arXiv ScienceSearch

arXiv subjects

Ke Zou

Publications and source records attributed to Ke Zou.

At least 19 recordsLinked to original sources

Hallucination Detection and Correction in Medical VLMs via Counter-Evidence Verification

Vision-Language models (VLMs) reliability in medical diagnosis is challenged by trust-undermining hallucinations. Existing hallucination detection approaches mainly focus on identifying factual inconsistencies between generated text and reference data. While some studies analyze where models attend in images, they seldom verify whether such attention truly reflects the visual evidence supporting the generated text. To address this gap, we propose Co}unter-Evidence Verification (CoEV), a training-free plug-and-play framework that detects and corrects hallucinations through evidence-based factual consistency verification. CoEV performs bidirectional verification between textual assertions and visual evidence, testing whether each statement is supported by its corresponding evidence region, and assigns each statement into a four-quadrant diagnostic map capturing combinations of text factuality and visual grounding. CoEV detects hallucinated content and serves as a post hoc refinement tool, correcting hallucinations without retraining. Extensive experiments on four medical datasets show that CoEV combats hallucinations in VLMs.For hallucination detection, CoEV consistently outperforms existing methods, improving average PR-AUC and ROC-AUC by 3.0% and 3.9% absolute points respectively, with notable gains of up to 18.5% in specific VQA scenarios. For hallucination correction, it improves Micro-F1 by up to 12.5%, reduces hallucination rates by over 11.9% on medical report generation, and also boosts medical VQA accuracy. These results show that CoEV enables reliable detection and correction of hallucinations, providing clinicians with dependable, evidence-based cues for diagnosis. Code will be released upon acceptance.

cs.CV

Enhancing Medical Visual Grounding via Knowledge-guided Spatial Prompts

Medical Visual Grounding (MVG) aims to identify diagnostically relevant phrases from free-text radiology reports and localize their corresponding regions in medical images, providing interpretable visual evidence to support clinical decision-making. Although recent Vision-Language Models (VLMs) exhibit promising multimodal reasoning ability, their grounding remains insufficient spatial precision, largely due to a lack of explicit localization priors when relying solely on latent embeddings. In this work, we analyze this limitation from an attention perspective and propose KnowMVG, a Knowledge-prior and global-local attention enhancement framework for MVG in VLMs that explicitly strengthens spatial awareness during decoding. Specifically, we present a knowledge-enhanced prompting strategy that encodes phrase related medical knowledge into compact embeddings, together with a global-local attention that jointly leverages coarse global information and refined local cues to guide precise region localization. localization. This design bridges high-level semantic understanding and fine-grained visual perception without introducing extra textual reasoning overhead. Extensive experiments on four MVG benchmarks demonstrate that our KnowMVG consistently outperforms existing approaches, achieving gains of 3.0% in AP50 and 2.6% in mIoU over prior state-of-the-art methods. Qualitative and ablation studies further validate the effectiveness of each component.

cs.CV

Direct Fabrication of a Superconducting Two-Dimensional Electron Gas on KTaO3(111) via Mg-Induced Surface Reduction

Two-dimensional electron gases (2DEGs) at the surfaces of KTaO3 have become an exciting platform for exploring strong spin-orbit coupling, Rashba physics, and low-carrier-density superconductivity. Yet, a large fraction of reported KTaO3-based 2DEGs has been realized through chemically complex overlayers that both generate carriers and can obscure the native electronic structure, making spectroscopic access to the underlying 2DEG challenging. Here, we demonstrate a simple and direct method to generate a superconducting 2DEG on KTaO3(111) using Mg-induced surface reduction in molecular-beam epitaxy (MBE). Mg has an extremely low sticking coefficient at elevated temperatures, enabling the formation of an ultrathin (less than 1-2 monolayers) MgO layer that is transparent to soft x-ray photoemission spectroscopy (XPS) and angle-resolved photoemission spectroscopy (ARPES). This allows direct measurement of the surface chemistry and low-energy electronic structure of the pristine reduced surface without the need for a several-nanometer-thick capping layer. XPS shows clear reduction of Ta5+ to lower oxidation states, while ARPES reveals a parabolic Ta 5d conduction band with an approximately 150 meV bandwidth and additional subband features arising from quantum confinement. Transport measurements confirm a superconducting transition below 0.7 K. Together, these results demonstrate a chemically straightforward and controllable pathway for fabricating spectroscopically accessible superconducting 2DEGs on KTaO3(111), and provide a powerful new platform for investigating the mechanisms underlying orientation-dependent superconductivity in KTaO3-based oxide interfaces.

