arXiv ScienceSearch

arXiv subjects

Justin Roper

Publications and source records attributed to Justin Roper.

At least 19 recordsLinked to original sources

One-for-All Adaptive Radiotherapy Planning Agent: A Foundation Framework for Daily CBCT-guided Radiotherapy

In this work, we introduce the One-for-All Adaptive Radiotherapy Planning Agent, a unified foundation-model-based system that performs complete, treatment-specific online adaptive planning directly from daily cone-beam CT in under two minutes. The agent first autonomously predicts all essential planning components, including synthetic CT generation, multimodal alignment, and tumor/organ segmentation. It then intelligently leverages these outputs to execute the final clinical plan design, providing a comprehensive, automated solution for daily treatment. We also demonstrate that the agent enables clinicians to define planning with intent and intervene at critical decision points, ensuring a "human-in-the-loop" framework that generates acceptable plans before final approval. Evaluated on multiple datasets spanning head-and-neck, lung, abdominal, and prostate cancers with both photon and proton therapy, the proposed framework achieves clinically acceptable accuracy and plan quality comparable to clinically generated treatment plans, with target dose errors (D98) generally within 2.0 Gy of the reference plan. The strong performance of the One-for-All agent highlights the promise of a unified foundation-model approach and opens opportunities for fast, scalable, and fully automated online adaptive radiotherapy across diverse clinical scenarios.

physics.med-ph

An Efficient 3D Latent Diffusion Model for T1-contrast Enhanced MRI Generation

Objective: Gadolinium-based contrast agents (GBCAs) are commonly employed with T1w MRI to enhance lesion visualization but are restricted in patients at risk of nephrogenic systemic fibrosis and variations in GBCA administration can introduce imaging inconsistencies. This study develops an efficient 3D deep-learning framework to generate T1-contrast enhanced images (T1C) from pre-contrast multiparametric MRI. Approach: We propose the 3D latent rectified flow (T1C-RFlow) model for generating high-quality T1C images. First, T1w and T2-FLAIR images are input into a pretrained autoencoder to acquire an efficient latent space representation. A rectified flow diffusion model is then trained in this latent space representation. The T1C-RFlow model was trained on a curated dataset comprised of the BraTS 2024 glioma (GLI; 1480 patients), meningioma (MEN; 1141 patients), and metastases (MET; 1475 patients) datasets. Selected patients were split into train (N=2860), validation (N=612), and test (N=614) sets. Results: Both qualitative and quantitative results demonstrate that the T1C-RFlow model outperforms benchmark 3D models (pix2pix, DDPM, Diffusion Transformers (DiT-3D)) trained in the same latent space. T1C-RFlow achieved the following metrics - GLI: NMSE 0.044 +/- 0.047, SSIM 0.935 +/- 0.025; MEN: NMSE 0.046 +/- 0.029, SSIM 0.937 +/- 0.021; MET: NMSE 0.098 +/- 0.088, SSIM 0.905 +/- 0.082. T1C-RFlow had the best tumor reconstruction performance and significantly faster denoising times (6.9 s/volume, 200 steps) than conventional DDPM models in both latent space (37.7s, 1000 steps) and patch-based in image space (4.3 hr/volume). Significance: Our proposed method generates synthetic T1C images that closely resemble ground truth T1C in much less time than previous diffusion models. Further development may permit a practical method for contrast-agent-free MRI for brain tumors.

cs.CV

Unifying Biomedical Vision-Language Expertise: Towards a Generalist Foundation Model via Multi-CLIP Knowledge Distillation

