Is Deformable Image Registration Ready for Brain Metastasis Reirradiation Dose Accumulation? A Longitudinal MRI Benchmark of Registration Accuracy

Dose accumulation is increasingly important in adaptive radiation therapy and reirradiation, but its clinical validity depends on the performance of deformable image registration (DIR). Reirradiation of brain metastases (BMs) with stereotactic radiosurgery (SRS) provides a controlled but clinically meaningful DIR test case: intra-subject brain deformation is usually limited after rigid alignment, yet recurrent lesions can undergo substantial local shape and volume changes that rigid registration cannot capture and can affect dose accumulation. We benchmarked a wide range of learning-based and optimization-based DIR methods on 87 manually screened longitudinal contrast-enhanced T1-weighted MRI lesion pairs from an institutional BM SRS retreatment cohort. Learning-based methods pretrained on healthy-brain MRI were evaluated zero-shot and after instance-specific optimization (ISO) or tumor-proximity target-specific optimization (TSO). Registration was assessed using lesion overlap (Dice), surface distance metrics (HD95 and sASD), target-volume recovery, and runtime and memory. Pretrained learning-based methods showed variable zero-shot performance, while ISO/TSO improved all tested learning-based families. However, optimization-based methods remained the best-performing approach while maintaining reasonable runtime. These findings suggest that even state-of-the-art DIR methods do not yet provide sufficiently accurate and consistent registration for unmonitored use in brain metastasis reirradiation dose accumulation. Because accurate registration is a prerequisite for deformable dose accumulation, clinical application will require case-level quality control and direct assessment of how registration uncertainty affects downstream dose metrics.

eess.IV

The Right Prior for the Right Deformation: Rethinking Continuous Deformable Image Registration

Deformable image registration models implicitly encode deformation priors through their parametrization and optimization. In this work, we conduct a validation study on continuous registration methods to examine how these implicit priors affect performance across different registration tasks. Classic B-Spline transformations impose locality, smoothness, and scale through their control-point structure, whereas recent INR-based methods impose different priors through neural parameterization and optimization. We compare INR-Dense (IDIR), which directly models a dense displacement field using a SIREN-based INR; INR-BSCP (SINR), which predicts B-Spline control points with an INR; D-BSCP, which directly optimizes single-scale B-Spline control points; and MR-D-BSCP, which adds a multiresolution coarse-to-fine scheme. Experiments on inter-subject brain MR registration (OASIS) and intra-subject exhale-to-inhale lung CT registration (DIR-LAB 4DCT) reveal different behavior across deformation regimes. On OASIS, where deformations are moderate but locally complex, D-BSCP matches or slightly outperforms INR-BSCP, suggesting that the B-Spline parameterization accounts for much of INR-BSCP's effectiveness. On DIR-LAB 4DCT, where respiratory motion is larger and more coherent, single-scale B-Spline methods (D-BSCP and INR-BSCP) are less suitable, while INR-Dense and MR-D-BSCP are more effective. Across both tasks, MR-D-BSCP achieves the best performance among the tested continuous parameterizations. These findings highlight that registration accuracy depends strongly on matching the induced deformation prior to the target motion pattern, and support prior-deformation matching as a practical design principle for medical image registration. Our code will be available at https://github.com/HengjieLiu/RightPriorDIR.

cs.CV

4$\pi$ Planning for the Reduction of Predicted Hematologic Toxicity Risk in Cervical Cancer Radiotherapy

Purpose: In conventional coplanar radiotherapy for cervical cancer, nearby pelvic bones receive high radiation doses, increasing the risk of acute hematologic toxicity (HT). This study aims to estimate the HT risk reduction achievable with non-coplanar (4$\pi$) radiotherapy. Methods: We retrospectively analyzed 114 cervical cancer patients treated with coplanar volumetric modulated arc therapy (VMAT) between 2021 and 2023. Radiomic features from planning CTs were extracted and combined with clinical and dosimetric data to train predictive machine learning models. Patients were then replanned using integrated non-coplanar beam orientation and fluence map optimization (4$\pi$ planning). The top performing model was applied to these new plans to evaluate potential HT reduction. Results: Models combined radiomics, clinical, and dosimetric features achieved the highest predictive performance (AUC = 0.79). Feature importance analysis highlighted CT radiomic and dosimetric variables as the strongest predictors. Compared to VMAT, 4$\pi$ non-coplanar planning significantly reduced doses to the bone marrow (V10Gy, V20Gy, V30Gy, and V40Gy by 28%, 52%, 47%, and 33%, respectively) while significantly reducing dose to other pelvic organs at risk (OAR). When evaluated by the model, this improved dosimetry translated into a 23% reduction in predicted HT risk (risk ratio: 0.77; 95% CI: 0.75-0.79 and odds ratio: 0.68; 95% CI:0.65-0.71). Conclusions: Non-coplanar 4$\pi$ radiotherapy significantly lowers radiation doses to major pelvic bones during cervical cancer treatment without compromising target coverage or sparing of other OARs. Based on our predictive model, this superior dosimetry should translate to a marked reduction in acute hematologic toxicity.

