arXiv ScienceSearch

arXiv subjects

L. Gross

Publications and source records attributed to L. Gross.

3 recordsLinked to original sources

Test Beam Performance Measurements for the Phase I Upgrade of the CMS Pixel Detector

A new pixel detector for the CMS experiment was built in order to cope with the instantaneous luminosities anticipated for the Phase~I Upgrade of the LHC. The new CMS pixel detector provides four-hit tracking with a reduced material budget as well as new cooling and powering schemes. A new front-end readout chip mitigates buffering and bandwidth limitations, and allows operation at low comparator thresholds. In this paper, comprehensive test beam studies are presented, which have been conducted to verify the design and to quantify the performance of the new detector assemblies in terms of tracking efficiency and spatial resolution. Under optimal conditions, the tracking efficiency is $99.95\pm0.05\,\%$, while the intrinsic spatial resolutions are $4.80\pm0.25\,μ\mathrm{m}$ and $7.99\pm0.21\,μ\mathrm{m}$ along the $100\,μ\mathrm{m}$ and $150\,μ\mathrm{m}$ pixel pitch, respectively. The findings are compared to a detailed Monte Carlo simulation of the pixel detector and good agreement is found.

physics.ins-det

Temperature dependence of the nonlocal voltage in an Fe/GaAs electrical spin injection device

The nonlocal spin resistance is measured as a function of temperature in a Fe/GaAs spin-injection device. For nonannealed samples that show minority-spin injection, the spin resistance is observed up to room temperature and decays exponentially with temperature at a rate of 0.018\,K$^{-1}$. Post-growth annealing at 440\,K increases the spin signal at low temperatures, but the decay rate also increases to 0.030\,K$^{-1}$. From measurements of the diffusion constant and the spin lifetime in the GaAs channel, we conclude that sample annealing modifies the temperature dependence of the spin transfer efficiency at injection and detection contacts. Surprisingly, the spin transfer efficiency increases in samples that exhibit minority-spin injection.

cond-mat.mes-hall

Front-End electronics configuration system for CMS

The four LHC experiments at CERN have decided to use a commercial SCADA (Supervisory Control And Data Acquisition) product for the supervision of their DCS (Detector Control System). The selected SCADA, which is therefore used for the CMS DCS, is PVSS II from the company ETM. This SCADA has its own database, which is suitable for storing conventional controls data such as voltages, temperatures and pressures. In addition, calibration data and FE (Front-End) electronics configuration need to be stored. The amount of these data is too large to be stored in the SCADA database [1]. Therefore an external database will be used for managing such data. However, this database should be completely integrated into the SCADA framework, it should be accessible from the SCADA and the SCADA features, e.g. alarming, logging should be benefited from. For prototyping, Oracle 8i was selected as the external database manager. The development of the control system for calibration constants and FE electronics configuration has been done in close collaboration with the CMS tracker group and JCOP (Joint COntrols Project)(1). (1)The four LHC experiments and the CERN IT/CO group has merged their efforts to build the experiments controls systems and set up the JCOP at the end of December, 1997 for this purpose.

physics.ins-det