arXiv Science⌕ Search

arXiv subjects

Keiichiro Toda

Publications and source records attributed to Keiichiro Toda.

15 recordsLinked to original sources

Femtosecond-to-millisecond holographic imaging of laser ablation dynamics

Femtosecond laser ablation redistributes optically deposited energy across electronic, structural, mechanical, and thermal degrees of freedom over timescales from femtoseconds to milliseconds. However, these coupled processes are usually measured in separate temporal ranges and through different observables, limiting quantitative comparison between early transient dynamics, residual heating, and final morphology. Here we introduce pump-probe holographic imaging that reconstructs amplitude- and phase-resolved optical fields across this full temporal range under matched imaging conditions. Applied to deep-ultraviolet femtosecond ablation of BK7 glass, the method captures the transition from early excitation and removal-stage dynamics to residual substrate heating and permanent modification. Differential phase analysis isolates sub-nanosecond evolution of the transient ablating layer and microsecond residual heating after material removal. Above the ablation threshold, crater depth increases with fluence, whereas the residual thermal signal saturates, indicating that additional absorbed energy is preferentially partitioned into material removal and ablation-related processes rather than retained as substrate heat. These results identify fluence-dependent energy partitioning as a dynamical basis of low-heat-affected femtosecond processing and establish holographic imaging as a route to tracking laser-driven nonequilibrium material transformations.

physics.optics↗

A unified framework for sensitivity comparison across stimulated Raman, stimulated Raman photothermal, and mid-infrared photothermal microscopy

Label-free vibrational microscopy based on Raman scattering and mid-infrared (MIR) absorption has advanced biological imaging through the development of diverse high-sensitivity modalities. However, rigorous sensitivity comparisons across these techniques remain lacking. Here, we establish a unified theoretical framework for quantitatively comparing the shot-noise-limited sensitivities of stimulated Raman scattering (SRS), MIR photothermal (MIP), and stimulated Raman photothermal (SRP) microscopy. The framework is built on two quantities: an effective absorption coefficient, which places SRS on the same footing as linear absorption, and a photothermal (PT) factor, which isolates the contribution specific to PT readout. Using experimentally realistic parameters, we show that MIR absorption coefficients for representative polar vibrational modes are typically about two orders of magnitude larger than the effective absorption coefficients of SRS, even for strong off-resonant Raman bands. In MIP, however, this intrinsic advantage is partly offset by a small PT factor, limiting the net sensitivity gain over SRS to several-fold and, at most, about one order of magnitude. In SRP, by contrast, burst-pulse thermal accumulation substantially increases the PT factor. Under ideal shot-noise-limited conditions with matched per-pulse excitation-energy conditions in water, SRP is predicted to provide sensitivities several-fold higher than those of SRS and to approach those of MIP. This framework provides a common basis for sensitivity assessment across vibrational imaging modalities and clarifies how absorption strength, photothermal accumulation, and readout conditions determine the practical advantages of each modality.

physics.optics↗

Mid-infrared photothermal imaging flow cytometry

Imaging flow cytometry (IFC) enables high-throughput single-cell analysis but largely relies on fluorescence labeling to obtain molecular specificity. Label-free vibrational imaging can provide intrinsic chemical contrast, yet coherent Raman-based methods interrogate only a limited axial volume, which restricts quantitative whole-cell analysis under flow. Mid-infrared photothermal (MIP) microscopy offers a promising route to overcome this limitation by combining linear mid-infrared (MIR) absorption-based chemical contrast with visible-light detection, allowing chemical imaging of a broader axial volume of each cell in a wide-field configuration. However, applying MIP microscopy to rapidly flowing cells has been difficult because conventional frame-sequential acquisition of MIR-ON and MIR-OFF images is highly susceptible to motion-induced subtraction artifacts. Here we demonstrate MIP-IFC, a label-free imaging flow cytometry platform based on single-shot nanosecond-dual-pulse MIP (SNAP-MIP) microscopy. SNAP-MIP encodes the MIR-ON and MIR-OFF states into separate holographic channels within a single camera exposure, reducing their temporal separation to 20 ns. This single-shot acquisition suppresses motion artifacts and increases the allowable sample velocity for artifact-free MIP imaging by five orders of magnitude compared with conventional frame-sequential MIP imaging. Leveraging this capability, MIP-IFC acquired chemical images at 500 frames per second and achieved a cellular event rate up to ~70 events s^-1. We demonstrate quantitative chemical discrimination of flowing microbeads and apply MIP-IFC to single-cell profiling of oleic-acid-induced lipid accumulation, adipocyte differentiation, and confluence-dependent cellular heterogeneity. These results establish MIP-IFC as a high-throughput, quantitative, label-free chemical imaging platform for single-cell phenotyping under flow.

physics.optics↗

Label-free mid-infrared photothermal microscopy revisits intracellular thermal dynamics: what do fluorescent nanothermometers measure?