cond-mat.supr-con

Percolative Pathway to Stripe Order in KTaO3-Based Superconductivity

The sensitivity of low dimensional superconductors to fluctuations gives rise to emergent behaviors beyond the conventional Bardeen Cooper Schrieffer framework. Anisotropy is one such manifestation, often linked to spatially modulated electronic states and unconventional pairing mechanisms. Pronounced in plane anisotropy recently reported at KTaO3 based oxide interfaces points to the emergence of a stripe order in superconducting phase, yet its microscopic origin and formation pathway remain unresolved. Here, we show that controlled interfacial disorder in MgO/KTaO3(111) heterostructures drives a percolative evolution from localized Cooper-pair islands to superconducting puddles and eventually to stripes. The extracted stripe width matches the spin precession length, suggesting a self organized modulation governed by spin orbit coupling and lattice-symmetry breaking. These findings identify disorder as both a tuning parameter and a diagnostic probe for emergent superconductivity in two dimensional quantum materials.

cond-mat.supr-con

LMOD+: A Comprehensive Multimodal Dataset and Benchmark for Developing and Evaluating Multimodal Large Language Models in Ophthalmology

Vision-threatening eye diseases pose a major global health burden, with timely diagnosis limited by workforce shortages and restricted access to specialized care. While multimodal large language models (MLLMs) show promise for medical image interpretation, advancing MLLMs for ophthalmology is hindered by the lack of comprehensive benchmark datasets suitable for evaluating generative models. We present a large-scale multimodal ophthalmology benchmark comprising 32,633 instances with multi-granular annotations across 12 common ophthalmic conditions and 5 imaging modalities. The dataset integrates imaging, anatomical structures, demographics, and free-text annotations, supporting anatomical structure recognition, disease screening, disease staging, and demographic prediction for bias evaluation. This work extends our preliminary LMOD benchmark with three major enhancements: (1) nearly 50% dataset expansion with substantial enlargement of color fundus photography; (2) broadened task coverage including binary disease diagnosis, multi-class diagnosis, severity classification with international grading standards, and demographic prediction; and (3) systematic evaluation of 24 state-of-the-art MLLMs. Our evaluations reveal both promise and limitations. Top-performing models achieved ~58% accuracy in disease screening under zero-shot settings, and performance remained suboptimal for challenging tasks like disease staging. We will publicly release the dataset, curation pipeline, and leaderboard to potentially advance ophthalmic AI applications and reduce the global burden of vision-threatening diseases.

cs.CV

Layer controlled orbital selective Mott transition in monolayer nickelate

Dimensionality and electronic correlations are crucial elements of many quantum material properties. An example is the change of the electronic structure accompanied by the loss of quasiparticles when a metal is reduced from three dimensions to a lower dimension, where the Coulomb interaction between carriers becomes poorly screened. Here, using angle-resolved photoemission spectroscopy (ARPES), we report an orbital-selective decoherence of spectral density in the perovskite nickelate LaNiO3 towards the monolayer limit. The spectral weight of the dz2 band vanishes much faster than that of the dx2-y2 band as the thickness of the LaNiO3 layer is decreased to a single unit cell, indicating a stronger correlation effect for the former upon dimensional confinement. Dynamical mean-field theory (DMFT) calculations show an orbital-selective Mott transition largely due to the localization of dz2 electrons along the c axis in the monolayer limit. This orbital-selective correlation effect underpins many macroscopic properties of nickelates, such as metal-to-insulator transition and superconductivity, where most theories are built upon a dx2-y2-dz2 two-band model.

cond-mat.str-el

Generalist versus Specialist Vision Foundation Models for Ocular Disease and Oculomics

