Fast Timing and TCT Measurement Results of CNM Double-Sided 3D Sensors

Sensors with fast timing capabilities (on the order of tens of picoseconds) are a critical component of future HEP tracking detectors, providing the ability to disentangle high multiplicity events. Silicon 3D sensors are capable of delivering this temporal resolution and additionally display an excellent radiation hardness, suitable for the harsh environments expected in future hadron colliders (e.g. FCC-hh). In the course of the RD50 project "3D detectors optimized for timing applications", double-sided 3D sensors with two different column layouts, hexagonal and orthogonal, and different column counts were designed and produced by CNM. In this study, results of IV, top-TCT and source timing measurements of unirradiated as well as proton irradiated sensor structures are presented. The IV characterisation shows a strong decrease of the overall high leakage current of the sensors after irradiation. Top-TCT measurements with both an infrared and red laser reveal a mostly homogenous charge collection in the sensor bulk, while higher signals are observed in the outermost columns for surface charge injection. The time resolution of sensors irradiated up to a $1 \, \mathrm{MeV}$ neutron equivalent fluence of $3\times10^{15} \, \mathrm{cm^{-2}}$ reaches down to ca. $65\,\mathrm{ps}$, showing only a slight degradation compared to unirradiated sensors.

physics.ins-det

Novel Strip-like Readout Geometries in Resistive AC-coupled Silicon Detectors (RSD / AC-LGAD)

Resistive Silicon Detectors (RSD/AC-LGAD) are novel silicon detectors capable of both precise spatial and temporal resolution. Such sensors will be essential for the next generation of particle colliders (EIC, FCC-ee, CEPC, FCC-hh) and would enable the possibility of a 4D tracker. RSD sensors are typically fabricated with a pixel-like geometry that provides excellent spatial resolution in the x and y directions. However, in regions further from the interaction point, high spatial resolution in one direction (strip-like geometry) is often preferred to reduce the number of readout channels. For example, strip AC-LGADs are now the default option for the US electron ion collider (EIC). The second production of RSD sensors by Fondazione Bruno Kessler includes sensors with unconventional readout pad shapes that act as a mixture between strip-like and pixel-like readout. This work presents the first characterization of these new pad designs using the Transient Current Technique (TCT). The measurements demonstrate exceptional one-dimensional spatial resolution, confirming the potential of novel strip-like RSDs for future tracking systems.

physics.ins-det