physics.med-ph

Prediction of Radiotherapy-Induced Hematologic Toxicity in Cervical Cancer with Cohort-Aware Framework

Hematologic toxicity (HT) is a major dose-limiting complication of pelvic radiotherapy for cervical cancer. Although radiomic and dosiomic features improve HT prediction beyond dosimetric metrics, their performance is highly sensitive to contour variability, limiting generalizability. We developed a cohort-aware representation-learning framework to address this challenge. We retrospectively analyzed 152 cervical cancer patients treated with pelvic radiotherapy without concurrent chemotherapy. Patients were divided into two cohorts based on the operators performing pelvic bone segmentation. HT prediction models were developed using cohort-specific training, pooled training, statistical harmonization, and a cohort-aware neural network (CANN) that learns shared and cohort-specific representations with contrastive regularization. Performance was evaluated using cross-validation and an independent test set. Cohort-specific models achieved test AUCs of 0.77 and 0.71, outperforming a dosimetry-only model (AUC=0.58). Directly pooling cohorts reduced performance (test AUC=0.64). Statistical harmonization provided limited benefit, while adversarial and correlation-based alignment further degraded performance. CANN achieved the best balance between robustness and generalizability (test AUC=0.72), with ablation studies confirming the importance of cohort-specific representations and contrastive alignment. These results demonstrate that cohort-aware representation learning effectively mitigates contour variability and improves the generalizability of radiomic and dosiomic models for HT prediction.

physics.med-ph

Zero-shot Multi-Contrast Brain MRI Registration by Intensity Randomizing T1-weighted MRI (LUMIR25)

In this paper, we present our submission to the LUMIR25 task of Learn2Reg 2025, which ranked 1st overall on the test set. Extended from LUMIR24, this year's task focuses on zero-shot registration under domain shifts (e.g., high-field MRI, pathological brains, and various MRI contrasts), while the training data comprises only in-domain T1-weighted brain MRI. We start with a meticulous analysis of LUMIR24 winners to identify the main contributors to strong monomodal registration performance. We highlight the importance of registration-specific inductive biases, including multi-resolution pyramids, inverse and group consistency, topological preservation or diffeomorphism, and correlation-based correspondence establishment. To further generalize to diverse contrasts, we employ three simple but effective strategies: (i) a multimodal loss based on the modality-independent neighborhood descriptor (MIND), (ii) intensity randomization for unseen contrast augmentation, and (iii) lightweight instance-specific optimization (ISO) on feature encoders at inference time. On the validation set, the proposed approach substantially improves T1-T2 registration accuracy, demonstrating robust cross-contrast generalization without relying on explicit image synthesis. These results suggest a practical step toward a registration foundation model that can leverage a single training domain yet remain robust across domain shifts.

eess.IV

B-FIRE: Binning-Free Diffusion Implicit Neural Representation for Hyper-Accelerated Motion-Resolved MRI

Accelerated dynamic volumetric magnetic resonance imaging (4DMRI) is essential for applications relying on motion resolution. Existing 4DMRI produces acceptable artifacts of averaged breathing phases, which can blur and misrepresent instantaneous dynamic information. Recovery of such information requires a new paradigm to reconstruct extremely undersampled non-Cartesian k-space data. We propose B-FIRE, a binning-free diffusion implicit neural representation framework for hyper-accelerated MR reconstruction capable of reflecting instantaneous 3D abdominal anatomy. B-FIRE employs a CNN-INR encoder-decoder backbone optimized using diffusion with a comprehensive loss that enforces image-domain fidelity and frequency-aware constraints. Motion binned image pairs were used as training references, while inference was performed on binning-free undersampled data. Experiments were conducted on a T1-weighted StarVIBE liver MRI cohort, with accelerations ranging from 8 spokes per frame (RV8) to RV1. B-FIRE was compared against direct NuFFT, GRASP-CS, and an unrolled CNN method. Reconstruction fidelity, motion trajectory consistency, and inference latency were evaluated.

