 10-layer graphene using an approximately 80 nm PMMA support removed in acetone at 40C. Raman G and 2D bands identify graphene after transfer. Separate graphene/MgF2 specimens are characterized by dark-corrected transmission measurements over 120-325 nm and compared with earlier single-layer and nominal 6-8-layer Trivial Transfer spectra. The completed graphene/a-Se/Cr devices produce bias-dependent voltage transients under pulsed 415 nm illumination at 293 K and 77 K. These results establish an a-Se-compatible fabrication route for graphene-electrode devices and demonstrate vertical device operation at both room and cryogenic temperatures. The completed devices provide a platform for detection-efficiency studies, and direct VUV photoresponse measurements now underway.

physics.ins-det↗

Energy Calibration and Performance of HPGe Detectors in the LEGEND-200 Experiment

This paper describes the energy scale procedures and germanium detectors performance in the LEGEND-200 experiment, a critical component for the first unblinding in the search for neutrinoless double beta decay. We detail the digital signal processing pipeline, the methodologies for peak-shape modeling and energy calibration procedures utilizing weekly $^{228}$Th source calibration runs. The optimized energy reconstruction achieves a combined average resolution of $(2.47 \pm 0.08)$~keV at $Q_{ββ} = 2039$~keV. The weekly variation of calibration peak positions are below 0.05~keV for energies up to 2614.5~keV, showing a high stability of the energy scale over time and across detectors. Furthermore, systematic corrections effectively address residual non-linearities and energy bias in the region of interest.

physics.ins-det↗

Characterization of Lateral Amorphous Selenium Photodetectors for Low-Photon and VUV Detection at Cryogenic Temperatures

The performance of amorphous selenium (a-Se) as a cryogenic photodetector material is evaluated through a series of experiments using laterally structured devices operated in a custom optical test stand. These studies investigate the response of a-Se detectors to low-photon fluxes at high electric fields near avalanche conditions, the linearity of the photoconductive response over a wide dynamic range and the direct detection of narrowband 130 nm vacuum ultraviolet (VUV) illumination. At 87 K, matched-filter analysis shows reliable single-shot detection with efficiencies greater than or equal to 80 percent and area under the curve (AUC) greater than or equal to 0.85 using as few as approximately 6800 incident 401 nm photons, corresponding to approximately 3400 photons within field-active regions after accounting for geometric constraints. Measurements are performed at cryogenic temperatures using calibrated photon fluxes derived from a silicon photomultiplier reference and a characterized optical filter stack. Additional experiments using a tellurium-doped a-Se (a-SeTe) device explore the material's behavior under identical test conditions and demonstrate that avalanche is achievable in a-SeTe at cryogenic temperatures. The results demonstrate reproducible low-noise operation, VUV sensitivity and field-dependent gain behavior in a lateral a-Se architecture, representing the first reported observation of avalanche multiplication in laterally structured a-Se and a-SeTe devices at cryogenic temperatures. These findings support the potential integration of laterally structured a-Se devices into next-generation pixelated liquid-argon time projection chambers (TPCs) requiring scalable, high-field-compatible photon detection systems.

physics.ins-det↗

Strength measurement of the $E_α^{lab}$ = 830 keV resonance in $^{22}\rm{Ne}(α,n)^{25}\rm{Mg}$ reaction using a stilbene detector

The interplay between the $^{22}$Ne$(α,γ)^{26}$Mg and the competing $^{22}$Ne$(α,n)^{25}$Mg reactions determines the efficiency of the latter as a neutron source at the temperatures of stellar helium burning. In both cases, the rates are dominated by the $α$-cluster resonance at 830 keV. This resonance plays a particularly important role in determining the strength of the neutron flux for both the weak and main $s$-process as well as the $n$-process. Recent experimental studies based on transfer reactions suggest that the neutron and $γ$-ray strengths for this resonance are approximately equal. In this study, the $^{22}$Ne$(α,n)^{25}$Mg resonance strength has been remeasured and found to be similar to the previous direct studies. This reinforces an 830 keV resonance strength that is approximately a factor of three larger for the $^{22}$Ne$(α,n)^{25}$Mg reaction than for the $^{22}$Ne$(α,γ)^{26}$Mg reaction.