Medical foundation models, pre-trained with large-scale clinical data, demonstrate strong performance in diverse clinically relevant applications. RETFound, trained on nearly one million retinal images, exemplifies this approach in applications with retinal images. However, the emergence of increasingly powerful and multifold larger generalist foundation models such as DINOv2 and DINOv3 raises the question of whether domain-specific pre-training remains essential, and if so, what gap persists. To investigate this, we systematically evaluated the adaptability of DINOv2 and DINOv3 in retinal image applications, compared to two specialist RETFound models, RETFound-MAE and RETFound-DINOv2. We assessed performance on ocular disease detection and systemic disease prediction using two adaptation strategies: fine-tuning and linear probing. Data efficiency and adaptation efficiency were further analysed to characterise trade-offs between predictive performance and computational cost. Our results show that although scaling generalist models yields strong adaptability across diverse tasks, RETFound-DINOv2 consistently outperforms these generalist foundation models in ocular-disease detection and oculomics tasks, demonstrating stronger generalisability and data efficiency. These findings suggest that specialist retinal foundation models remain the most effective choice for clinical applications, while the narrowing gap with generalist foundation models suggests that continued data and model scaling can deliver domain-relevant gains and position them as strong foundations for future medical foundation models.

eess.IV

FusionFM: Fusing Eye-specific Foundational Models for Optimized Ophthalmic Diagnosis

Foundation models (FMs) have shown great promise in medical image analysis by improving generalization across diverse downstream tasks. In ophthalmology, several FMs have recently emerged, but there is still no clear answer to fundamental questions: Which FM performs the best? Are they equally good across different tasks? What if we combine all FMs together? To our knowledge, this is the first study to systematically evaluate both single and fused ophthalmic FMs. To address these questions, we propose FusionFM, a comprehensive evaluation suite, along with two fusion approaches to integrate different ophthalmic FMs. Our framework covers both ophthalmic disease detection (glaucoma, diabetic retinopathy, and age-related macular degeneration) and systemic disease prediction (diabetes and hypertension) based on retinal imaging. We benchmarked four state-of-the-art FMs (RETFound, VisionFM, RetiZero, and DINORET) using standardized datasets from multiple countries and evaluated their performance using AUC and F1 metrics. Our results show that DINORET and RetiZero achieve superior performance in both ophthalmic and systemic disease tasks, with RetiZero exhibiting stronger generalization on external datasets. Regarding fusion strategies, the Gating-based approach provides modest improvements in predicting glaucoma, AMD, and hypertension. Despite these advances, predicting systemic diseases, especially hypertension in external cohort remains challenging. These findings provide an evidence-based evaluation of ophthalmic FMs, highlight the benefits of model fusion, and point to strategies for enhancing their clinical applicability.

cs.CV

EH-Benchmark Ophthalmic Hallucination Benchmark and Agent-Driven Top-Down Traceable Reasoning Workflow

Medical Large Language Models (MLLMs) play a crucial role in ophthalmic diagnosis, holding significant potential to address vision-threatening diseases. However, their accuracy is constrained by hallucinations stemming from limited ophthalmic knowledge, insufficient visual localization and reasoning capabilities, and a scarcity of multimodal ophthalmic data, which collectively impede precise lesion detection and disease diagnosis. Furthermore, existing medical benchmarks fail to effectively evaluate various types of hallucinations or provide actionable solutions to mitigate them. To address the above challenges, we introduce EH-Benchmark, a novel ophthalmology benchmark designed to evaluate hallucinations in MLLMs. We categorize MLLMs' hallucinations based on specific tasks and error types into two primary classes: Visual Understanding and Logical Composition, each comprising multiple subclasses. Given that MLLMs predominantly rely on language-based reasoning rather than visual processing, we propose an agent-centric, three-phase framework, including the Knowledge-Level Retrieval stage, the Task-Level Case Studies stage, and the Result-Level Validation stage. Experimental results show that our multi-agent framework significantly mitigates both types of hallucinations, enhancing accuracy, interpretability, and reliability. Our project is available at https://github.com/ppxy1/EH-Benchmark.

cs.CL

BEnchmarking LLMs for Ophthalmology (BELO) for Ophthalmological Knowledge and Reasoning

