arXiv ScienceSearch

arXiv subjects

Kurt Gibble

Publications and source records attributed to Kurt Gibble.

At least 19 recordsLinked to original sources

Lattice Light Shift Evaluations In a Dual-Ensemble Yb Optical Lattice Clock

In state-of-the-art optical lattice clocks, beyond-electric-dipole polarizability terms lead to a break-down of magic wavelength trapping. In this Letter, we report a novel approach to evaluate lattice light shifts, specifically addressing recent discrepancies in the atomic multipolarizability term between experimental techniques and theoretical calculations. We combine imaging and multi-ensemble techniques to evaluate lattice light shift atomic coefficients, leveraging comparisons in a dual-ensemble lattice clock to rapidly evaluate differential frequency shifts. Further, we demonstrate application of a running wave field to probe both the multipolarizability and hyperpolarizability coefficients, establishing a new technique for future lattice light shift evaluations.

physics.atom-ph

Laser-cooling Cadmium Bosons and Fermions with Near Ultraviolet Triplet Excitations

Cadmium is laser-cooled and trapped with excitations to triplet states with UVA light, first using only the $67\,$kHz wide $326\,$nm intercombination line and subsequently, for large loading rates, the $25\,$MHz wide $361\,$nm $\,^3P_2$$\,\rightarrow\,$$\,^3D_3$ transition. Eschewing the hard UV $229\,$nm $^1S_0$$\,\rightarrow$$\,^1P_1$ transition, only small magnetic fields gradients, less than $6\,$G$\,$cm$^{-1}$, are required enabling a 100\% transfer of atoms from the $361\,$nm trap to the $326\,$nm narrow-line trap. All 8 stable cadmium isotopes are straightforwardly trapped, including two nuclear-spin-$\frac{1}{2}$ fermions that require no additional repumping. We observe evidence of $^3P_2$ collisions limiting the number of trapped metastable atoms, report isotope shifts for $^{111}$Cd and $^{113}$Cd of the $326\,$nm $^1S_0$$\,\rightarrow$$\,^3P_1$, $480\,$nm $^3P_1$$\,\rightarrow$$\,^3S_1$, and $361\,$nm $^3P_2$$\,\rightarrow$$\,^3D_3$ transitions, and measure the $^{114}$Cd 5s5p$\,^3P_2$$\,\rightarrow\,$5s5d$\,^3D_3$ transition frequency to be $830\,096\,573(15)\,$MHz.

physics.atom-ph

Clock-line-mediated Sisyphus Cooling

We demonstrate sub-recoil Sisyphus cooling using the long-lived $^{3}\mathrm{P}_{0}$ clock state in alkaline-earth-like ytterbium. A 1388 nm optical standing wave nearly resonant with the $^{3}\textrm{P}_{0}$$\,\rightarrow$$\,^{3}\textrm{D}_{1}$ transition creates a spatially periodic light shift of the $^{3}\textrm{P}_{0}$ clock state. Following excitation on the ultranarrow clock transition, we observe Sisyphus cooling in this potential, as the light shift is correlated with excitation to $^{3}\textrm{D}_{1}$ and subsequent spontaneous decay to the $^{1}\textrm{S}_{0}$ ground state. We observe that cooling enhances the loading efficiency of atoms into a 759 nm magic-wavelength one-dimensional (1D) optical lattice, as compared to standard Doppler cooling on the $^{1}\textrm{S}_{0}$$\,\rightarrow\,$$^{3}\textrm{P}_{1}$ transition. Sisyphus cooling yields temperatures below 200 nK in the weakly confined, transverse dimensions of the 1D optical lattice. These lower temperatures improve optical lattice clocks by facilitating the use of shallow lattices with reduced light shifts, while retaining large atom numbers to reduce the quantum projection noise. This Sisyphus cooling can be pulsed or continuous and is applicable to a range of quantum metrology applications.

physics.atom-ph

Ratchet Loading and Multi-Ensemble Operation in an Optical Lattice Clock

We demonstrate programmable control over the spatial distribution of ultra-cold atoms confined in an optical lattice. The control is facilitated through a combination of spatial manipulation of the magneto-optical trap and atomic population shelving to a metastable state. We first employ the technique to load an extended (5 mm) atomic sample with uniform density in an optical lattice clock, reducing atomic interactions and realizing remarkable frequency homogeneity across the atomic cloud. We also prepare multiple spatially separated atomic ensembles and realize multi-ensemble clock operation within the standard one-dimensional (1D) optical lattice clock architecture. Leveraging this technique, we prepare two oppositely spin-polarized ensembles that are independently addressable, offering a platform for implementing spectroscopic protocols for enhanced tracking of local oscillator phase. Finally, we demonstrate a relative fractional frequency instability at one second of $2.4(1) \times10^{-17}$ between two ensembles, useful for characterization of intra-lattice differential systematics.