cs.CV

Spherical Radiomics -- A Novel Approach to Glioblastoma Radiogenomic Analysis of Heterogeneity

We develop and validate a novel spherical radiomics framework for predicting key molecular biomarkers using multiparametric MRI. Conventional Cartesian radiomics extract tumor features on orthogonal grids, which do not fully capture the tumor's radial growth patterns and can be insensitive to evolving molecular signatures. In this study, we analyzed GBM radiomic features on concentric 2D shells, which were then mapped onto 2D planes for radiomics analysis. Radiomic features were extracted using PyRadiomics from four different regions in GBM. Feature selection was performed using ANOVA F-statistics. Classification was conducted with multiple machine-learning models. Model interpretability was evaluated through SHAP analysis, clustering analysis, feature significance profiling, and comparison between radiomic patterns and underlying biological processes. Spherical radiomics consistently outperformed conventional 2D and 3D Cartesian radiomics across all prediction tasks. The best framework reached an AUC of 0.85 for MGMT, 0.80 for EGFR, 0.80 for PTEN, and 0.83 for survival prediction. GLCM-derived features were identified as the most informative predictors. Radial transition analysis using the Mann-Whitney U-test demonstrates that transition slopes between T1-weighted contrast-enhancing and T2/FLAIR hyperintense lesion regions, as well as between T2 intense lesion and a 2 cm peritumoral expansion region, are significantly associated with biomarker status. Furthermore, the observed radiomic changes along the radial direction closely reflected known biological characteristics. Radiomic features extracted on the spherical surfaces at varying radial distances to the GBM tumor centroid are better correlated with important tumor molecular markers and patient survival than the conventional Cartesian analysis.

physics.med-ph

Accelerated Patient-specific Non-Cartesian MRI Reconstruction using Implicit Neural Representations

The scanning time for a fully sampled MRI can be undesirably lengthy. Compressed sensing has been developed to minimize image artifacts in accelerated scans, but the required iterative reconstruction is computationally complex and difficult to generalize on new cases. Image-domain-based deep learning methods (e.g., convolutional neural networks) emerged as a faster alternative but face challenges in modeling continuous k-space, a problem amplified with non-Cartesian sampling commonly used in accelerated acquisition. In comparison, implicit neural representations can model continuous signals in the frequency domain and thus are compatible with arbitrary k-space sampling patterns. The current study develops a novel generative-adversarially trained implicit neural representations (k-GINR) for de novo undersampled non-Cartesian k-space reconstruction. k-GINR consists of two stages: 1) supervised training on an existing patient cohort; 2) self-supervised patient-specific optimization. In stage 1, the network is trained with the generative-adversarial network on diverse patients of the same anatomical region supervised by fully sampled acquisition. In stage 2, undersampled k-space data of individual patients is used to tailor the prior-embedded network for patient-specific optimization. The UCSF StarVIBE T1-weighted liver dataset was evaluated on the proposed framework. k-GINR is compared with an image-domain deep learning method, Deep Cascade CNN, and a compressed sensing method. k-GINR consistently outperformed the baselines with a larger performance advantage observed at very high accelerations (e.g., 20 times). k-GINR offers great value for direct non-Cartesian k-space reconstruction for new incoming patients across a wide range of accelerations liver anatomy.

eess.IV

Rapid Reconstruction of Extremely Accelerated Liver 4D MRI via Chained Iterative Refinement

Abstract Purpose: High-quality 4D MRI requires an impractically long scanning time for dense k-space signal acquisition covering all respiratory phases. Accelerated sparse sampling followed by reconstruction enhancement is desired but often results in degraded image quality and long reconstruction time. We hereby propose the chained iterative reconstruction network (CIRNet) for efficient sparse-sampling reconstruction while maintaining clinically deployable quality. Methods: CIRNet adopts the denoising diffusion probabilistic framework to condition the image reconstruction through a stochastic iterative denoising process. During training, a forward Markovian diffusion process is designed to gradually add Gaussian noise to the densely sampled ground truth (GT), while CIRNet is optimized to iteratively reverse the Markovian process from the forward outputs. At the inference stage, CIRNet performs the reverse process solely to recover signals from noise, conditioned upon the undersampled input. CIRNet processed the 4D data (3D+t) as temporal slices (2D+t). The proposed framework is evaluated on a data cohort consisting of 48 patients (12332 temporal slices) who underwent free-breathing liver 4D MRI. 3-, 6-, 10-, 20- and 30-times acceleration were examined with a retrospective random undersampling scheme. Compressed sensing (CS) reconstruction with a spatiotemporal constraint and a recently proposed deep network, Re-Con-GAN, are selected as baselines. Results: CIRNet consistently achieved superior performance compared to CS and Re-Con-GAN. The inference time of CIRNet, CS, and Re-Con-GAN are 11s, 120s, and 0.15s. Conclusion: A novel framework, CIRNet, is presented. CIRNet maintains useable image quality for acceleration up to 30 times, significantly reducing the burden of 4DMRI.