CLIP models pretrained on natural images with billion-scale image-text pairs have demonstrated impressive capabilities in zero-shot classification, cross-modal retrieval, and open-ended visual answering. However, transferring this success to biomedicine is hindered by the scarcity of large-scale biomedical image-text corpora, the heterogeneity of image modalities, and fragmented data standards across institutions. These limitations hinder the development of a unified and generalizable biomedical foundation model trained from scratch. To overcome this, we introduce MMKD-CLIP, a generalist biomedical foundation model developed via Multiple Medical CLIP Knowledge Distillation. Rather than relying on billion-scale raw data, MMKD-CLIP distills knowledge from nine state-of-the-art domain-specific or generalist biomedical CLIP models, each pretrained on millions of biomedical image-text pairs. Our two-stage training pipeline first performs CLIP-style pretraining on over 2.9 million biomedical image-text pairs from 26 image modalities, followed by feature-level distillation using over 19.2 million feature pairs extracted from teacher models. We evaluate MMKD-CLIP on 58 diverse biomedical datasets, encompassing over 10.8 million biomedical images across nine image modalities. The evaluation spans six core task types: zero-shot classification, linear probing, cross-modal retrieval, visual question answering, survival prediction, and cancer diagnosis. MMKD-CLIP consistently outperforms all teacher models while demonstrating remarkable robustness and generalization across image domains and task settings. These results underscore that multi-teacher knowledge distillation is a scalable and effective paradigm for building high-performing biomedical foundation models under the practical constraints of real-world data availability.

cs.CV

Limited-Angle CBCT Reconstruction via Geometry-Integrated Cycle-domain Denoising Diffusion Probabilistic Models

Cone-beam CT (CBCT) is widely used in clinical radiotherapy for image-guided treatment, improving setup accuracy, adaptive planning, and motion management. However, slow gantry rotation limits performance by introducing motion artifacts, blurring, and increased dose. This work aims to develop a clinically feasible method for reconstructing high-quality CBCT volumes from consecutive limited-angle acquisitions, addressing imaging challenges in time- or dose-constrained settings. We propose a limited-angle (LA) geometry-integrated cycle-domain (LA-GICD) framework for CBCT reconstruction, comprising two denoising diffusion probabilistic models (DDPMs) connected via analytic cone-beam forward and back projectors. A Projection-DDPM completes missing projections, followed by back-projection, and an Image-DDPM refines the volume. This dual-domain design leverages complementary priors from projection and image spaces to achieve high-quality reconstructions from limited-angle (<= 90 degrees) scans. Performance was evaluated against full-angle reconstruction. Four board-certified medical physicists conducted assessments. A total of 78 planning CTs in common CBCT geometries were used for training and evaluation. The method achieved a mean absolute error of 35.5 HU, SSIM of 0.84, and PSNR of 29.8 dB, with visibly reduced artifacts and improved soft-tissue clarity. LA-GICD's geometry-aware dual-domain learning, embedded in analytic forward/backward operators, enabled artifact-free, high-contrast reconstructions from a single 90-degree scan, reducing acquisition time and dose four-fold. LA-GICD improves limited-angle CBCT reconstruction with strong data fidelity and anatomical realism. It offers a practical solution for short-arc acquisitions, enhancing CBCT use in radiotherapy by providing clinically applicable images with reduced scan time and dose for more accurate, personalized treatments.

cs.CV

A Large Convolutional Neural Network for Clinical Target and Multi-organ Segmentation in Gynecologic Brachytherapy with Multi-stage Learning

Purpose: Accurate segmentation of clinical target volumes (CTV) and organs-at-risk is crucial for optimizing gynecologic brachytherapy (GYN-BT) treatment planning. However, anatomical variability, low soft-tissue contrast in CT imaging, and limited annotated datasets pose significant challenges. This study presents GynBTNet, a novel multi-stage learning framework designed to enhance segmentation performance through self-supervised pretraining and hierarchical fine-tuning strategies. Methods: GynBTNet employs a three-stage training strategy: (1) self-supervised pretraining on large-scale CT datasets using sparse submanifold convolution to capture robust anatomical representations, (2) supervised fine-tuning on a comprehensive multi-organ segmentation dataset to refine feature extraction, and (3) task-specific fine-tuning on a dedicated GYN-BT dataset to optimize segmentation performance for clinical applications. The model was evaluated against state-of-the-art methods using the Dice Similarity Coefficient (DSC), 95th percentile Hausdorff Distance (HD95), and Average Surface Distance (ASD). Results: Our GynBTNet achieved superior segmentation performance, significantly outperforming nnU-Net and Swin-UNETR. Notably, it yielded a DSC of 0.837 +/- 0.068 for CTV, 0.940 +/- 0.052 for the bladder, 0.842 +/- 0.070 for the rectum, and 0.871 +/- 0.047 for the uterus, with reduced HD95 and ASD compared to baseline models. Self-supervised pretraining led to consistent performance improvements, particularly for structures with complex boundaries. However, segmentation of the sigmoid colon remained challenging, likely due to anatomical ambiguities and inter-patient variability. Statistical significance analysis confirmed that GynBTNet's improvements were significant compared to baseline models.