physics.atom-ph

A many-channel FPGA control system

We describe a many-channel experiment control system based on a field-programmable gate array (FPGA). The system has 16 bit resolution on 10 analog 100 MS/s input channels, 14 analog 100 MS/s output channels, 16 slow analog input and output channels, dozens of digital inputs and outputs, and a touchscreen display for experiment control and monitoring. The system can support 10 servo loops with 155 ns latency and MHz bandwidths, in addition to as many as 30 lower bandwidth servos. We demonstrate infinite-impulse-response (IIR) proportional-integral-differential (PID) filters with 30 ns latency by using only bit-shifts and additions. These IIR filters allow timing margin at 100 MS/s and use fewer FPGA resources than straightforward multiplier-based filters, facilitating many servos on a single FPGA. We present several specific applications: H\"ansch-Couillaud laser locks with automatic lock acquisition and a slow dither correction of lock offsets, variable duty cycle temperature servos, and the generation of multiple synchronized arbitrary waveforms.

physics.ins-det

Cold Atoms in Space: Community Workshop Summary and Proposed Road-Map

We summarize the discussions at a virtual Community Workshop on Cold Atoms in Space concerning the status of cold atom technologies, the prospective scientific and societal opportunities offered by their deployment in space, and the developments needed before cold atoms could be operated in space. The cold atom technologies discussed include atomic clocks, quantum gravimeters and accelerometers, and atom interferometers. Prospective applications include metrology, geodesy and measurement of terrestrial mass change due to, e.g., climate change, and fundamental science experiments such as tests of the equivalence principle, searches for dark matter, measurements of gravitational waves and tests of quantum mechanics. We review the current status of cold atom technologies and outline the requirements for their space qualification, including the development paths and the corresponding technical milestones, and identifying possible pathfinder missions to pave the way for missions to exploit the full potential of cold atoms in space. Finally, we present a first draft of a possible road-map for achieving these goals, that we propose for discussion by the interested cold atom, Earth Observation, fundamental physics and other prospective scientific user communities, together with ESA and national space and research funding agencies.

astro-ph.IM

Fundamental Physics with a State-of-the-Art Optical Clock in Space

Recent advances in optical atomic clocks and optical time transfer have enabled new possibilities in precision metrology for both tests of fundamental physics and timing applications. Here we describe a space mission concept that would place a state-of-the-art optical atomic clock in an eccentric orbit around Earth. A high stability laser link would connect the relative time, range, and velocity of the orbiting spacecraft to earthbound stations. The primary goal for this mission would be to test the gravitational redshift, a classical test of general relativity, with a sensitivity 30,000 times beyond current limits. Additional science objectives include other tests of relativity, enhanced searches for dark matter and drifts in fundamental constants, and establishing a high accuracy international time/geodesic reference.

gr-qc

Atomic Clock Measurements of Quantum Scattering Phase Shifts Spanning Feshbach Resonances at Ultralow Fields

We use an atomic fountain clock to measure quantum scattering phase shifts precisely through a series of narrow, low-field Feshbach resonances at average collision energies below $1\,\mu$K. Our low spread in collision energy yields phase variations of order $\pm \pi/2$ for target atoms in several $F,m_F$ states. We compare them to a theoretical model and establish the accuracy of the measurements and the theoretical uncertainties from the fitted potential. We find overall excellent agreement, with small statistically significant differences that remain unexplained.

physics.atom-ph

Comment on "Frequency shifts in NIST Cs primary frequency standards due to transverse rf field gradients"

We discuss the theoretical treatment of the microwave lensing frequency shift of the NIST-F1 and F2 atomic fountain clocks by Ashby et al. [Phy. Rev. A. 91, 033624 (2015)]. The shifts calculated by NIST are much smaller than the previously evaluated microwave lensing frequency shifts of other clocks contributing to International Atomic Time. We identify several fundamental problems in the NIST treatment and demonstrate that each significantly affects their results. We also show a smooth transition of microwave lensing frequency shifts to the photon recoil shift for large wave packets.

physics.atom-ph

Comment on "first accuracy evaluation of NIST-F2"

We discuss the treatment of the systematic frequency shifts due to microwave lensing and distributed cavity phase in "First accuracy evaluation of NIST-F2" 2014 Metrologia 51 174-182. We explain that the microwave lensing frequency shift is generally non-zero and finite in the limit of no applied microwave field. This systematic error was incorrectly treated and we find that it contributes a significant frequency offset. Accounting for this shift implies that the measured microwave amplitude dependence (e.g due to microwave leakage) is comparable to the total reported inaccuracy. We also discuss the importance of vertically aligning the fountain perpendicular to the axis of the cavity feeds, when the cavity has only two independent feeds. Finally, we note that background gas collisions have a different behavior for cold clock atoms than for clock atoms at room-temperature, and therefore room temperature measurements do not directly apply to laser-cooled clocks.

physics.atom-ph

Scattering of Cold Atom Coherences by Hot Atoms: Frequency Shifts from Background Gas Collisions