Current benchmarks evaluating large language models (LLMs) in ophthalmology are limited in scope and disproportionately prioritise accuracy. We introduce BELO (BEnchmarking LLMs for Ophthalmology), a standardized and comprehensive evaluation benchmark developed through multiple rounds of expert checking by 13 ophthalmologists. BELO assesses ophthalmology-related clinical accuracy and reasoning quality. Using keyword matching and a fine-tuned PubMedBERT model, we curated ophthalmology-specific multiple-choice-questions (MCQs) from diverse medical datasets (BCSC, MedMCQA, MedQA, BioASQ, and PubMedQA). The dataset underwent multiple rounds of expert checking. Duplicate and substandard questions were systematically removed. Ten ophthalmologists refined the explanations of each MCQ's correct answer. This was further adjudicated by three senior ophthalmologists. To illustrate BELO's utility, we evaluated six LLMs (OpenAI o1, o3-mini, GPT-4o, DeepSeek-R1, Llama-3-8B, and Gemini 1.5 Pro) using accuracy, macro-F1, and five text-generation metrics (ROUGE-L, BERTScore, BARTScore, METEOR, and AlignScore). In a further evaluation involving human experts, two ophthalmologists qualitatively reviewed 50 randomly selected outputs for accuracy, comprehensiveness, and completeness. BELO consists of 900 high-quality, expert-reviewed questions aggregated from five sources: BCSC (260), BioASQ (10), MedMCQA (572), MedQA (40), and PubMedQA (18). A public leaderboard has been established to promote transparent evaluation and reporting. Importantly, the BELO dataset will remain a hold-out, evaluation-only benchmark to ensure fair and reproducible comparisons of future models.

cs.CL

Clinician-Friendly Foundation Models for Ophthalmic Image Diagnostics without Fine-Tuning or Technical Barriers

Artificial intelligence (AI) shows remarkable potential in medical imaging diagnostics, yet most current models require retraining when applied across different clinical settings, limiting their scalability. We developed GlobeReady, a deployment-oriented platform powered by the RetiGlobe foun- dation model and local feature augmentation. RetiGlobe was pretrained in two stages: 1) self-supervised learning using DINOv2 on 38 million synthetic ophthalmic images, and 2) contrastive learning using CLIP on 475,845 real image-text pairs spanning diverse ethnicities, imaging devices, and geographic regions worldwide. We evaluate GlobeReady on 488,448 ophthalmic images, including color fundus photographs (CFPs) and optical coherence tomography scans, from multi-centres in China, Singapore, Vietnam and the UK. Prospective testing included usability assessment with 31 ophthalmologists. Exploratory analyses evaluated domain generalisability, Bayesian uncertainty quantification, out-of-distribution (OOD) detection, and feature-based case retrieval.

cs.CV

Benchmarking Next-Generation Reasoning-Focused Large Language Models in Ophthalmology: A Head-to-Head Evaluation on 5,888 Items

Recent advances in reasoning-focused large language models (LLMs) mark a shift from general LLMs toward models designed for complex decision-making, a crucial aspect in medicine. However, their performance in specialized domains like ophthalmology remains underexplored. This study comprehensively evaluated and compared the accuracy and reasoning capabilities of four newly developed reasoning-focused LLMs, namely DeepSeek-R1, OpenAI o1, o3-mini, and Gemini 2.0 Flash-Thinking. Each model was assessed using 5,888 multiple-choice ophthalmology exam questions from the MedMCQA dataset in zero-shot setting. Quantitative evaluation included accuracy, Macro-F1, and five text-generation metrics (ROUGE-L, METEOR, BERTScore, BARTScore, and AlignScore), computed against ground-truth reasonings. Average inference time was recorded for a subset of 100 randomly selected questions. Additionally, two board-certified ophthalmologists qualitatively assessed clarity, completeness, and reasoning structure of responses to differential diagnosis questions.O1 (0.902) and DeepSeek-R1 (0.888) achieved the highest accuracy, with o1 also leading in Macro-F1 (0.900). The performance of models across the text-generation metrics varied: O3-mini excelled in ROUGE-L (0.151), o1 in METEOR (0.232), DeepSeek-R1 and o3-mini tied for BERTScore (0.673), DeepSeek-R1 (-4.105) and Gemini 2.0 Flash-Thinking (-4.127) performed best in BARTScore, while o3-mini (0.181) and o1 (0.176) led AlignScore. Inference time across the models varied, with DeepSeek-R1 being slowest (40.4 seconds) and Gemini 2.0 Flash-Thinking fastest (6.7 seconds). Qualitative evaluation revealed that DeepSeek-R1 and Gemini 2.0 Flash-Thinking tended to provide detailed and comprehensive intermediate reasoning, whereas o1 and o3-mini displayed concise and summarized justifications.

