arXiv ScienceSearch

arXiv subjects

K. Knickerbocker

Publications and source records attributed to K. Knickerbocker.

9 recordsLinked to original sources

Axion-Like Particle Search with a Hybrid Cherenkov-Scintillation Detector

This analysis presents the first proof-of-concept search for axion-like particles (ALPs) using a hybrid Cherenkov-scintillation detector at a beam-dump facility. The work is based on the Coherent CAPTAIN-Mills (CCM) experiment, a 10-ton liquid argon light collection detector located at Los Alamos National Laboratory. The CCM200 detector is instrumented with 200 photomultiplier tubes (PMTs), providing approximately 50% photocathode coverage. To enable optical discrimination, 80% of the PMTs are coated with a wavelength-shifting material while the remaining 20% are left uncoated. This configuration, combined with nanosecond-scale timing resolution, provides sensitivity to prompt Cherenkov radiation while maintaining efficient detection of liquid argon scintillation light [1, 2]. This analysis constructs four observables that exploit the Cherenkov emission and event topology expected from ALP-induced electromagnetic interactions. These observables are combined into a likelihood-ratio classifier that provides powerful rejection of steady-state backgrounds. No statistically significant excess above the expected background prediction is observed for $10^{-3}~\mathrm{MeV} < m_a < 10~\mathrm{MeV}$. Nevertheless, the improved background rejection enabled by hybrid Cherenkov-scintillation detection allows this analysis to surpass the sensitivity of the previous CCM120 search [3] despite less exposure and demonstrate the physics potential for hybrid Cherenkov-scintillation detectors.

hep-ex

First Event-by-Event Identification of Cherenkov Radiation from Sub-MeV Particles in Liquid Argon

This Letter reports the event-by-event observation of Cherenkov light from sub-MeV electrons in a high scintillation light-yield liquid argon (LAr) detector by the Coherent CAPTAIN-Mills (CCM) experiment. The CCM200 detector, located at Los Alamos National Laboratory, instruments 7 tons (fiducial volume) of LAr with 200 8-inch photomultiplier tubes (PMTs), 80% of which are coated in a wavelength shifting material and the remaining 20% are uncoated. In the prompt time region of an event, defined as $-6 \leq t < 0$ ns relative to the event start time $t=0$, the uncoated PMTs are primarily sensitive to visible Cherenkov photons. Using gamma-rays from a $^{22}$Na source for production of sub-MeV electrons, we isolated prompt Cherenkov light with $>5\sigma$ confidence and developed a selection to obtain a low-background electromagnetic sample. This is the first event-by-event observation of Cherenkov photons from sub-MeV electrons in a high-yield scintillator detector, and represents a milestone in low-energy particle detector development.

physics.ins-det

Measurement of the Liquid Argon Scintillation Pulse Shape Using Differentiable Simulation in the Coherent CAPTAIN-Mills Experiment

The Coherent CAPTAIN-Mills (CCM) experiment is a liquid argon (LAr) light collection detector searching for MeV-scale neutrino and Beyond Standard Model physics signatures. Two hundred 8-inch photomultiplier tubes (PMTs) instrument the 7 ton fiducial volume with 50% photocathode coverage to detect light produced by charged particles. CCM's light-based approach reduces requirements of LAr purity, compared to other detection technologies, such that sub-MeV particles can be reliably detected without additional LAr filtration and with O(1) parts-per-million of common contaminants. We present a measurement of LAr light production and propagation parameters, with uncertainties, obtained from a sample of MeV-scale electromagnetic events. The optimization of this high-dimensional parameter space was facilitated by a differentiable optical photon Monte-Carlo simulation, and detailed PMT response characterization. This result accurately predicts the timing and spatial distribution of light due to scintillation and Cherenkov emission in the detector. This is the first description of photon propagation in LAr to include several effects, including: anomalous dispersion of the index of refraction near the ultraviolet resonance, Mie scattering from impurities, and Cherenkov light production.

physics.ins-det

Testing Meson Portal Dark Sector Solutions to the MiniBooNE Anomaly at CCM

A solution to the MiniBooNE excess invoking rare three-body decays of the charged pions and kaons to new states in the MeV mass scale was recently proposed as a dark-sector explanation. This class of solution illuminates the fact that, while the charged pions were focused in the target-mode run, their decay products were isotropically suppressed in the beam-dump-mode run in which no excess was observed. This suggests a new physics solution correlated to the mesonic sector. We investigate an extended set of phenomenological models that can explain the MiniBooNE excess as a dark sector solution, utilizing long-lived particles that might be produced in the three-body decays of the charged mesons and the two-body anomalous decays of the neutral mesons. Over a broad set of interactions with the long-lived particles, we show that these scenarios can be compatible with constraints from LSND, KARMEN, and MicroBooNE, and evaluate the sensitivity of the ongoing and future data taken by the Coherent CAPTAIN Mills experiment (CCM) to a potential discovery in this parameter space. See addendum for updated predictions for future MicroBooNE sensitivity.

hep-ph

Prospects for detecting axionlike particles at the Coherent CAPTAIN-Mills experiment