cs.CV

Triad: Vision Foundation Model for 3D Magnetic Resonance Imaging

Vision foundation models (VFMs) are pre-trained on extensive image datasets to learn general representations for diverse types of data. These models can subsequently be fine-tuned for specific downstream tasks, significantly boosting performance across a broad range of applications. However, existing vision foundation models that claim to be applicable to various clinical tasks are mostly pre-trained on 3D computed tomography (CT), which benefits from the availability of extensive 3D CT databases. Significant differences between CT and magnetic resonance imaging (MRI) in imaging principles, signal characteristics, and data distribution may hinder their practical performance and versatility in MRI-specific applications. Here, we propose Triad, a vision foundation model for 3D MRI. Triad adopts a widely used autoencoder architecture to learn robust representations from 131,170 3D MRI volumes and uses organ-independent imaging descriptions to constrain the semantic distribution of the visual modality. The above pre-training dataset is called Triad-131K, which is currently the largest 3D MRI pre-training dataset. We evaluate Triad across three tasks, namely, organ/tumor segmentation, organ/cancer classification, and medical image registration, in two data modalities (within-domain and out-of-domain) settings using 25 downstream datasets. By initializing models with Triad's pre-trained weights, nnUNet-Triad improves segmentation performance by 2.51% compared to nnUNet-Scratch across 17 datasets. Swin-B-Triad achieves a 3.97% improvement over Swin-B-Scratch in classification tasks across five datasets. SwinUNETR-Triad improves by 4.00% compared to SwinUNETR-Scratch in registration tasks across two datasets. Our study demonstrates that pre-training can improve performance when the data modalities and organs of upstream and downstream tasks are consistent.

cs.CV

Stereotactic Arrhythmia Radioablation for Refractory Ventricular Tachycardia: A Narrative Review and Exploratory Pooled Analysis of Clinical Outcomes and Toxicity

Purpose: Stereotactic arrhythmia radioablation (STAR) is a non-invasive salvage therapy for refractory ventricular tachycardia (VT), especially in patients ineligible for catheter ablation. This narrative review and pooled analysis evaluates the safety, efficacy, and technical characteristics of STAR, integrating preclinical studies, case reports, case series, and clinical trials. Methods and Materials: A comprehensive review identified 86 studies published between 2015 and 2025, including 12 preclinical studies, 49 case reports, 18 case series, and 7 clinical trials. Study-level data were extracted for pooled analysis of 6- and 12-month mortality, VT burden reduction, and grade 3+ acute toxicities. Subgroup analyses were performed by delivery modality, age, left ventricular ejection fraction (LVEF), and cardiomyopathy type. Results: Pooled mortality was 16% (95% CI: 11-20%) at 6 months and 33% (95% CI: 27-38%) at 12 months. VT burden reduction at 6 months averaged 75% (95% CI: 73-77%) but showed substantial heterogeneity (I^2 = 98.8%). Grade 3+ acute toxicities occurred in 7% (95% CI: 4-10%), with heart failure being most common. Subgroup analyses suggested better outcomes in younger patients, those with NICM, and those with higher LVEF. Conclusions: STAR is a promising salvage therapy with favorable acute safety and efficacy. Outcome heterogeneity and inconsistent reporting highlight the need for standardized definitions, dosimetric protocols, and longer-term follow-up. Prospective trials and real-world registries are critical for refining STAR's role in VT management.

physics.med-ph

A Comparative Dosimetric Study of Proton and Photon Therapy in Stereotactic Arrhythmia Radioablation for Ventricular Tachycardia