Frequency shifts from background gas collisions currently contribute significantly to the inaccuracy of atomic clocks. Because nearly all collisions with room-temperature background gases that transfer momentum eject the cold atoms from the clock, the interference between the scattered and unscattered waves in the forward direction dominates these frequency shifts. We show they are ~10 times smaller than in room-temperature clocks and that van der Waals interactions produce the cold-atom background-gas shift. General considerations allow the loss of Ramsey fringe amplitude to bound this frequency shift.

physics.atom-ph

S-Wave Collisional Frequency Shift of a Fermion Clock

We report an s-wave collisional frequency shift of an atomic clock based on fermions. In contrast to bosons, the fermion clock shift is insensitive to the population difference of the clock states, set by the first pulse area in Ramsey spectroscopy, \theta_1. The fermion shift instead depends strongly on the second pulse area \theta_2. It allows the shift to be canceled, nominally at \theta_2 = \pi/2, but correlations shift the null to slightly larger \theta_2. The shift applies to optical lattice clocks and increases with the spatial inhomogeneity of the clock excitation field, naturally large at optical frequencies.

physics.atom-ph

Direct Observation of Resonant Scattering Phase Shifts and their Energy Dependence

We scan the collision energy of two clouds of cesium atoms between 12 and 50 $\mu$K in atomic fountain clock. By directly detecting the difference of s-wave scattering phase shifts, we observe a rapid variation of a scattering phase shift through a series of Feshbach resonances. At the energies we use, resonances that overlap at threshold become resolved. Our statistical phase uncertainty of 8 mrad can be improved in future precision measurements of Feshbach resonances to accurately determine the Cs-Cs interactions, which may provide stringent limits on the time variation of fundamental constants.

physics.atom-ph

Progress in Atomic Fountains at LNE-SYRTE

We give an overview of the work done with the Laboratoire National de M\'etrologie et d'Essais-Syst\`emes de R\'ef\'erence Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

physics.atom-ph

Spin waves and Collisional Frequency Shifts of a Trapped-Atom Clock

We excite spin-waves with spatially inhomogeneous pulses and study the resulting frequency shifts of a chip-scale atomic clock of trapped $^{87}$Rb. The density-dependent frequency shifts of the hyperfine transition simulate the s-wave collisional frequency shifts of fermions, including those of optical lattice clocks. As the spin polarizations oscillate in the trap, the frequency shift reverses and it depends on the area of the second Ramsey pulse, exhibiting a predicted beyond mean-field frequency shift. Numerical and analytic models illustrate the observed behaviors.

physics.atom-ph

Rydberg Spectroscopy in an Optical Lattice: Blackbody Thermometry for Atomic Clocks

We show that optical spectroscopy of Rydberg states can provide accurate {\em in situ} thermometry at room-temperature. Transitions from a metastable state to Rydberg states with principal quantum numbers of 25 to 30 have 200 times larger fractional frequency sensitivities to blackbody radiation than the Strontium clock transition. We demonstrate that magic wavelength lattices exist for both Strontium and Ytterbium transitions between the metastable and Rydberg states. Frequency measurements of Rydberg transitions with $10^{-16}$ accuracy provide $10 \, \mathrm{mK}$ resolution and yield a blackbody uncertainty for the clock transition of $10^{-18}$.

quant-ph

Improved accuracy of the NPL-CsF2 primary frequency standard: evaluation of distributed cavity phase and microwave lensing frequency shifts

We evaluate the distributed cavity phase and microwave lensing frequency shifts, which were the two largest sources of uncertainty for the NPL-CsF2 cesium fountain clock. We report measurements that confirm a detailed theoretical model of the microwave cavity fields and the frequency shifts of the clock that they produce. The model and measurements significantly reduce the distributed cavity phase uncertainty to $1.1 \times 10^{-16}$. We derive the microwave lensing frequency shift for a cylindrical cavity with circular apertures. An analytic result with reasonable approximations is given, in addition to a full calculation that indicates a shift of $6.2 \times 10^{-17}$. The measurements and theoretical models we report, along with improved evaluations of collisional and microwave leakage induced frequency shifts, reduce the frequency uncertainty of the NPL-CsF2 standard to $2.3 \times 10^{-16}$, nearly a factor of two lower than its most recent complete evaluation.

quant-ph

Evaluation of Doppler Shifts to Improve the Accuracy of Primary Atomic Fountain Clocks

We demonstrate agreement between measurements and ab initio calculations of the frequency shifts caused by distributed cavity phase variations in the microwave cavity of a primary atomic fountain clock. Experimental verification of the finite element models of the cavities gives the first quantitative evaluation of this leading uncertainty and allows it to be reduced to delta nu / nu = 8.4\times10^-17. Applying these experimental techniques to clocks with improved microwave cavities will yield negligible distributed cavity phase uncertainties, less than \pm1\times10^-17.

quant-ph