arXiv Science⌕ Search

arXiv subjects

Linhan Fang

Publications and source records attributed to Linhan Fang.

14 recordsLinked to original sources

Graph Neural Network Prediction of Frequency Nadir and RoCoF Under Topology Variations

Accurate prediction of frequency dynamics under varying network topologies is essential for rapid frequency security assessment, whereas repeated electromagnetic transient (EMT) simulations are computationally intensive. This paper develops a topology-aware graph neural network with a radial basis function Kolmogorov-Arnold network (RBF-KAN) regression head, termed RK-GNN, to predict frequency nadir and maximum absolute rate of change of frequency (RoCoF). Scenarios combine load scaling, regional load redistribution, and generator redispatch with intact, N-1, and N-2 transmission topologies. After checks for network connectivity, generator reference limits, and numerical consistency, the retained scenarios are simulated in PSCAD to construct the reference dataset. The RK-GNN is evaluated against a conventional deep neural network (DNN) and a baseline GNN. On the IEEE 39-bus system, the RK-GNN reduces the mean absolute errors (MAEs) of nadir and RoCoF by 48% and 59% relative to the DNN and by 42% and 61% relative to the baseline GNN. Incorporating the bridge indicator and disturbance hop distance yields further MAE reductions of 27% and 54%. These results show that the proposed topology-aware architecture provides accurate prediction of both frequency metrics under varying topologies and substantially reduces the need for repeated EMT simulations.

eess.SY↗

A Topology-Aware Neural Network for Fault Location With Missing Measurements

This paper proposes a topology-aware neural network-based fault locator (TANFL) for radial distribution feeders, which uses voltage and current phasors obtained after the decay of fault induced transients, as well as feeder connection relationships and line parameters, as inputs. The shared bus encoder, bus readout module, and gated line readout module work together to identify the faulty bus or line and estimate the continuous fault location on the selected line. During training, explicit missing data indicators and random bus data block masking are introduced, enabling a single trained model to handle both complete measurement sets and scenarios where any permitted bus measurement device fails. On the IEEE 15 bus feeder, this paper compares TANFL with a conventional multilayer perceptron (MLP) and the formula-based localization method under identical data, measurement availability scenarios, and evaluation metrics. On the test partition, TANFL outperforms the conventional MLP; with complete measurements, its line fault location performance is slightly lower than that of the formula-based method, but in the average results for scenarios with one missing bus measurement block, its accuracy is the highest among the three methods at a 5% tolerance.

eess.SY↗

Service-Aware Hosting Capacity Assessment of Edge Data Centers with Workload Flexibility

The growing demand for edge computing, content delivery, and AI services is driving the interconnection of edge data centers (DCs) with distribution networks. Before interconnection, utilities evaluate how much DC capacity can be accommodated without violating feeder current and voltage limits. Fixed peak load representations can overlook service dependent demand patterns, cooling related facility demand, and delay tolerant computing tasks. This paper develops a hosting capacity (HC) assessment model for edge DCs with shiftable workload scheduling. Three representative types are considered: mobile edge computing (MEC), content delivery network (CDN), and AI DCs. Facility demand is modeled by combining fixed base demand, service driven demand, prescribed cooling-overhead coefficient, and a shiftable workload component. Workload execution is optimized under arrival causality, maximum delay, daily energy balance constraints, and the resulting active and reactive loads are embedded in a distribution power flow model. Compared with the baseline without load shifting, the maximum bus level HC gain on the IEEE 33-bus system reaches 4.46% for MEC DCs and 9.89% for AI DCs, while CDN case shows negligible gain under the assumed cache management windows.

eess.SY↗

Impact of Security Modeling Fidelity on Hyperscale Data Center Hosting Capacity Assessment

