Radiation Tests of Real-Sized Prototype RPCs for the Future CMS RPC Upscope

We report on a systematic study of double-gap and four-gap phenolic resistive plate chambers (RPCs) for future high-η RPC triggers in the CMS. In the present study, we constructed real-sized double-gap and four-gap RPCs with gap thicknesses of 1.6 and 0.8 mm, respectively, with 2-mm-thick phenolic high-pressure-laminated (HPL) plates. We examined the prototype RPCs for cosmic rays and 100 GeV muons provided by the SPS H4 beam line at CERN. We applied maximum gamma rates of 1.5 kHz cm-2 provided by 137Cs sources at Korea University and the GIF++ irradiation facility installed at the SPS H4 beam line to examine the rate capabilities of the prototype RPCs. In contrast to the case of the four-gap RPCs, we found the relatively high threshold was conducive to effectively suppressing the rapid increase of strip cluster sizes of muon hits with high voltage, especially when measuring the narrow-pitch strips. The gamma-induced currents drawn in the four-gap RPC were about one-fourth of those drawn in the double-gap RPC. The rate capabilities of both RPC types, proven through the present testing using gamma-ray sources, far exceeded the maximum rate expected in the new high-η endcap RPCs planned for future phase-II LHC runs.

physics.ins-det↗

Performance of the gas gain monitoring system of the CMS RPC muon detector

The RPC muon detector of the CMS experiment at the LHC (CERN, Geneva, Switzerland) is equipped with a Gas Gain Monitoring (GGM) system. A report on the stability of the system during the 2011-2012 data taking run is given, as well as the observation of an effect which suggests a novel method for the monitoring of gas mixture composition.

physics.ins-det↗

Simulation of the CMS Resistive Plate Chambers

The Resistive Plate Chamber (RPC) muon subsystem contributes significantly to the formation of the trigger decision and reconstruction of the muon trajectory parameters. Simulation of the RPC response is a crucial part of the entire CMS Monte Carlo software and directly influences the final physical results. An algorithm based on the parametrization of RPC efficiency, noise, cluster size and timing for every strip has been developed. Experimental data obtained from cosmic and proton-proton collisions at $\sqrt{s}=7$ TeV have been used for determination of the parameters. A dedicated validation procedure has been developed. A good agreement between the simulated and experimental data has been achieved.

physics.ins-det↗

Performance of the Gas Gain Monitoring system of the CMS RPC muon detector and effective working point fine tuning

The Gas Gain Monitoring (GGM) system of the Resistive Plate Chamber (RPC) muon detector in the Compact Muon Solenoid (CMS) experiment provides fast and accurate determination of the stability in the working point conditions due to gas mixture changes in the closed loop recirculation system. In 2011 the GGM began to operate using a feedback algorithm to control the applied voltage, in order to keep the GGM response insensitive to environmental temperature and atmospheric pressure variations. Recent results are presented on the feedback method used and on alternative algorithms.

hep-ex↗

The Upgrade of the CMS RPC System during the First LHC Long Shutdown

The CMS muon system includes in both the barrel and endcap region Resistive Plate Chambers (RPC). They mainly serve as trigger detectors and also improve the reconstruction of muon parameters. Over the years, the instantaneous luminosity of the Large Hadron Collider gradually increases. During the LHC Phase 1 (~first 10 years of operation) an ultimate luminosity is expected above its design value of 10^34/cm^2/s at 14 TeV. To prepare the machine and also the experiments for this, two long shutdown periods are scheduled for 2013-2014 and 2018-2019. The CMS Collaboration is planning several detector upgrades during these long shutdowns. In particular, the muon detection system should be able to maintain a low-pT threshold for an efficient Level-1 Muon Trigger at high particle rates. One of the measures to ensure this, is to extend the present RPC system with the addition of a 4th layer in both endcap regions. During the first long shutdown, these two new stations will be equipped in the region |eta|<1.6 with 144 High Pressure Laminate (HPL) double-gap RPCs operating in avalanche mode, with a similar design as the existing CMS endcap chambers. Here, we present the upgrade plans for the CMS RPC system for the fist long shutdown, including trigger simulation studies for the extended system, and details on the new HPL production, the chamber assembly and the quality control procedures.

physics.ins-det↗

Uniformity and Stability of the CMS RPC Detector at the LHC

The Resistive Plate Chambers (RPCs) are employed in the CMS experiment at the LHC as dedicated trigger system both in the barrel and in the endcap. This note presents results of the RPC detector uniformity and stability during the 2011 data taking period, and preliminary results obtained with 2012 data. The detector uniformity has been ensured with a dedicated High Voltage scan with LHC collisions, in order to determine the optimal operating working voltage of each individual RPC chamber installed in CMS. Emphasis is given on the procedures and results of the High Voltage calibration. Moreover, an increased detector stability has been obtained by automatically taking into account temperature and atmospheric pressure variations in the CMS cavern.

physics.ins-det↗

X-ray Properties of Lyman Break Galaxies in the Great Observatories Origins Deep Survey

We constrain the X-ray emission properties of Lyman break galaxies (LBGs) at z ~ 3-6 using the 2 Ms Chandra Deep Field-North and 1 Ms Chandra Deep Field-South. Large samples of LBGs were discovered using HST as part of the Great Observatories Origins Deep Survey (GOODS). Deep optical and X-ray imaging over the GOODS fields have allowed us to place the most significant constraints on the X-ray properties of LBGs to date. Mean X-ray properties of 449, 1734, 629, and 247 LBGs with z ~ 3, 4, 5, and 6, respectively, were determined using stacking techniques. When stacked, we detect X-ray emission from LBGs at z ~ 3 (7 sigma) and from an optically bright subset (brightest 25%) of LBGs at z ~ 4 (3 sigma); the latter is the highest redshift detection yet for "normal" galaxies in the X-ray band. The effective exposure times for these stacked observations are 0.7 and 0.5 Gs, respectively. The derived average rest-frame 2.0-8.0 keV luminosities are 1.5 and 1.4 x 10^41 erg s^-1, respectively. X-ray emission from these LBGs is likely due to high mass X-ray binaries (HMXBs) and Type II supernovae; the corresponding star formation rates are 85-240 M_sol yr^-1. The X-ray to B-band mean luminosity ratio (Lx/LB) at z~3 is somewhat elevated with respect to that measured for starburst galaxies in the local Universe. When stacking full samples of LBGs at z ~ 4, 5, and 6 we do not obtain significant detections and derive rest-frame 2.0-8.0 keV luminosity upper limits of 0.9, 2.8, and 7.1 x 10^41 erg s^-1, respectively. These upper limits constrain any widespread AGN activity in these objects to be modest at best. Furthermore, we find that ~ 0.5% of our LBGs from z ~ 3-6 are detected individually in the X-ray band. Continued ...

astro-ph↗

A new limit of T-violating transverse muon polarization in the $K^{+}\toπ^{0}μ^{+} ν$ decay

A search for T-violating transverse muon polarization ($P_T$) in the $K^{+}\to π^{0}μ^{+}ν$ decay was performed using kaon decays at rest. A new improved value, $P_T= -0.0017\pm 0.0023 (stat)\pm 0.0011 (syst)$, was obtained giving an upper limit, $| P_T | < 0.0050$. The T-violation parameter was determined to be Im$ξ= -0.0053 \pm 0.0071(stat)\pm 0.0036(syst)$ giving an upper limit, $|$Im$ξ| <0.016$.

hep-ex↗