arXiv Science⌕ Search

arXiv subjects

Lingtao Yu

Publications and source records attributed to Lingtao Yu.

3 recordsLinked to original sources

Instance-preserving graded semantic reporting for surgical action triplets

Complete-or-reject reporting of surgical action triplets can discard a correctly identified instrument and action when the target is uncertain. We introduce instance-preserving graded semantic reporting, which separates instance selection from the choice of semantic detail. Each selected instance retains its predicted mask and labels while hierarchical correctness scores guide instrument (I), instrument-verb (IV), or complete instrument-verb-target (IVT) reporting. The utility-increment rule DELTA weighs the expected gain from finer reporting against its error cost. We compare three decision rules on 5,641 test frames from eight surgical videos using fixed predictions and scores. At the 10% development calibration target, DELTA retains correct partial reports for 80.0% of candidates rejected by a matched complete-or-reject baseline (5,329/6,662). Adding IV increases source-normalized weighted correct-report yield by 19.13 to 23.13 per 100 frames across all three rules relative to separately recalibrated I/IVT controls. Weighted reporting risk changes by -0.77 to +1.01 percentage points, with complete correct-triplet counts unchanged or reduced. Graded reporting makes partial surgical predictions available as localized descriptions, with an explicit trade-off between report utility and completeness.

cs.CV↗

Selective Surgical Action-Center Localization:Retaining Localization Gains through Supervised Scoring

Surgical action-center localization requires both an accurate reference point and a decision about whether to report it. When frames with and without a reportable center are mixed, the benefit of improved localization depends on which correct candidates survive selection. We present a selective localization pipeline combining heatmap and coordinate supervision with a logistic-regression scorer. The scorer learns to identify predictions with a reportable center and a localization error within a specified tolerance. The internal evaluation uses 5,000 frames from 50 surgical sources, five source-grouped folds and two random seeds. Matched locator and scoring comparisons track correct candidates and their rejection. At an 80% acceptance quota per source and a tolerance of 0.10 times the image diagonal, our method retains 46.08 correct outputs per 100 inputs. The baseline locator with the same scoring approach retains 44.20. The gain is 1.88 (descriptive 95% source-paired bootstrap interval, 0.94 to 2.79). Under entropy-based selection, increased rejection of correct predictions offsets the higher supply of correct predictions on average. For the coordinate-supervised locator, supervised scoring reduces these rejections from 6.15 to 2.99 per 100 inputs. Evaluating retained correct outputs reveals whether a selection rule preserves or erodes an improvement in localization.

cs.CV↗

A Method for Self-Service Rehabilitation Training of Human Lower Limbs

In recent years, the research of rehabilitation robot technology has become a hotspot in the field of rehabilitation medicine engineering and robotics. To assist active rehabilitation in patients with unilateral lower extremity injury, we propose a new self-service rehabilitation training method to control the injured lower extremity through its contralateral healthy upper limbs. Firstly, the movement data of upper limbs and lower limbs of healthy people in normal walking state are obtained by gait measurement experiment. Secondly, the eigenvectors of upper limb and lower limb movements in a single movement cycle are extracted respectively. Thirdly, the linear mapping relationship between the upper limbs movement and the lower limbs movement is identified using the least squares method. Finally, the simulation experiment of self-service rehabilitation training is implemented on MATLAB/Simulink. The results indicate that the identified linear mapping model can achieve good accuracy and adaptability. The self-service rehabilitation training method is effective for helping patients with unilateral limb injury to make rehabilitation training on themselves.

cs.RO↗