Purpose: VT is a life-threatening arrhythmia commonly treated with catheter ablation; however, some cases remain refractory to conventional treatment. STAR has emerged as a non-invasive option for such patients. While photon-based STAR has shown efficacy, proton therapy offers potential advantages due to its superior dose conformity and sparing of critical OARs, including the heart itself. This study aims to investigate and compare the dosimetry between proton and photon therapy for VT, focusing on target coverage and OAR sparing. Methods: We performed a retrospective study on a cohort of 34 VT patients who received photon STAR. Proton STAR plans were generated using robust optimization in RayStation to deliver the same prescription dose of 25 Gy in a single fraction while minimizing dose to OARs. Dosimetric metrics, including D99, D95, Dmean, and D0.03cc, were extracted for critical OARs and VAS. Shapiro-Wilk tests were used to assess normality, followed by paired t-tests or Wilcoxon signed-rank tests for statistical comparisons between modalities, with Bonferroni correction applied for multiple comparisons. Results: Proton and photon plans achieved comparable target coverage, with VAS D95 of 24.1 +/- 1.2 Gy vs. 24.7 +/- 1.0 Gy (p=0.294). Proton therapy significantly reduced OAR doses, including heart Dmean (3.6 +/- 1.5 Gy vs. 5.5 +/- 2.0 Gy, p<0.001), lungs Dmean (1.6 +/- 1.5 Gy vs. 2.1 +/- 1.4 Gy, p<0.001), and esophagus Dmean (0.3 +/- 0.6 Gy vs. 1.6 +/- 1.3 Gy, p<0.001), while maintaining optimal target coverage. Conclusion: Proton therapy for STAR demonstrates significant dosimetric advantages in sparing the heart and other critical OARs compared to photon therapy for VT, while maintaining equivalent target coverage. These findings highlight the potential of proton therapy to reduce treatment-related toxicity and improve outcomes for VT patients.

physics.med-ph

Photon-Counting CT in Cancer Radiotherapy: Technological Advances and Clinical Benefits

Photon-counting computed tomography (PCCT) marks a significant advancement over conventional energy-integrating detector (EID) CT systems. This review highlights PCCT's superior spatial and contrast resolution, reduced radiation dose, and multi-energy imaging capabilities, which address key challenges in radiotherapy, such as accurate tumor delineation, precise dose calculation, and treatment response monitoring. PCCT's improved anatomical clarity enhances tumor targeting while minimizing damage to surrounding healthy tissues. Additionally, metal artifact reduction (MAR) and quantitative imaging capabilities optimize workflows, enabling adaptive radiotherapy and radiomics-driven personalized treatment. Emerging clinical applications in brachytherapy and radiopharmaceutical therapy (RPT) show promising outcomes, although challenges like high costs and limited software integration remain. With advancements in artificial intelligence (AI) and dedicated radiotherapy packages, PCCT is poised to transform precision, safety, and efficacy in cancer radiotherapy, marking it as a pivotal technology for future clinical practice.

physics.med-ph

Optimization-Based Image Reconstruction Regularized with Inter-Spectral Structural Similarity for Limited-Angle Dual-Energy Cone-Beam CT

Background: Limited-angle (LA) dual-energy (DE) cone-beam CT (CBCT) is considered as a potential solution to achieve fast and low-dose DE imaging on current CBCT scanners without hardware modification. However, its clinical implementations are hindered by the challenging image reconstruction from LA projections. While optimization-based and deep learning-based methods have been proposed for image reconstruction, their utilization is limited by the requirement for X-ray spectra measurement or paired datasets for model training. Purpose: This work aims to facilitate the clinical applications of fast and low-dose DECBCT by developing a practical solution for image reconstruction in LA-DECBCT. Methods: An inter-spectral structural similarity-based regularization was integrated into the iterative image reconstruction in LA-DECBCT. By enforcing the similarity between the DE images, LA artifacts were efficiently reduced in the reconstructed DECBCT images. The proposed method was evaluated using four physical phantoms and three digital phantoms, demonstrating its efficacy in quantitative DECBCT imaging. Conclusions: The proposed method achieves accurate image reconstruction without the need for X-ray spectra measurement for optimization or paired datasets for model training, showing great practical value in clinical implementations of LA-DECBCT.