cs.CL

UniVRSE: Unified Vision-conditioned Response Semantic Entropy for Hallucination Detection in Medical Vision-Language Models

Vision-language models (VLMs) have great potential for medical image understanding, particularly in Visual Report Generation (VRG) and Visual Question Answering (VQA), but they may generate hallucinated responses that contradict visual evidence, limiting clinical deployment. Although uncertainty-based hallucination detection methods are intuitive and effective, they are limited in medical VLMs. Specifically, Semantic Entropy (SE), effective in text-only LLMs, becomes less reliable in medical VLMs due to their overconfidence from strong language priors. To address this challenge, we propose UniVRSE, a Unified Vision-conditioned Response Semantic Entropy framework for hallucination detection in medical VLMs. UniVRSE strengthens visual guidance during uncertainty estimation by contrasting the semantic predictive distributions derived from an original image-text pair and a visually distorted counterpart, with higher entropy indicating hallucination risk. For VQA, UniVRSE works on the image-question pair, while for VRG, it decomposes the report into claims, generates verification questions, and applies vision-conditioned entropy estimation at the claim level. To evaluate hallucination detection, we propose a unified pipeline that generates responses on medical datasets and derives hallucination labels via factual consistency assessment. However, current evaluation methods rely on subjective criteria or modality-specific rules. To improve reliability, we introduce Alignment Ratio of Atomic Facts (ALFA), a novel method that quantifies fine-grained factual consistency. ALFA-derived labels provide ground truth for robust benchmarking. Experiments on six medical VQA/VRG datasets and three VLMs show UniVRSE significantly outperforms existing methods with strong cross-modal generalization.

cs.CV

Is an Ultra Large Natural Image-Based Foundation Model Superior to a Retina-Specific Model for Detecting Ocular and Systemic Diseases?

The advent of foundation models (FMs) is transforming medical domain. In ophthalmology, RETFound, a retina-specific FM pre-trained sequentially on 1.4 million natural images and 1.6 million retinal images, has demonstrated high adaptability across clinical applications. Conversely, DINOv2, a general-purpose vision FM pre-trained on 142 million natural images, has shown promise in non-medical domains. However, its applicability to clinical tasks remains underexplored. To address this, we conducted head-to-head evaluations by fine-tuning RETFound and three DINOv2 models (large, base, small) for ocular disease detection and systemic disease prediction tasks, across eight standardized open-source ocular datasets, as well as the Moorfields AlzEye and the UK Biobank datasets. DINOv2-large model outperformed RETFound in detecting diabetic retinopathy (AUROC=0.850-0.952 vs 0.823-0.944, across three datasets, all P<=0.007) and multi-class eye diseases (AUROC=0.892 vs. 0.846, P<0.001). In glaucoma, DINOv2-base model outperformed RETFound (AUROC=0.958 vs 0.940, P<0.001). Conversely, RETFound achieved superior performance over all DINOv2 models in predicting heart failure, myocardial infarction, and ischaemic stroke (AUROC=0.732-0.796 vs 0.663-0.771, all P<0.001). These trends persisted even with 10% of the fine-tuning data. These findings showcase the distinct scenarios where general-purpose and domain-specific FMs excel, highlighting the importance of aligning FM selection with task-specific requirements to optimise clinical performance.

eess.IV

Are Traditional Deep Learning Model Approaches as Effective as a Retinal-Specific Foundation Model for Ocular and Systemic Disease Detection?