eess.IV

TomoGRAF: A Robust and Generalizable Reconstruction Network for Single-View Computed Tomography

Computed tomography (CT) provides high spatial resolution visualization of 3D structures for scientific and clinical applications. Traditional analytical/iterative CT reconstruction algorithms require hundreds of angular data samplings, a condition that may not be met in practice due to physical and mechanical limitations. Sparse view CT reconstruction has been proposed using constrained optimization and machine learning methods with varying success, less so for ultra-sparse view CT reconstruction with one to two views. Neural radiance field (NeRF) is a powerful tool for reconstructing and rendering 3D natural scenes from sparse views, but its direct application to 3D medical image reconstruction has been minimally successful due to the differences between optical and X-ray photon transportation. Here, we develop a novel TomoGRAF framework incorporating the unique X-ray transportation physics to reconstruct high-quality 3D volumes using ultra-sparse projections without prior. TomoGRAF captures the CT imaging geometry, simulates the X-ray casting and tracing process, and penalizes the difference between simulated and ground truth CT sub-volume during training. We evaluated the performance of TomoGRAF on an unseen dataset of distinct imaging characteristics from the training data and demonstrated a vast leap in performance compared with state-of-the-art deep learning and NeRF methods. TomoGRAF provides the first generalizable solution for image-guided radiotherapy and interventional radiology applications, where only one or a few X-ray views are available, but 3D volumetric information is desired.

eess.IV

Multi-Modality and Temporal Analysis of Cervical Cancer Treatment Response

Cervical cancer presents a significant global health challenge, necessitating advanced diagnostic and prognostic approaches for effective treatment. This paper investigates the potential of employing multi-modal medical imaging at various treatment stages to enhance cervical cancer treatment outcomes prediction. We show that among Gray Level Co-occurrence Matrix (GLCM) features, contrast emerges as the most effective texture feature regarding prediction accuracy. Integration of multi-modal imaging and texture analysis offers a promising avenue for personalized and targeted interventions, as well as more effective management of cervical cancer. Moreover, there is potential to reduce the number of time measurements and modalities in future cervical cancer treatment. This research contributes to advancing the field of precision diagnostics by leveraging the information embedded in noninvasive medical images, contributing to improving prognostication and optimizing therapeutic strategies for individuals diagnosed with cervical cancer.

physics.med-ph

Exploring Automated Contouring Across Institutional Boundaries: A Deep Learning Approach with Mouse Micro-CT Datasets

Image-guided mouse irradiation is essential to understand interventions involving radiation prior to human studies. Our objective is to employ Swin UNEt Transformers (Swin UNETR) to segment native micro-CT and contrast-enhanced micro-CT scans and benchmark the results against 3D no-new-Net (nnU-Net). Swin UNETR reformulates mouse organ segmentation as a sequence-to-sequence prediction task, using a hierarchical Swin Transformer encoder to extract features at 5 resolution levels, and connects to a Fully Convolutional Neural Network (FCNN)-based decoder via skip connections. The models were trained and evaluated on open datasets, with data separation based on individual mice. Further evaluation on an external mouse dataset acquired on a different micro-CT with lower kVp and higher imaging noise was also employed to assess model robustness and generalizability. Results indicate that Swin UNETR consistently outperforms nnU-Net and AIMOS in terms of average dice similarity coefficient (DSC) and Hausdorff distance (HD95p), except in two mice of intestine contouring. This superior performance is especially evident in the external dataset, confirming the model's robustness to variations in imaging conditions, including noise and quality, thereby positioning Swin UNETR as a highly generalizable and efficient tool for automated contouring in pre-clinical workflows.

physics.med-ph

Paired Conditional Generative Adversarial Network for Highly Accelerated Liver 4D MRI