physics.med-ph

Diffeomorphic Transformer-based Abdomen MRI-CT Deformable Image Registration

This paper aims to create a deep learning framework that can estimate the deformation vector field (DVF) for directly registering abdominal MRI-CT images. The proposed method assumed a diffeomorphic deformation. By using topology-preserved deformation features extracted from the probabilistic diffeomorphic registration model, abdominal motion can be accurately obtained and utilized for DVF estimation. The model integrated Swin transformers, which have demonstrated superior performance in motion tracking, into the convolutional neural network (CNN) for deformation feature extraction. The model was optimized using a cross-modality image similarity loss and a surface matching loss. To compute the image loss, a modality-independent neighborhood descriptor (MIND) was used between the deformed MRI and CT images. The surface matching loss was determined by measuring the distance between the warped coordinates of the surfaces of contoured structures on the MRI and CT images. The deformed MRI image was assessed against the CT image using the target registration error (TRE), Dice similarity coefficient (DSC), and mean surface distance (MSD) between the deformed contours of the MRI image and manual contours of the CT image. When compared to only rigid registration, DIR with the proposed method resulted in an increase of the mean DSC values of the liver and portal vein from 0.850 and 0.628 to 0.903 and 0.763, a decrease of the mean MSD of the liver from 7.216 mm to 3.232 mm, and a decrease of the TRE from 26.238 mm to 8.492 mm. The proposed deformable image registration method based on a diffeomorphic transformer provides an effective and efficient way to generate an accurate DVF from an MRI-CT image pair of the abdomen. It could be utilized in the current treatment planning workflow for liver radiotherapy.

cs.CV

Dual-Energy Cone-Beam CT Using Two Complementary Limited-Angle Scans with A Projection-Consistent Diffusion Model

Background: Dual-energy imaging on cone-beam CT (CBCT) scanners has great potential in different clinical applications, including image-guided surgery and adaptive proton therapy. However, the clinical practice of dual-energy CBCT (DE-CBCT) has been hindered by the requirement of sophisticated hardware components. Purpose: In this work, we aim to propose a practical solution for single-scan dual-energy imaging on current CBCT scanners without hardware modifications, using two complementary limited-angle scans with a projection-consistent diffusion model. Methods: Our approach has two major components: data acquisition using two complementary limited-angle scans, and dual-energy projections restoration with subsequent FDK reconstruction. Two complementary scans at different kVps are performed in a single rotation by switching the tube voltage at the middle of the source trajectory, acquiring the mixed-spectra projection in a single CBCT scan. Full-sampled dual-energy projections are then restored by a projection-consistent diffusion model in a slice-by-slice manner, followed by the DE-CBCT reconstruction using the FDK algorithm. Results: The proposed method was evaluated in a simulation study of digital abdomen phantoms and a study of real rat data. In the simulation study, the proposed method produced DE-CBCT images at a mean absolute error (MAE) of 20 HU. In the small-animal study, reconstructed DE-CBCT images using the proposed method gave an MAE of 25 HU. Conclusion: This study demonstrates the feasibility of DE-CBCT imaging using two complementary limited-angle scans with a projection-consistent diffusion model in both half-fan and short scans. The proposed method may allow quantitative applications of DE-CBCT and enable DE-CBCT-based adaptive proton therapy.

physics.med-ph

Image-Domain Material Decomposition for Dual-energy CT using Unsupervised Learning with Data-fidelity Loss

Background: Dual-energy CT (DECT) and material decomposition play vital roles in quantitative medical imaging. However, the decomposition process may suffer from significant noise amplification, leading to severely degraded image signal-to-noise ratios (SNRs). While existing iterative algorithms perform noise suppression using different image priors, these heuristic image priors cannot accurately represent the features of the target image manifold. Although deep learning-based decomposition methods have been reported, these methods are in the supervised-learning framework requiring paired data for training, which is not readily available in clinical settings. Purpose: This work aims to develop an unsupervised-learning framework with data-measurement consistency for image-domain material decomposition in DECT.

physics.med-ph

Full-dose Whole-body PET Synthesis from Low-dose PET Using High-efficiency Denoising Diffusion Probabilistic Model: PET Consistency Model