nucl-ex↗

Measurement of the Electron-Neutrino Charged-Current Cross Sections on ${}^{127}$I with the COHERENT NaI$ν$E detector

Using an 185-kg NaI[Tl] array, COHERENT has measured the inclusive electron-neutrino charged-current cross section on ${}^{127}$I with pion decay-at-rest neutrinos produced by the Spallation Neutron Source at Oak Ridge National Laboratory. Iodine is one the heaviest targets for which low-energy ($\leq$ 50 MeV) inelastic neutrino-nucleus processes have been measured, and this is the first measurement of its inclusive cross section. After a five-year detector exposure, COHERENT reports a flux-averaged cross section for electron neutrinos of $9.2^{+2.1}_{-1.8} \times 10^{-40}$ cm$^2$. This corresponds to a value that is $\sim$41% lower than predicted using the MARLEY event generator with a measured Gamow-Teller strength distribution. In addition, the observed visible spectrum from charged-current scattering on $^{127}$I has been measured between 10 and 55 MeV, and the exclusive zero-neutron and one-or-more-neutron emission cross sections are measured to be $5.2^{+3.4}_{-3.1} \times 10^{-40}$ and $2.2^{+3.5}_{-2.2} \times 10^{-40}$ cm$^2$, respectively.

nucl-ex↗

Accessing new physics with an undoped, cryogenic CsI CEvNS detector for COHERENT at the SNS

We consider the potential for a 10-kg undoped cryogenic CsI detector operating at the Spallation Neutron Source to measure coherent elastic neutrino-nucleus scattering and its sensitivity to discover new physics beyond the standard model. Through a combination of increased event rate, lower threshold, and good timing resolution, such a detector would significantly improve on past measurements. We considered tests of several beyond-the-standard-model scenarios such as neutrino non-standard interactions and accelerator-produced dark matter. This detector's performance was also studied for relevant questions in nuclear physics and neutrino astronomy, namely the weak charge distribution of CsI nuclei and detection of neutrinos from a core-collapse supernova.

hep-ex↗

Measurement of ${}^{nat}$Pb($ν_e$,X$n$) production with a stopped-pion neutrino source

Using neutrinos produced at the Spallation Neutron Source (SNS) at Oak Ridge National Laboratory (ORNL), the COHERENT collaboration has studied the Pb($ν_e$,X$n$) process with a lead neutrino-induced-neutron (NIN) detector. Data from this detector are fit jointly with previously collected COHERENT data on this process. A combined analysis of the two datasets yields a cross section that is $0.29^{+0.17}_{-0.16}$ times that predicted by the MARLEY event generator using experimentally-measured Gamow-Teller strength distributions, consistent with no NIN events at 1.8$σ$. This is the first inelastic neutrino-nucleus process COHERENT has studied, among several planned exploiting the high flux of low-energy neutrinos produced at the SNS.

hep-ex↗

COHERENT Collaboration data release from the measurements of CsI[Na] response to nuclear recoils

Description of the data release 10.13139/OLCF/1969085 (https://doi.ccs.ornl.gov/ui/doi/426) from the measurements of the CsI[Na] response to low energy nuclear recoils by the COHERENT collaboration. The release corresponds to the results published in "D. Akimov et al 2022 JINST 17 P10034". We share the data in the form of raw ADC waveforms, provide benchmark values, and share plots to enhance the transparency and reproducibility of our results. This document describes the contents of the data release as well as guidance on the use of the data.

physics.ins-det↗

First direct measurement constraining the $^{34}$Ar($α$,p)$^{37}$K reaction cross section for mixed hydrogen and helium burning in accreting neutron stars