Purpose: 4D MRI with high spatiotemporal resolution is desired for image-guided liver radiotherapy. Acquiring densely sampling k-space data is time-consuming. Accelerated acquisition with sparse samples is desirable but often causes degraded image quality or long reconstruction time. We propose the Reconstruct Paired Conditional Generative Adversarial Network (Re-Con-GAN) to shorten the 4D MRI reconstruction time while maintaining the reconstruction quality. Methods: Patients who underwent free-breathing liver 4D MRI were included in the study. Fully- and retrospectively under-sampled data at 3, 6 and 10 times (3x, 6x and 10x) were first reconstructed using the nuFFT algorithm. Re-Con-GAN then trained input and output in pairs. Three types of networks, ResNet9, UNet and reconstruction swin transformer, were explored as generators. PatchGAN was selected as the discriminator. Re-Con-GAN processed the data (3D+t) as temporal slices (2D+t). A total of 48 patients with 12332 temporal slices were split into training (37 patients with 10721 slices) and test (11 patients with 1611 slices). Results: Re-Con-GAN consistently achieved comparable/better PSNR, SSIM, and RMSE scores compared to CS/UNet models. The inference time of Re-Con-GAN, UNet and CS are 0.15s, 0.16s, and 120s. The GTV detection task showed that Re-Con-GAN and CS, compared to UNet, better improved the dice score (3x Re-Con-GAN 80.98%; 3x CS 80.74%; 3x UNet 79.88%) of unprocessed under-sampled images (3x 69.61%). Conclusion: A generative network with adversarial training is proposed with promising and efficient reconstruction results demonstrated on an in-house dataset. The rapid and qualitative reconstruction of 4D liver MR has the potential to facilitate online adaptive MR-guided radiotherapy for liver cancer.

eess.IV

Nodule detection and generation on chest X-rays: NODE21 Challenge

Pulmonary nodules may be an early manifestation of lung cancer, the leading cause of cancer-related deaths among both men and women. Numerous studies have established that deep learning methods can yield high-performance levels in the detection of lung nodules in chest X-rays. However, the lack of gold-standard public datasets slows down the progression of the research and prevents benchmarking of methods for this task. To address this, we organized a public research challenge, NODE21, aimed at the detection and generation of lung nodules in chest X-rays. While the detection track assesses state-of-the-art nodule detection systems, the generation track determines the utility of nodule generation algorithms to augment training data and hence improve the performance of the detection systems. This paper summarizes the results of the NODE21 challenge and performs extensive additional experiments to examine the impact of the synthetically generated nodule training images on the detection algorithm performance.

eess.IV

A Two-Step Framework for Multi-Material Decomposition of Dual Energy Computed Tomography from Projection Domain

Dual-energy computed tomography (DECT) utilizes separate X-ray energy spectra to improve multi-material decomposition (MMD) for various diagnostic applications. However accurate decomposing more than two types of material remains challenging using conventional methods. Deep learning (DL) methods have shown promise to improve the MMD performance, but typical approaches of conducing DL-MMD in the image domain fail to fully utilize projection information or under iterative setup are computationally inefficient in both training and prediction. In this work, we present a clinical-applicable MMD (>2) framework rFast-MMDNet, operating with raw projection data in non-recursive setup, for breast tissue differentiation. rFast-MMDNet is a two-stage algorithm, including stage-one SinoNet to perform dual energy projection decomposition on tissue sinograms and stage-two FBP-DenoiseNet to perform domain adaptation and image post-processing. rFast-MMDNet was tested on a 2022 DL-Spectral-Challenge breast phantom dataset. The two stages of rFast-MMDNet were evaluated separately and then compared with four noniterative reference methods including a direct inversion method (AA-MMD), an image domain DL method (ID-UNet), AA-MMD/ID-UNet + DenoiseNet and a sinogram domain DL method (Triple-CBCT). Our results show that models trained from information stored in DE transmission domain can yield high-fidelity decomposition of the adipose, calcification, and fibroglandular materials with averaged RMSE, MAE, negative PSNR, and SSIM of 0.004+/-~0, 0.001+/-~0, -45.027+/-~0.542, and 0.002+/-~0 benchmarking to the ground truth, respectively. Training of entire rFast-MMDNet on a 4xRTX A6000 GPU cluster took a day with inference time <1s. All DL methods generally led to more accurate MMD than AA-MMD. rFast-MMDNet outperformed Triple-CBCT, but both are superior to the image-domain based methods.