We show results from the Coherent CAPTAIN Mills (CCM) 2019 engineering run which begin to constrain regions of parameter space for axion-like particles (ALPs) produced in electromagnetic particle showers in an 800 MeV proton beam dump, and further investigate the sensitivity of ongoing data-taking campaigns for the CCM200 upgraded detector. Based on beam-on background estimates from the engineering run, we make realistic extrapolations for background reduction based on expected shielding improvements, reduced beam width, and analysis-based techniques for background rejection. We obtain reach projections for two classes of signatures; ALPs coupled primarily to photons can be produced in the tungsten target via the Primakoff process, and then produce a gamma-ray signal in the Liquid Argon (LAr) CCM detector either via inverse Primakoff scattering or decay to a photon pair. ALPs with significant electron couplings have several additional production mechanisms (Compton scattering, $e^+e^-$ annihilation, ALP-bremsstrahlung) and detection modes (inverse Compton scattering, external $e^+e^-$ pair conversion, and decay to $e^+e^-$). In some regions, the constraint is marginally better than both astrophysical and terrestrial constraints. With the beginning of a three year run, CCM will be more sensitive to this parameter space by up to an order of magnitude for both ALP-photon and ALP-electron couplings. The CCM experiment will also have sensitivity to well-motivated parameter space of QCD axion models. It is only a recent realization that accelerator-based large volume liquid argon detectors designed for low energy coherent neutrino and dark matter scattering searches are also ideal for probing ALPs in the unexplored $\sim$MeV mass scale.

hep-ph

First Leptophobic Dark Matter Search from Coherent CAPTAIN-Mills

We report the first results of a search for leptophobic dark matter (DM) from the Coherent CAPTAIN-Mills (CCM) liquid argon (LAr) detector. An engineering run with 120 photomultiplier tubes (PMTs) and $17.9 \times 10^{20}$ protons-on-target (POT) was performed in Fall 2019 to study the characteristics of the CCM detector. The operation of this 10-ton detector was strictly light-based with a threshold of 50 keV and used coherent elastic scattering off argon nuclei to detect DM. Despite only 1.5 months of accumulated luminosity, contaminated LAr, and non-optimized shielding, CCM's first engineering run already achieved sensitivity to previously unexplored parameter space of light dark matter (LDM) models with a baryonic vector portal. With an expected background of 115,005 events, we observe 115,005+16.5 events which is compatible with background expectations. For a benchmark mediator-to-dark matter mass ratio of $m_{_{V_B}}/m_{\chi}=2.1$, DM masses within the range $9\,\text{MeV} \lesssim m_\chi \lesssim 50\,\text{MeV}$ have been excluded at 90% C.L. in the leptophobic model after applying the Feldman-Cousins test statistic. CCM's upgraded run with 200 PMTs, filtered LAr, improved shielding, and ten times more POT will be able to exclude the remaining thermal relic density parameter space of this model, as well as probe new parameter space of other leptophobic DM models.

hep-ex

First Dark Matter Search Results From Coherent CAPTAIN-Mills

This paper describes the operation of the Coherent CAPTAIN-Mills (CCM) detector located at the Lujan Neutron Science Center (LANSCE) at Los Alamos National Laboratory (LANL). CCM is a 10-ton liquid argon (LAr) detector located 20 meters from a high flux neutron/neutrino source and is designed to search for sterile neutrinos ($\nu_s$) and light dark matter (LDM). An engineering run was performed in Fall 2019 to study the characteristics of the CCM120 detector by searching for coherent scattering signals consistent with $\nu_s$'s and LDM resulting from $\pi^+$ and $\pi^0$ decays in the tungsten target. New parameter space in a leptophobic dark matter model was excluded for DM masses between $\sim2.0$ and 30 MeV. The lessons learned from this run have guided the development and construction of the new CCM200 detector that will begin operations in 2021 and significantly improve on these searches.

hep-ex

A modular apparatus for use in high-precision measurements of parity violation in polarized eV neutron transmission`

We describe a modular apparatus for use in parity-violation measurements in epithermal neutron-nucleus resonances with high instantaneous neutron fluxes at the Manuel Lujan Jr.\ Neutron Scattering Center at Los Alamos National Laboratory. This apparatus is designed to conduct high-precision measurements of the parity-odd transmission asymmetry of longitudinally polarized neutrons through targets containing nuclei with p-wave neutron-nucleus resonances in the 0.1-10 eV energy regime and to accommodate a future search for time reversal violation in polarized neutron transmission through polarized nuclear targets. The apparatus consists of an adjustable neutron and gamma collimation system, a \(^3\)He-$^{4}$He ion chamber neutron flux monitor, two identical cryostats for target cooling, an adiabatic eV-neutron spin flipper, a near-unit efficiency \(^6\)Li-\(^{7}\)Li scintillation detector operated in current mode, a flexible CAEN data acquisition system, and a neutron spin filter based on spin-exchange optical pumping of $^{3}$He gas. We describe the features of the apparatus design devoted to the suppression of systematic errors in parity-odd asymmetry measurements. We describe the configuration of the apparatus used to conduct a precision measurement of parity violation at the 0.7 eV p-wave resonance in $^{139}$La which employs two identical $^{139}$La targets, one to polarize the beam on the p-wave resonance using the weak interaction and one to analyze the polarization.

physics.ins-det

The upgraded data acquisition system for beam loss monitoring at the Fermilab Tevatron and Main Injector

A VME-based data acquisition system for beam-loss monitors has been developed and is in use in the Tevatron and Main Injector accelerators at the Fermilab complex. The need for enhanced beam-loss protection when the Tevatron is operating in collider-mode was the main driving force for the new design. Prior to the implementation of the present system, the beam-loss monitor system was disabled during collider operation and protection of the Tevatron magnets relied on the quench protection system. The new Beam-Loss Monitor system allows appropriate abort logic and thresholds to be set over the full set of collider operating conditions. The system also records a history of beam-loss data prior to a beam-abort event for post-abort analysis. Installation of the Main Injector system occurred in the fall of 2006 and the Tevatron system in the summer of 2007. Both systems were fully operation by the summer of 2008. In this paper we report on the overall system design, provide a description of its normal operation, and show a number of examples of its use in both the Main Injector and Tevatron.

physics.ins-det