Background: RETFound, a self-supervised, retina-specific foundation model (FM), showed potential in downstream applications. However, its comparative performance with traditional deep learning (DL) models remains incompletely understood. This study aimed to evaluate RETFound against three ImageNet-pretrained supervised DL models (ResNet50, ViT-base, SwinV2) in detecting ocular and systemic diseases. Methods: We fine-tuned/trained RETFound and three DL models on full datasets, 50%, 20%, and fixed sample sizes (400, 200, 100 images, with half comprising disease cases; for each DR severity class, 100 and 50 cases were used. Fine-tuned models were tested internally using the SEED (53,090 images) and APTOS-2019 (3,672 images) datasets and externally validated on population-based (BES, CIEMS, SP2, UKBB) and open-source datasets (ODIR-5k, PAPILA, GAMMA, IDRiD, MESSIDOR-2). Model performance was compared using area under the receiver operating characteristic curve (AUC) and Z-tests with Bonferroni correction (P<0.05/3). Interpretation: Traditional DL models are mostly comparable to RETFound for ocular disease detection with large datasets. However, RETFound is superior in systemic disease detection with smaller datasets. These findings offer valuable insights into the respective merits and limitation of traditional models and FMs.

cs.CV

Can OpenAI o1 Reason Well in Ophthalmology? A 6,990-Question Head-to-Head Evaluation Study

Question: What is the performance and reasoning ability of OpenAI o1 compared to other large language models in addressing ophthalmology-specific questions? Findings: This study evaluated OpenAI o1 and five LLMs using 6,990 ophthalmological questions from MedMCQA. O1 achieved the highest accuracy (0.88) and macro-F1 score but ranked third in reasoning capabilities based on text-generation metrics. Across subtopics, o1 ranked first in ``Lens'' and ``Glaucoma'' but second to GPT-4o in ``Corneal and External Diseases'', ``Vitreous and Retina'' and ``Oculoplastic and Orbital Diseases''. Subgroup analyses showed o1 performed better on queries with longer ground truth explanations. Meaning: O1's reasoning enhancements may not fully extend to ophthalmology, underscoring the need for domain-specific refinements to optimize performance in specialized fields like ophthalmology.

cs.CL

Magnetic Ni-N-Ni Centers in N-substituted NiO

To explore how anion substitution modifies the existing magnetism in strongly correlated oxides, we investigate local electronic states and magnetic ordering in nickel oxide (NiO) induced by substituting oxygen (O) with nitrogen (N). Each N introduces an additional N 2p hole and modifies the magnetic moment of a neighboring nickel (Ni) cation site, as the exchange interaction between this hole and the Ni eg electrons exceeds the Ni-O-Ni superexchange interaction. This leads to the formation of Ni-N-Ni centers consisting of five spins, without perturbing the antiferromagnetic NiO lattice. These centers are studied using density functional theory and confirmed through high-resolution spectroscopy on N-substituted NiO thin films grown by molecular beam epitaxy. This type of magnetic design may enable future advances in quantum technologies based on strongly correlated materials, such as quantum sensors and spin-based qubits.

cond-mat.str-el

GEMeX: A Large-Scale, Groundable, and Explainable Medical VQA Benchmark for Chest X-ray Diagnosis

Medical Visual Question Answering (Med-VQA) combines computer vision and natural language processing to automatically answer clinical inquiries about medical images. However, current Med-VQA datasets exhibit two significant limitations: (1) they often lack visual and textual explanations for answers, hindering comprehension for patients and junior doctors; (2) they typically offer a narrow range of question formats, inadequately reflecting the diverse requirements in practical scenarios. These limitations pose significant challenges to the development of a reliable and user-friendly Med-VQA system. To address these challenges, we introduce a large-scale, Groundable, and Explainable Medical VQA benchmark for chest X-ray diagnosis (GEMeX), featuring several innovative components: (1) a multi-modal explainability mechanism that offers detailed visual and textual explanations for each question-answer pair, thereby enhancing answer comprehensibility; (2) four question types, open-ended, closed-ended, single-choice, and multiple-choice, to better reflect practical needs. With 151,025 images and 1,605,575 questions, GEMeX is the currently largest chest X-ray VQA dataset. Evaluation of 12 representative large vision language models (LVLMs) on GEMeX reveals suboptimal performance, underscoring the dataset's complexity. Meanwhile, we propose a strong model by fine-tuning an existing LVLM on the GEMeX training set. The substantial performance improvement showcases the dataset's effectiveness. The benchmark is available at https://www.med-vqa.com/GEMeX.

cs.CV