Fluorescent nanothermometry has revealed pronounced intracellular temperature heterogeneity, establishing the field of single-cell thermal biology. However, these observations have sparked a controversy known as the "10^5 gap issue", because heat conduction calculations in aqueous environments predict that such large temperature distributions cannot be sustained within cells. Here, we address this issue using label-free mid-infrared photothermal microscopy. This technique quantifies heat-induced temperature changes under local thermal equilibrium (LTE), in accordance with the conventional thermodynamic and statistical-mechanical definition of temperature, by detecting refractive index variations. From transient thermal decay measurements, we determined that intracellular thermal diffusivity corresponds to 93-94% that of water. This result indicates that intracellular heat conduction is essentially water-like and rules out the hypothesis that anomalously slow intracellular heat conduction underlies the 10^5 gap discrepancy. We then directly compared fluorescent nanothermometry with our label-free thermometry. Under seconds-long heating, the label-free method exhibited a rapid temperature response consistent with water-like heat conduction. In contrast, fluorescent nanothermometers showed not only a similarly fast response but also an additional slow variation that was absent in the label-free readout. This slow component cannot be explained by temperature changes defined under LTE, but instead likely reflects slower intracellular processes not governed by conductive heat transfer. These results suggest that the "10^5 gap issue" stems from comparing two fundamentally distinct physical quantities: the LTE-defined temperature and a slowly-varying, long-lived non-conductive signal detected by fluorescent nanothermometers.

physics.bio-ph↗

Video-rate volumetric chemical imaging via mid-infrared photothermal optical diffraction tomography

Label-free vibrational microscopy provides chemically specific access to cellular structure, yet quantitative volumetric chemical dynamics in living cells remain largely inaccessible, particularly on subsecond timescales relevant to intracellular transport and structural reorganization. This limitation arises because most high-speed vibrational techniques rely on raster scanning, which constrains volumetric throughput to approximately one volume per second (vps). Although mid-infrared photothermal (MIP) imaging offers a pathway toward spatially parallel chemical detection, existing implementations have remained far below video-rate volumetric operation, reflecting a fundamental trade-off between imaging speed and signal-to-noise ratio. Here, we overcome this trade-off in MIP tomography and realize video-rate volumetric chemical imaging using mid-infrared photothermal optical diffraction tomography (MIP-ODT), achieving high photothermal sensitivity while maintaining quantitative measurement fidelity. High per-angle detectability supports volumetric reconstruction without temporal averaging, yielding a signal-to-noise ratio exceeding 70 under video-rate acquisition conditions. Consequently, volumetric imaging at 19.2 vps is achieved, representing a nearly 400-fold improvement over prior implementations. Using this capability, we performed video-rate three-dimensional tracking of lipid droplets in living cells and quantified anomalous diffusion from full volumetric trajectories, revealing heterogeneous intracellular transport behaviors that are obscured in two-dimensional measurements. We further demonstrate high-speed hyperspectral volumetric chemical imaging across a 300 cm-1 spectral window within 1 s through rapid MIR wavenumber sweeping, paving the way for real-time three-dimensional organelle-specific chemical phenotyping.

physics.optics↗

Bidirectional quantitative scattering microscopy

Quantitative phase microscopy (QPM) and interferometric scattering (iSCAT) microscopy are powerful label-free imaging techniques and are widely used for biomedical applications. Each method, however, possesses distinct limitations: QPM, which measures forward scattering (FS), excels at imaging microscale structures but struggles with rapidly moving nanoscale objects, while iSCAT, based on backward scattering (BS), is highly sensitive to nanoscale dynamics but lacks the ability to image microscale structures comprehensively. Here, we introduce bidirectional quantitative scattering microscopy (BiQSM), an innovative approach that integrates FS and BS detection using off-axis digital holography with bidirectional illumination and spatial-frequency multiplexing. BiQSM achieves spatiotemporal consistency and a dynamic range 14 times wider than QPM, enabling simultaneous imaging of nanoscale and microscale cellular components. We demonstrate BiQSM's ability to reveal spatiotemporal behaviors of intracellular structures, with FS-BS correlation analysis providing insights into proteins, lipids, and membranes. Time-lapse imaging of dying cells further highlights BiQSM's potential as a label-free tool for monitoring cellular vital states through structural and motion-related changes. By bridging the strengths of QPM and iSCAT, BiQSM advances quantitative cellular imaging and opens new avenues for studying dynamic biological processes.