This paper assesses hyperscale data center hosting capacity in transmission grids. Hosting capacity (HC) analysis quantifies the maximum additional load a bus can accommodate without violating operational constraints. This paper defines data center HC as the maximum time-invariant active power demand at a single target bus over a 24-hour peak-day horizon, and evaluates it under four models of increasing fidelity (i.e., the extent to which the model enforces real-world operational security requirements) on the modified IEEE 24-bus system: (i) DC optimal power flow (DC-OPF) without unit commitment (UC), (ii) basic SCUC (security-constrained unit commitment) without reliability constraints, (iii) SCUC with spinning reserve, and (iv) N-SCUC with both reserve and branch-contingency security. Comparing these models quantifies the impact of unit commitment, reserve requirements, and N-1 security on bus-level HC estimates. The N-SCUC yields an average HC of 444 MW; omitting N-1 security raises this to 532 MW, a 19.8% overestimation. The DC-OPF and basic SCUC models further overestimate HC, indicating a trade-off between model complexity and estimation accuracy.

eess.SY↗

Active Power Thermal Feasibility Assessment of EV Integration with DER Scheduling and Distribution Network Reconfiguration

The rapid growth of electric vehicle (EV) adoption poses operational and economic challenges for distribution systems, including increased line loading and network congestion. As a practical near-term alternative to infrastructure reinforcement, distribution network topology reconfiguration (DNTR) can redistribute power flows, reduce operating costs, and improve operational flexibility. This paper presents a data driven operational feasibility framework for evaluating EV integration under increasing demand levels across four configurations: standard distribution network (SDN), SDN with DNTR (SDNTR), SDN with distributed energy resources (SDN-DER), and SDNTR with DERs (SDNTR-DER). Smart meter derived EV charging behavior is used to construct nodal EV demand profiles, which are incorporated into a mixed integer linear programming based active power screening model for a modified IEEE 33 bus distribution system. Feasibility is assessed with respect to nodal active power balance, line thermal limits, radiality and connectivity, DER limits, and BESS intertemporal operation. A bisection search identifies maximum active power thermal feasible EV demand levels of 51%, 68%, 85%, and 102% for SDN, SDN-DER, SDNTR, and SDNTR-DER, respectively. The 102% result represents full residential EV adoption with a 2% additional charging demand margin. At 0% EV penetration, SDNTR-DER reduces operating cost by 54% relative to SDN, representing the baseline economic value of coordinated DER scheduling and DNTR. The reported limits represent active power thermal feasibility boundaries rather than full AC hosting capacity limits.

eess.SY↗

Net Load Forecasting with Renewable Capacity Features: A Comparison of Direct and Indirect Neural Network Methods

Renewable energy adoption has increased significantly in recent years. However, the growing penetration of renewable generation that depends on the weather introduces additional variability, making accurate net load forecasting increasingly challenging. In this study, long short-term memory (LSTM) and fully connected neural network (FCNN) models are employed to forecast net load one hour ahead using direct and indirect approaches. In the direct approach, net load is predicted directly, whereas in the indirect approach, total load, wind generation, and solar generation are predicted separately and then used to derive net load. Installed renewable generation capacity is also incorporated as an input feature to capture changes in renewable generation capability over time. A 24-hour input window and a chronological 90%/5%/5% training, validation, and test split are employed, with preprocessing fitted exclusively on the training data. On 1,754 common test timestamps, the direct FCNN slightly outperforms the indirect FCNN, whereas the indirect LSTM achieves the best overall performance, with a MAPE of 2.46%, an RMSPE of 3.59%, and an R2 of 98.7%. These results demonstrate that component-wise forecasting can improve LSTM-based net load prediction when the characteristics of renewable generation and installed capacity information are represented appropriately.

eess.SY↗

BESS Siting and Sizing to Mitigate EV Charging-Induced Voltage Violations: A Planning Space Reduction Approach

The rapid growth of electric vehicle (EV) charging can cause persistent voltage violations in distribution networks and increase the need for grid-side voltage support. This paper develops a proactive voltage management framework for planning battery energy storage systems (BESS) to mitigate EV charging-induced voltage violations. Annual EV charging profiles are generated through Monte Carlo simulation using probability distributions derived from real charging events and are incorporated into an annual voltage assessment to identify stressed operating conditions. An optimal expansion planning model then determines installation locations and capacities at minimum investment cost. To improve computational tractability, a planning space reduction (PSR) strategy combines critical period selection to reduce the chronological horizon with candidate bus screening to reduce the BESS siting space. The resulting investment decisions are evaluated through full-year operational validation on the IEEE 33-bus, IEEE 69-bus, and a 240-bus distribution system. Results show that PSR reduces solution time by up to 99.2% while matching the exhaustive benchmark in the 33-bus and 69-bus systems and limiting the objective deviation to 0.55% in the 240-bus system. The optimized BESS deployments eliminate the identified annual voltage violations and further reduce electricity purchase costs and network energy losses under increasing EV penetration.