eess.IV

Learning Dynamic MRI Reconstruction with Convolutional Network Assisted Reconstruction Swin Transformer

Dynamic magnetic resonance imaging (DMRI) is an effective imaging tool for diagnosis tasks that require motion tracking of a certain anatomy. To speed up DMRI acquisition, k-space measurements are commonly undersampled along spatial or spatial-temporal domains. The difficulty of recovering useful information increases with increasing undersampling ratios. Compress sensing was invented for this purpose and has become the most popular method until deep learning (DL) based DMRI reconstruction methods emerged in the past decade. Nevertheless, existing DL networks are still limited in long-range sequential dependency understanding and computational efficiency and are not fully automated. Considering the success of Transformers positional embedding and "swin window" self-attention mechanism in the vision community, especially natural video understanding, we hereby propose a novel architecture named Reconstruction Swin Transformer (RST) for 4D MRI. RST inherits the backbone design of the Video Swin Transformer with a novel reconstruction head introduced to restore pixel-wise intensity. A convolution network called SADXNet is used for rapid initialization of 2D MR frames before RST learning to effectively reduce the model complexity, GPU hardware demand, and training time. Experimental results in the cardiac 4D MR dataset further substantiate the superiority of RST, achieving the lowest RMSE of 0.0286 +/- 0.0199 and 1 - SSIM of 0.0872 +/- 0.0783 on 9 times accelerated validation sequences.

eess.IV

An Efficient and Robust Method for Chest X-Ray Rib Suppression that Improves Pulmonary Abnormality Diagnosis

Suppression of thoracic bone shadows on chest X-rays (CXRs) has been indicated to improve the diagnosis of pulmonary disease. Previous approaches can be categorized as unsupervised physical and supervised deep learning models. Nevertheless, with physical models able to preserve morphological details but at the cost of extremely long processing time, existing DL methods face challenges of gathering sufficient/qualitative ground truth (GT) for robust training, thus leading to failure in maintaining clinically acceptable false positive rates. We hereby propose a generalizable yet efficient workflow of two stages: (1) training pairs generation with GT bone shadows eliminated in by a physical model in spatially transformed gradient fields. (2) fully supervised image denoising network training on stage-one datasets for fast rib removal on incoming CXRs. For step two, we designed a densely connected network called SADXNet, combined with peak signal to noise ratio and multi-scale structure similarity index measure objective minimization to suppress bony structures. The SADXNet organizes spatial filters in U shape (e.g., X=7; filters = 16, 64, 256, 512, 256, 64, 16) and preserves the feature map dimension throughout the network flow. Visually, SADXNet can suppress the rib edge and that near the lung wall/vertebra without jeopardizing the vessel/abnormality conspicuity. Quantitively, it achieves RMSE of ~0 during testing with one prediction taking <1s. Downstream tasks including lung nodule detection as well as common lung disease classification and localization are used to evaluate our proposed rib suppression mechanism. We observed 3.23% and 6.62% area under the curve (AUC) increase as well as 203 and 385 absolute false positive decrease for lung nodule detection and common lung disease localization, separately.

eess.IV

Transformative Technology for FLASH Radiation Therapy: A Snowmass 2021 White Paper

Conventional cancer therapies include surgery, radiation therapy, chemotherapy, and, more recently, immunotherapy. These modalities are often combined to improve the therapeutic index. The general concept of radiation therapy is to increase the therapeutic index by creating a physical dose differential between tumors and normal tissues through precision dose targeting, image guidance, and high radiation beams that deliver radiation dose with high conformality, e.g., protons and ions. However, treatment and cure are still limited by normal tissue radiation toxicity, with many patients experiencing acute and long-term side effects. Recently, however, a fundamentally different paradigm for increasing the therapeutic index of radiation therapy has emerged, supported by preclinical research, and based on the FLASH radiation effect. FLASH radiation therapy (FLASH-RT) is an ultra-high dose-rate delivery of a therapeutic radiation dose within a fraction of a second. Experimental studies have shown that normal tissues seem to be universally spared at these high dose rates, whereas tumors are not. The dose delivery conditions are not yet fully characterized. Still, it is currently estimated that large doses of 10 Gy or more delivered in 200 ms or less produce normal tissue sparing effects yet effectively kill tumor cells. There is a great opportunity, but also many technical challenges, for the accelerator community to create the required dose rates with novel and compact accelerators to ensure the safe delivery of FLASH radiation beams.

physics.med-ph