arXiv Science⌕ Search

arXiv subjects

M. Cavallina

Publications and source records attributed to M. Cavallina.

2 recordsLinked to original sources

Evidence for MeV Radiation from a Large-Amplitude Crystalline Undulator

We report evidence for MeV radiation from a large-amplitude crystalline undulator in which 35 GeV/c positrons channel along periodically bent Si(110) planes. Si$_3$N$_4$ stressors produce ten periods with $λ_u = 334~μ$m and midplane amplitude $A_u \simeq 1.85$ nm (XRD-validated modeling). Under planar alignment, the energy-loss spectrum shows an excess over the misaligned case peaking at $6.8 \pm 0.3$ MeV ($4.05σ$), in agreement with simulations and the 7.2 MeV analytical estimate. Simulations for 20 GeV FCC-ee injector positrons predict a peak brilliance of $1.8\times10^{21}$ photons/(s mm$^2$ mrad$^2$ 0.1% BW).

physics.acc-ph↗

Design and beam-test characterization of the CRILIN semi-homogeneous crystal calorimeter

CRILIN is a high-granularity semi-homogeneous electromagnetic calorimeter based on longitudinally segmented PbF$_2$ crystal matrices read out by UV-extended silicon photomultipliers. The concept combines fast Cherenkov response, fine transverse granularity, longitudinal shower information, and radiation tolerance for future lepton-collider experiments. This paper reports the construction of a large-area prototype and its performance measured in beam tests at the CERN SPS. The detector comprises five $7\times7$ PbF$_2$ crystal matrices, has a depth of about $22X_0$, and is read out by four $3\times3~\mathrm{mm}^2$ SiPMs per crystal integrated in a single electronic channel. Electron data between 10 and 120~GeV and dedicated 150~GeV muon data were used to characterize the detector response. A time resolution below 50~ps is achieved for electron energies above 10~GeV, reaching values below 20~ps above 60~GeV. The energy resolution is described by a stochastic term of $(6.58\pm0.04)\%/\sqrt{E/\mathrm{GeV}}$ and a constant term of $(0.23\pm0.02)\%$, with an additional noise contribution fixed from pedestal data. The longitudinal segmentation enables event-by-event corrections based on the reconstructed shower development, resulting in a significant improvement of the energy resolution. A light yield of approximately 0.54~photoelectrons/MeV is measured consistently using both electron showers and minimum-ionizing particles. A Geant4-based simulation incorporating the relevant experimental effects reproduces the measured energy resolution. These results validate the CRILIN architecture as a compact, fast, and longitudinally segmented electromagnetic calorimeter for future collider experiments.

physics.ins-det↗