eess.SY↗

Diagnosis-Driven Co-planning of Network Reinforcement and BESS for Distribution Grid with High Penetration of Electric Vehicles

While the rapid proliferation of electric vehicles (EVs) accelerates net-zero goals, uncoordinated charging activities impose severe operational challenges on distribution grids, including exacerbated peak loads, thermal overloading, and voltage violations. To overcome the computational intractability of jointly optimizing grid infrastructure reinforcements and Battery Energy Storage System (BESS) installations, this paper proposes a novel three-stage Diagnosis-Driven Co-Planning (DDCP) framework. The methodology integrates a Violation Detection and Quantification (VDQ) model to systematically identify system breaches, and a Violation Mitigation-Based Planning (VMBP) model for optimal BESS allocation. Specifically, Stage I of the DDCP framework diagnoses critical bottleneck lines that render standalone BESS solutions infeasible; Stage II executes targeted physical upgrades exclusively on these bottlenecks; and Stage III finalizes the optimal BESS deployment on the updated network topology. Furthermore, this study quantifies the EV hosting capacity thresholds before and after BESS integration across varying EV adoption rates and base voltages. Finally, a comprehensive comparative analysis evaluates four mitigation approaches: the VDQ-driven cable upgrade (VCU) model, the VMBP model, system-wide voltage uprating, and the proposed DDCP framework. The results demonstrate that the DDCP framework not only resolves the complex joint-optimization hurdle but also achieves superior techno-economic performance in addressing high-EV-penetration challenges.

eess.SY↗

Violation-Informed Spatio-Temporal Adaptive Targeting Framework for EV-Driven Distribution System Expansion Planning

The rapid adoption of electric vehicles (EVs) can cause severe voltage drops and line current overloads in distribution networks, creating an urgent need for scalable expansion planning methods. This paper proposes a computationally efficient violation-informed spatio-temporal adaptive targeting (STAT) framework for EV-driven distribution system expansion planning. The framework first identifies potential voltage and current violations through a violation analysis model, and then mitigates them through a joint optimal expansion planning model that co-optimizes investment decisions for line reconductoring, shunt capacitors, and battery energy storage systems. To reduce computational burden, the proposed STAT-temporal criticality assessment (STAT-TCA) method extracts primitive stress events from annual operating data, derives an initial set of candidate planning horizons from signature-consistent segments, and selects a final transferable critical horizon set through cross-horizon validation based on optimization feasibility and cost. Meanwhile, the proposed STAT-adaptive spatial targeting (STAT-AST) method constructs device-specific spatial features for BESS and SC siting to retain compact yet high-impact candidate bus sets. Case studies on 33-bus and 240-bus distribution systems demonstrate that the proposed STAT framework can substantially reduce the temporal and spatial planning dimensions while preserving planning fidelity. Full-year validation further confirms that the resulting investment plans can eliminate EV-induced voltage and thermal violations while maintaining feasible BESS operations.

eess.SY↗

Hosting Capacity Assessment and Enhancement for Edge Data Centers in Active Distribution Networks

With the increasing demand for edge computing and AI-driven workloads, integrating small and medium-sized edge data centers into distribution networks has become increasingly important. This paper investigates the hosting capacity of distribution networks for data center integration and identifies the key physical mechanisms that limit the maximum allowable data center load. The baseline analysis shows that data center hosting capacity varies significantly across candidate buses due to network topology and electrical distance. Three dominant limiting mechanisms are identified: current-constrained locations, voltage-constrained locations, and mixed-constrained locations where both current loading and voltage deviation jointly affect hosting capacity. To increase the hosting capacity, this study evaluates multiple flexible resources, including battery energy storage systems (BESS), dispatchable distributed generators (DDG), and static synchronous compensators (STATCOM). Numerical results demonstrate that these resources provide complementary benefits through active power support, sustained local generation, and reactive power compensation, effectively expanding data center hosting capacity in distribution systems.