The rate of the final step in the astrophysical $α$p-process, the $^{34}$Ar($α$,\textit{p})$^{37}$K reaction, suffers from large uncertainties due to lack of experimental data, despite having a considerable impact on the observable light curves of x-ray bursts and the composition of the ashes of hydrogen and helium burning on accreting neutron stars. We present the first direct measurement constraining the $^{34}$Ar($α$,p)$^{37}$K reaction cross section, using the Jet Experiments in Nuclear Structure and Astrophysics (JENSA) gas jet target. The combined cross section for the $^{34}$Ar,Cl($α$,p)$^{37}$K,Ar reaction is found to agree well with Hauser-Feshbach predictions. The $^{34}$Ar($α$,2p)$^{36}$Ar cross section, which can be exclusively attributed to the $^{34}$Ar beam component, also agrees to within the typical uncertainties quoted for statistical models. This indicates the applicability of the statistical model for predicting astrophysical ($α$,p) reaction rates in this part of the $α$p process, in contrast to earlier findings from indirect reaction studies indicating orders-of-magnitude discrepancies. This removes a significant uncertainty in models of hydrogen and helium burning on accreting neutron stars.

nucl-ex↗

First Probe of Sub-GeV Dark Matter Beyond the Cosmological Expectation with the COHERENT CsI Detector at the SNS

The COHERENT collaboration searched for scalar dark matter particles produced at the Spallation Neutron Source with masses between 1 and 220~MeV/c$^2$ using a CsI[Na] scintillation detector sensitive to nuclear recoils above 9~keV$_\text{nr}$. No evidence for dark matter is found and we thus place limits on allowed parameter space. With this low-threshold detector, we are sensitive to coherent elastic scattering between dark matter and nuclei. The cross section for this process is orders of magnitude higher than for other processes historically used for accelerator-based direct-detection searches so that our small, 14.6~kg detector significantly improves on past constraints. At peak sensitivity, we reject the flux consistent with the cosmologically observed dark-matter concentration for all coupling constants $α_D<0.64$, assuming a scalar dark-matter particle. We also calculate the sensitivity of future COHERENT detectors to dark-matter signals which will ambitiously test multiple dark-matter spin scenarios.

hep-ex↗

Neutrinoless Double Beta Decay

This White Paper, prepared for the Fundamental Symmetries, Neutrons, and Neutrinos Town Meeting related to the 2023 Nuclear Physics Long Range Plan, makes the case for double beta decay as a critical component of the future nuclear physics program. The major experimental collaborations and many theorists have endorsed this white paper.

nucl-ex↗

Production and validation of scintillating structural components from low-background Poly(ethylene naphthalate)

Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of background events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.

physics.ins-det↗

Measurement of scintillation response of CsI[Na] to low-energy nuclear recoils by COHERENT

We present results of several measurements of CsI[Na] scintillation response to 3-60 keV energy nuclear recoils performed by the COHERENT collaboration using tagged neutron elastic scattering experiments and an endpoint technique. Earlier results, used to estimate the coherent elastic neutrino-nucleus scattering (CEvNS) event rate for the first observation of this process achieved by COHERENT at the Spallation Neutron Source (SNS), have been reassessed. We discuss corrections for the identified systematic effects and update the respective uncertainty values. The impact of updated results on future precision tests of CEvNS is estimated. We scrutinize potential systematic effects that could affect each measurement. In particular we confirm the response of the H11934-200 Hamamatsu photomultiplier tube (PMT) used for the measurements presented in this study to be linear in the relevant signal scale region.

physics.ins-det↗

Physics Opportunities in the ORNL Spallation Neutron Source Second Target Station Era

The Oak Ridge National Laboratory (ORNL) Spallation Neutron Source (SNS) First Target Station (FTS), used by the COHERENT experiment, provides an intense and extremely high-quality source of pulsed stopped-pion neutrinos, with energies up to about 50 MeV. Upgrades to the SNS are planned, including a Second Target Station (STS), which will approximately double the expected neutrino flux while maintaining quality similar to the FTS source. Furthermore, additional space for ten-tonne scale detectors may be available. We describe here exciting opportunities for neutrino physics, other particle and nuclear physics, and detector development using the FTS and STS neutrino sources.

