arXiv Science⌕ Search

arXiv subjects

Kesavaraja C

Publications and source records attributed to Kesavaraja C.

3 recordsLinked to original sources

A Multiobjective Optimization Framework for Sensor Array Design in Magnetocardiography

Magnetocardiography (MCG) noninvasively measures cardiac magnetic fields. Conventional cryogenic systems use fixed multichannel arrays, whereas room-temperature sensors enable flexible placement to reduce array size and measurement redundancy. The present study aims at developing a scheme to identify the optimal sensor placements by utilizing three methodological sensor optimization frameworks such as physics driven, experimental data driven and a hybrid combination of both. The physics-driven method optimizes continuous planar coordinates using D-optimality, spatial correlation, and leastsquares error. The data-driven method uses measured spatiotemporal fields and pole-geometry metrics, while the hybrid method integrates both approaches. The evaluation is performed using training objective, Pearson correlation, normalized root-meansquare error (NRMSE) and pole separation(mm), orientation(°) and trajectory(mm) errors, where physics-driven optimization identified 16 sensors with a correlation of 0.9914 and an NRMSE of 0.0139, with pole separation, orientation, and trajectory errors of 3.71 mm, 1.38°, and 3.55 mm, respectively. Data-driven optimization shows diminishing improvements beyond 17 sensors, achieving correlation 0.9840, NRMSE 0.0035, and pole errors of approximately 4.30 mm, 1.70°, and 6.80 mm. The hybrid method achieves correlation 0.9945 and NRMSE 0.0201 with 14 sensors, reducing sensor count by 12.5% relative to the physics-driven configuration. Its pole errors of 6.50 mm, 2.31°, and 7.50 mm satisfy the study-defined thresholds, balancing array compactness with magnetic-field morphology preservation. These results show that optimized placement helps alleviate the complexity of data redundancy and enhances the performance of MCG as a routine cost-effective clinical measurement.

cond-mat.stat-mech↗

A Signal Analysis Framework for Unshielded Room-Temperature Magnetocardiography

Room-temperature, unshielded recording of cardiac magnetic signals has remained a significant challenge since the inception of magnetocardiography (MCG). In this work, we present an MCG system based on optically pumped magnetometers (OPMs) designed to operate in ambient magnetic environments and acquire adult human cardiac magnetic fields, without the need for active or passive shielding. The system operates in a gradiometer configuration, achieving background-noise cancellation with a common-mode rejection ratio (CMRR) of 31 dB and a gradient sensitivity of 314 $\mathrm{fT/cm/\sqrt{Hz}}$. MCG signals were acquired sequentially at 16 locations across the anterior thorax, and a comprehensive signal-analysis framework incorporating wavelet multiscale principal component analysis (WMSPCA) filtering and signal quality estimation (SQE) scoring was developed to enhance signal quality. This framework yielded a QRS complex signal-to-noise ratio (SNR) of $28.56 \pm 5.61$ dB across all measurement locations. These results demonstrate the feasibility of performing clinical-grade MCG in unshielded, real-world magnetic environments, with consistent morphological fidelity across the QRS complex and T-wave segments. This work represents a meaningful step toward the practical deployment of OPM-based MCG systems in hospital and point-of-care settings.

cond-mat.stat-mech↗

Magnetocardiography measurements using an optically pumped magnetometer under ambient conditions

In this work, we report the development of a rubidium-based single-beam scalar optically pumped magnetometer (OPM) and demonstrate its application in measuring human cardiac magnetic fields in an unshielded environment. The developed magnetometers exhibit a noise floor below 15 pT/sqrt(Hz) in the frequency range of 1 to 35 Hz, with a measurement bandwidth of 100 Hz. When operated in a gradiometric configuration, the noise floor is further reduced to below 3 pT/sqrt(Hz) over the same frequency range. Magnetocardiography (MCG) signals were recorded at five different locations across the thorax. A clear polarity reversal of the QRS complex was observed across these measurement positions, confirming the spatial sensitivity of the system. The proposed system shows strong potential for clinical diagnostics, offering valuable physiological information through non-contact MCG measurements

cond-mat.stat-mech↗