physics.optics↗

Ludwig-Soret microscopy with vibrational photothermal effect

Vibrational microscopy provides label-free, bond-selective chemical contrast by detecting molecular vibrations, making it invaluable for biomedical research. While conventional methods rely on the direct detection of Raman scattering or infrared absorption, recently developed vibrational photothermal (ViP) microscopy achieves chemical contrast indirectly through refractive index (RI) changes. This indirect approach enables unique imaging capabilities beyond traditional chemical imaging. Here, we introduce a novel application of ViP microscopy: label-free intracellular thermophoretic (Soret) imaging, which visualizes biomolecular transport driven by temperature gradients. ViP-induced Soret (ViPS) imaging leverages a steady-state temperature distribution generated by optical heating through vibrational photothermal effect, combined with time-resolved RI imaging via optical diffraction tomography (ODT). Using ViPS imaging, we measured thermophoretic behavior in living COS7 cells, determining intracellular diffusion and Soret coefficients. Notably, we observed a reversed direction of molecular transport (negative Soret effect) in the cytoplasm compared to the nucleus, possibly driven by thermophoresis-induced diffusiophoresis. Furthermore, time-lapse imaging under CO2-depleted conditions revealed a remarkable reduction in thermophoretic activity, suggesting glass formation during the dying process, likely due to polymer aggregation. ViPS imaging represents a new frontier in intracellular thermophoretic studies, expanding the capabilities of vibrational microscopy.

physics.optics↗

Phase retrieval via Zernike phase contrast microscopy with an untrained neural network

Zernike's phase contrast microscopy (PCM) is among the most widely used techniques for observing phase objects, but it lacks quantitative nature, as it cannot directly provide phase information. Current methods for computationally extracting phase distributions from PCM images, however, rely heavily on empirical regularization parameter tuning. In this paper we extend an existing approach by employing an untrained neural network as an image prior, removing the need for manual regularization. We quantitatively demonstrate improved accuracy and robustness in phase retrieval compared to existing methods, using numerical and experimental PCM images. Our results confirm the feasibility of applying deep priors for phase retrieval in incoherent illumination setups.

physics.optics↗

Mid-infrared wide-field nanoscopy

Mid-infrared (MIR) spectroscopy is widely recognized as a powerful, non-distractive method for chemical analysis. However, its utility is constrained by a micrometer-scale spatial resolution imposed by the long-wavelength MIR diffraction limit. This limitation has been recently overcome by MIR photothermal (MIP) imaging, which detects photothermal effects induced in the vicinity of MIR absorbers using a visible-light microscope. Despite its promise, the full potential of its spatial resolving power has not been realized. Here, we present an optimal implementation of wide-field MIP imaging to achieve high spatial resolution. This is accomplished by employing single-objective synthetic-aperture quantitative phase imaging (SOSA-QPI) with synchronized sub-nanosecond MIR and visible light sources, effectively suppressing the resolution-degradation effect caused by photothermal heat diffusion. We demonstrate far-field MIR spectroscopic imaging with a spatial resolution limited by the visible diffraction, down to 125 nm, in the MIR region of 3.12-3.85 um (2,600-3,200 cm-1). This technique, through the use of a shorter visible wavelength and/or a higher objective numerical aperture, holds the potential to achieve a spatial resolution of less than 100 nm, thus paving the way for MIR wide-field nanoscopy.

physics.optics↗

Quantitative phase retrieval for Zernike phase-contrast microscopy

We present a single-image numerical phase retrieval method for Zernike phase-contrast microscopy (ZPM) that addresses halo and shade-off artifacts, as well as the weak phase condition, without requiring hardware modifications. By employing a rigorous physical model of ZPM and a gradient descent algorithm for its inversion, we achieve quantitative ZPM imaging. Our approach is experimentally validated using biological cells and its quantitative nature is confirmed through comparisons with digital holography observations.

physics.optics↗

Mid-infrared photothermal single-live-cell imaging beyond video rate

Advancement in mid-infrared (MIR) technology has led to promising biomedical applications of MIR spectroscopy, such as liquid biopsy or breath diagnosis. On the contrary, MIR microscopy has been rarely used for live biological samples in an aqueous environment due to the lack of spatial resolution and the large water absorption background. Recently, mid-infrared photothermal (MIP) imaging has proven to be applicable to 2D and 3D single-cell imaging with high spatial resolution inherited from visible light. However, the maximum measurement rate has been limited to several frames/s, limiting its range of use. Here, we develop a significantly-improved wide-field MIP quantitative phase microscope with two orders-of-magnitude higher signal-to-noise ratio than previous MIP imaging techniques and demonstrate single-live-cell imaging beyond video rate. We first derive optimal system design by numerically simulating thermal conduction following the photothermal effect. Then, we develop the designed system with a homemade nanosecond MIR optical parametric oscillator and a high full-well-capacity image sensor. Our high-speed and high-spatial-resolution MIR microscope has great potential to become a new tool for life science, in particular for single-live-cell analysis.