hep-ex↗

Optical properties of low background PEN structural components for the LEGEND-200 experiment

Polyethylene Naphthalate (PEN) plastic scintillator has been identified as potential self-vetoing structural material in low-background physics experiments. Scintillating components have been produced radio-pure from PEN using injection compression molding technology. These low-background PEN components will be used as active holders to mount the Germanium detectors in the \legend-$200$ neutrinoless double beta decay experiment. In this paper we present the measurement of the optical properties of these PEN components. Thus, the emission spectrum, time constant, attenuation and bulk absorption length as well as light output and light yield are reported. In addition, the surface of these PEN components has been characterized and an estimation of the surface roughness is presented. Moreover, the light output of the final \legend-$200$ detector holders has been measured and is reported. These measurements were used to estimate the self-vetoing efficiency of these holders.

physics.ins-det↗

Enhanced low-energy supernova burst detection in large liquid argon time projection chambers enabled by Q-Pix

The detection of neutrinos from core-collapse supernovae may reveal important process features as well as neutrino properties. The detection of supernova neutrinos is one of the main science drivers for future kiloton-scale neutrino detectors based on liquid argon. Here we show that for such detectors the intrinsically 3D readout in Q-Pix offers numerous advantages relative to a wire-based readout, such as higher reconstruction efficiency, lower energy threshold, considerably lower data rates, and potential pointing information.

hep-ex↗

CLARION2-TRINITY: a Compton-suppressed HPGe and GAGG:Ce-Si-Si array for absolute cross-section measurements with heavy ions

The design and performance of a new Compton-suppressed HPGe and charged-particle array, CLARION2-TRINITY, are described. The TRINITY charged-particle array is comprised of 64 Cerium-doped Gadolinium Aluminium Gallium Garnet (GAGG:Ce) crystals configured into five rings spanning 7-54 degrees, and two annular silicon detectors that can shadow or extend the angular coverage to backward angles with minimal $γ$-ray attenuation. GAGG:Ce is a non-hygroscopic, bright, and relatively fast scintillator with a light distribution well matched to SiPMs. Count rates up to 40 kHz per crystal are sustainable. Fundamental characteristics of GAGG:Ce are measured and presented, including light- and heavy-ion particle identification (PID) capability, pulse-height defects, radiation hardness, and emission spectra. The CLARION2 array consists of up to 16 Compton-suppressed HPGe Clover detectors ($\approx4\%$ efficiency at 1 MeV) configured into four rings (eight HPGe crystal rings) using a non-Archimedean geometry that suppresses back-to-back coincident 511-keV gamma rays. The entire array is instrumented with 100- and 500-MHz (14 bit) waveform digitizers which enable triggerless operation, pulse-shape discrimination, fast timing, and pileup correction. Finally, two examples of experimental data taken during the commissioning of the CLARION2-TRINITY system are given: a PID spectrum from $^{16}$O + $^{18}$O fusion-evaporation, and PID and Doppler-corrected $γ$-ray spectra from $^{48}$Ti + $^{12}$C Coulomb excitation.

physics.ins-det↗

Development of a novel, windowless, amorphous selenium based photodetector for use in liquid noble detectors

Detection of the vacuum ultraviolet (VUV) scintillation light produced by liquid noble elements is a central challenge in order to fully exploit the available timing, topological, and calorimetric information in detectors leveraging these media. In this paper, we characterize a novel, windowless amorphous selenium based photodetector with direct sensitivity to VUV light. We present here the manufacturing and experimental setup used to operate this detector at low transport electric fields (2.7-5.2 V/$μ$m) and across a wide range of temperatures (77K-290K). This work shows that the first proof-of-principle device windowless amorphous selenium is robust under cryogenic conditions, responsive to VUV light at cryogenic temperatures, and preserves argon purity. These findings motivate a continued exploration of amorphous selenium devices for simultaneous detection of scintillation light and ionization charge in noble element detectors.

physics.ins-det↗