arXiv ScienceSearch

arXiv subjects

K. Clarke

Publications and source records attributed to K. Clarke.

5 recordsLinked to original sources

AION-10: Technical Design Report for a 10m Atom Interferometer in Oxford

This Technical Design Report presents AION-10, a 10-meter atom interferometer to be located at Oxford University using ultracold strontium atoms to make precision measurements of fundamental physics. AION-10 serves as both a prototype for future larger-scale experiments and a versatile scientific instrument capable of conducting its own diverse physics programme. The design features a 10-meter vertical tower housing two atom interferometer sources in an ultra-high vacuum environment. Key engineering challenges include achieving nanometer-level vibrational stability and precise magnetic field control. Solutions include active vibration isolation, specialized magnetic shielding, and a modular assembly approach using professional lifting equipment. Detailed analysis confirms the design meets all performance requirements, with critical optical components remaining within our specifications 97% of the time under realistic operating conditions. Vacuum and vibration measurements in the host building validate that the instrument will achieve the precision needed for quantum sensing applications. This work establishes the technical foundation for scaling atom interferometry to longer baselines while creating a cutting-edge facility for precision measurements that could advance our understanding of fundamental physics.

physics.atom-ph

A prototype differential atom interferometer for fundamental physics

Gravitational waves and ultralight dark matter are among the most compelling frontiers in fundamental physics, motivating proposals for Very Long-Baseline Atom Interferometers (VLBAIs) such as AION, MAGIS, AICE and AEDGE that aim to detect frequencies at which ground-based and space-borne laser interferometers lose sensitivity. VLBAIs look for signals by comparing the quantum phase evolution of widely separated atomic ensembles interrogated by a common laser. However, their performance depends critically on suppressing noise sources, particularly laser phase noise. Experimental validation of such noise rejection remains an important challenge. Here we demonstrate a prototype differential atom interferometer based on the single-photon clock transition of fermionic 87Sr, realising for the first time a gradiometer configuration with a species intrinsically suited to kilometre-scale and space-baseline operation. The instrument operates at the Standard Quantum Limit with no excess noise beyond atom shot noise, and the differential configuration maintains quantum-limited sensitivity in the presence of several radians of artificially injected laser phase noise per shot, emulating the conditions expected in a VLBAI. We further demonstrate recovery of coherent oscillatory signals across a broad frequency range under fully phase-randomised conditions, a capability that is inaccessible to a single interferometer operating in the same regime. These results provide an experimental validation of the noise-immune measurement principle underlying VLBAIs and mark an important step towards next-generation quantum sensors for gravitational-wave detection and searches for ultralight dark matter.

hep-ex

Centralised Design and Production of the Ultra-High Vacuum and Laser-Stabilisation Systems for the AION Ultra-Cold Strontium Laboratories

This paper outlines the centralised design and production of the Ultra-High-Vacuum sidearm and Laser-Stabilisation systems for the AION Ultra-Cold Strontium Laboratories. Commissioning data on the residual gas and steady-state pressures in the sidearm chambers, on magnetic field quality, on laser stabilisation, and on the loading rate for the 3D Magneto-Optical Trap are presented. Streamlining the design and production of the sidearm and laser stabilisation systems enabled the AION Collaboration to build and equip in parallel five state-of-the-art Ultra-Cold Strontium Laboratories within 24 months by leveraging key expertise in the collaboration. This approach could serve as a model for the development and construction of other cold atom experiments, such as atomic clock experiments and neutral atom quantum computing systems, by establishing dedicated design and production units at national laboratories.

physics.atom-ph

Morphological stability of solid-liquid interfaces under additive manufacturing conditions

Understanding rapid solidification behavior at velocities relevant to additive manufacturing (AM) is critical to controlling microstructure selection. Although in-situ visualization of solidification dynamics is now possible, systematic studies under AM conditions with microstructural outcomes compared to solidification theory remain lacking. Here we measure solid-liquid interface velocities of Ni-Mo-Al alloy single crystals under AM conditions with synchrotron X-ray imaging, characterize the microstructures, and show discrepancies with classical theories regarding the onset velocity for absolute stability of a planar solid-liquid interface. Experimental observations reveal cellular/dendritic microstructures can persist at velocities larger than the expected absolute stability limit, where banded structure formation should theoretically appear. We show that theory and experimental observations can be reconciled by properly accounting for the effect of solute trapping and kinetic undercooling on the velocity-dependent solidus and liquidus temperatures of the alloy. Further theoretical developments and accurate assessments of key thermophysical parameters - like liquid diffusivities, solid-liquid interface excess free energies, and kinetic coefficients - remain needed to quantitatively investigate such discrepancies and pave the way for the prediction and control of microstructure selection under rapid solidification conditions.

cond-mat.mtrl-sci

Comparing the Corrosion of Uranium Nitride and Uranium Dioxide Surfaces with H2O2

Uranium mononitride, UN, is considered a potential accident tolerant fuel due to its high uranium density, high thermal conductivity, and high melting point. Compared with the relatively inert UO2, UN has a high reactivity in water, however, studies have not considered the significant effect of radiation, which is known to cause corrosion of UO2. This study uses 0.1 M H2O2 to simulate the effects of water radiolysis in order to compare the radiolytic corrosion rates of UO2, UN, and U2N3 thin films at room temperature. X-ray reflectivity was used to investigate the changes in film morphology as a function of H2O2 exposure time, allowing changes in film thickness and roughness to be observed on the Angstrom length-scale. Results showed significant differences between UO2, UN, and U2N3, with corrosion rates of 0.083(3), 0.020(4), and 0.47(8) A/s, respectively, showing that UN corrodes more slowly than UO2 in 0.1 M H2O2.

cond-mat.mtrl-sci