physics.optics↗

Adaptive dynamic range shift (ADRIFT) quantitative phase imaging

Quantitative phase imaging (QPI) is often used for label-free single cell analysis with its high-contrast images of optical phase delay (OPD) map. Contrary to other imaging methods, sensitivity improvement has not been intensively explored because conventional QPI is sensitive enough to see surface roughness of a substrate which anyway restricts the measurable minimum OPD. However, emerging QPI techniques which utilize, for example, differential image analysis of consecutive temporal frames, such as mid-infrared photothermal QPI, mitigate the minimum OPD limit by decoupling the static OPD contribution and allow to measure much smaller OPD. Here, we propose and demonstrate super-sensitive QPI with expanded dynamic range. It is enabled by adaptive dynamic range shift with combination of wavefront shaping and dark-field QPI techniques. As a proof-of-concept demonstration, we show dynamic range expansion (sensitivity improvement) of QPI by a factor of 6.6 and its utility for improving sensitivity of mid-infrared photothermal QPI. This technique can also be applied for wide-field scattering imaging of dynamically changing nanoscale objects inside and outside a biological cell without losing global cellular morphological image information.

physics.optics↗

Label-free biochemical quantitative phase imaging with mid-infrared photothermal effect

Label-free optical imaging is valuable in biology and medicine with its non-destructive property and reduced optical and chemical damages. Quantitative phase (QPI) and molecular vibrational imaging (MVI) are the two most successful label-free methods, providing morphology and biochemistry, respectively, that have pioneered numerous applications along their independent technological maturity over the past few decades. However, the distinct label-free contrasts are inherently complementary and difficult to integrate due to the use of different light-matter interactions. Here, we present a unified imaging scheme that realizes simultaneous and in-situ acquisition of MV-fingerprint contrasts of single cells in the framework of QPI utilizing the mid-infrared photothermal effect. The fully label-free and robust integration of subcellular morphology and biochemistry would have important implications, especially for studying complex and fragile biological phenomena such as drug delivery, cellular diseases and stem cell development, where long-time observation of unperturbed cells are needed under low phototoxicity.

physics.bio-ph↗

Quantitative phase imaging with molecular vibrational sensitivity

Quantitative phase imaging (QPI) quantifies the sample-specific optical-phase-delay enabling objective studies of optically-transparent specimens such as biological samples, but lacks chemical sensitivity limiting its application to morphology-based diagnosis. We present wide-field molecular-vibrational microscopy realized in the framework of QPI utilizing mid-infrared photothermal effect. Our technique provides mid-infrared spectroscopic performance comparable to that of a conventional infrared spectrometer in the molecular fingerprint region of 1,450 - 1,600 cm-1 and realizes wide-field molecular imaging of silica-polystyrene beads mixture over 100 μm x 100 μm area at 1 frame per second with the spatial resolution of 430 nm and 2 - 3 orders of magnitude lower fluence of ~10 pJ/μm2 compared to other high-speed label-free molecular imaging methods, reducing photodamages to the sample. With a high-energy mid-infrared pulse source, our technique could enable high-speed, label-free, simultaneous and in-situ acquisition of quantitative morphology and molecular-vibrational contrast, providing new insights for studies of optically-transparent complex dynamics.

physics.optics↗

Molecular contrast on phase-contrast microscope

An optical microscope enables image-based findings and diagnosis on microscopic targets, which is indispensable in many scientific, industrial and medical settings. Majority of microscope users are accustomed to standard benchtop microscopes, but it fails to give molecular contrast of the specimen which otherwise requires expensive specialized instruments to measure, accompanied by chemical or optical damages to the sample and/or slow imaging speed. Here, we report on a simple optical instrument, comprising of a semiconductor amplitude-modulated mid-infrared quantum cascade laser, that is attached to a standard microscope to deliver the additional molecular contrast of the specimen on top of its conventional microscopic image. We attach this instrument, termed molecular-contrast unit, to a standard phase-contrast microscope, and demonstrate high-speed label-free molecular-contrast phase-contrast imaging of biological cells under low-power optical illumination. Our simple molecular-contrast unit can empower existing standard microscopes of various users, by delivering a convenient accessibility to the molecular world.

physics.optics↗