eess.SY↗

Grid Operational Benefit Analysis of Data Center Spatial Flexibility: Congestion Relief, Renewable Energy Curtailment Reduction, and Cost Saving

Data centers are facilities housing computing infrastructure for processing and storing digital information. The rapid expansion of artificial intelligence is driving unprecedented growth in data center capacity, with global electricity demand from data centers projected to double by 2026. This growth creates substantial challenges for power transmission networks, as large concentrated loads can cause congestion and threaten grid reliability. Meanwhile, the intermittent nature of solar and wind generation requires flexible resources to maintain grid reliability and minimize curtailment. This paper assesses whether data center spatial flexibility-the ability to migrate computational workloads geographically-can serve as a grid resource to address these challenges. An optimal power flow model is developed to co-optimize generation dispatch, security reserves, and flexible data center loads. Case studies on a modified IEEE 73-bus system show that inflexible data center placement can lead to severe transmission violations, with line overloads reaching 30.1%. Enabling spatial flexibility mitigates these violations in the studied scenarios and restores system feasibility. This flexibility also reduces solar curtailment by up to 61.0% by strategically reallocating load to solar-rich areas. The results suggest that spatial flexibility offers a viable approach to defer transmission upgrades and enhance renewable utilization.

eess.SY↗

Data-Driven EV Charging Load Profile Estimation and Typical EV Daily Load Dataset Generation

Widespread electric vehicle (EV) adoption introduces new challenges for distribution grids due to large, localized load increases, stochastic charging behavior, and limited data availability. This paper proposes two data-driven methods to estimate residential EV charging profiles using real-world customer meter data from CenterPoint Energy serving the Houston area. The first approach applies a least-squares estimation to extract average charging rates by comparing aggregated EV and non-EV meter data, enabling a statistical method for starting and ending charge times. The second method isolates EV load from meter profiles and applies a kernel density estimation (KDE) to develop a probabilistic charging model. Both methods produce a distinct "u-shaped" daily charging profile, with most charging occurring overnight. The validated profiles offer a scalable tool for utilities to better anticipate EV-driven demand increases and support proactive grid planning.

eess.SY↗

A Black Start Strategy for Hydrogen-integrated Renewable Grids with Energy Storage Systems

With the increasing integration of renewable energy, the reliability and resilience of modern power systems are of vital significance. However, large-scale blackouts caused by natural disasters or equipment failures remain a significant threat, necessitating effective restoration strategies. This study proposes novel black start models for modern power systems that integrate fuel cells and battery storage, recognizing their distinct characteristics and contributions to grid resilience. These models specifically address the restoration of electrical grids, including the energization paths and time of the transmission network, while accounting for the unique power output traits of fuel cells and the energy storage capacity of batteries as black start resources. Black start simulations, comparing the generator startup sequence (GSUS) with fuel cell versus battery systems, are performed on the IEEE 39-bus system. We conduct sensitivity analyses on fuel cell capacity, battery storage capacity, initial state of charge (SOC), and resource locations to identify optimal scenarios for black start operations.

eess.SY↗

Analysis of Learning-based Offshore Wind Power Prediction Models with Various Feature Combinations

Accurate wind speed prediction is crucial for designing and selecting sites for offshore wind farms. This paper investigates the effectiveness of various machine learning models in predicting offshore wind power for a site near the Gulf of Mexico by analyzing meteorological data. After collecting and preprocessing meteorological data, nine different input feature combinations were designed to assess their impact on wind power predictions at multiple heights. The results show that using wind speed as the output feature improves prediction accuracy by approximately 10% compared to using wind power as the output. In addition, the improvement of multi-feature input compared with single-feature input is not obvious mainly due to the poor correlation among key features and limited generalization ability of models. These findings underscore the importance of selecting appropriate output features and highlight considerations for using machine learning in wind power forecasting, offering insights that could guide future wind power prediction models and conversion techniques.

eess.SP↗