Objective: Positron Emission Tomography (PET) has been a commonly used imaging modality in broad clinical applications. One of the most important tradeoffs in PET imaging is between image quality and radiation dose: high image quality comes with high radiation exposure. Improving image quality is desirable for all clinical applications while minimizing radiation exposure is needed to reduce risk to patients. Approach: We introduce PET Consistency Model (PET-CM), an efficient diffusion-based method for generating high-quality full-dose PET images from low-dose PET images. It employs a two-step process, adding Gaussian noise to full-dose PET images in the forward diffusion, and then denoising them using a PET Shifted-window Vision Transformer (PET-VIT) network in the reverse diffusion. The PET-VIT network learns a consistency function that enables direct denoising of Gaussian noise into clean full-dose PET images. PET-CM achieves state-of-the-art image quality while requiring significantly less computation time than other methods. Results: In experiments comparing eighth-dose to full-dose images, PET-CM demonstrated impressive performance with NMAE of 1.278+/-0.122%, PSNR of 33.783+/-0.824dB, SSIM of 0.964+/-0.009, NCC of 0.968+/-0.011, HRS of 4.543, and SUV Error of 0.255+/-0.318%, with an average generation time of 62 seconds per patient. This is a significant improvement compared to the state-of-the-art diffusion-based model with PET-CM reaching this result 12x faster. Similarly, in the quarter-dose to full-dose image experiments, PET-CM delivered competitive outcomes, achieving an NMAE of 0.973+/-0.066%, PSNR of 36.172+/-0.801dB, SSIM of 0.984+/-0.004, NCC of 0.990+/-0.005, HRS of 4.428, and SUV Error of 0.151+/-0.192% using the same generation process, which underlining its high quantitative and clinical precision in both denoising scenario.

eess.IV

One-step Iterative Estimation of Effective Atomic Number and Electron Density for Dual Energy CT

Dual-energy computed tomography (DECT) is a promising technology that has shown a number of clinical advantages over conventional X-ray CT, such as improved material identification, artifact suppression, etc. For proton therapy treatment planning, besides material-selective images, maps of effective atomic number (Z) and relative electron density to that of water ($\rho_e$) can also be achieved and further employed to improve stopping power ratio accuracy and reduce range uncertainty. In this work, we propose a one-step iterative estimation method, which employs multi-domain gradient $L_0$-norm minimization, for Z and $\rho_e$ maps reconstruction. The algorithm was implemented on GPU to accelerate the predictive procedure and to support potential real-time adaptive treatment planning. The performance of the proposed method is demonstrated via both phantom and patient studies.

physics.med-ph

Hippocampus Substructure Segmentation Using Morphological Vision Transformer Learning

Background: The hippocampus plays a crucial role in memory and cognition. Because of the associated toxicity from whole brain radiotherapy, more advanced treatment planning techniques prioritize hippocampal avoidance, which depends on an accurate segmentation of the small and complexly shaped hippocampus. Purpose: To achieve accurate segmentation of the anterior and posterior regions of the hippocampus from T1 weighted (T1w) MRI images, we developed a novel model, Hippo-Net, which uses a mutually enhanced strategy. Methods: The proposed model consists of two major parts: 1) a localization model is used to detect the volume-of-interest (VOI) of hippocampus. 2) An end-to-end morphological vision transformer network is used to perform substructures segmentation within the hippocampus VOI. A total of 260 T1w MRI datasets were used in this study. We conducted a five-fold cross-validation on the first 200 T1w MR images and then performed a hold-out test on the remaining 60 T1w MR images with the model trained on the first 200 images. Results: In five-fold cross-validation, the DSCs were 0.900+-0.029 and 0.886+-0.031for the hippocampus proper and parts of the subiculum, respectively. The MSD were 0.426+-0.115mm and 0.401+-0.100 mm for the hippocampus proper and parts of the subiculum, respectively. Conclusions: The proposed method showed great promise in automatically delineating hippocampus substructures on T1w MRI images. It may facilitate the current clinical workflow and reduce the physician effort.

physics.med-ph

Synthetic CT Generation from MRI using 3D Transformer-based Denoising Diffusion Model

Magnetic resonance imaging (MRI)-based synthetic computed tomography (sCT) simplifies radiation therapy treatment planning by eliminating the need for CT simulation and error-prone image registration, ultimately reducing patient radiation dose and setup uncertainty. We propose an MRI-to-CT transformer-based denoising diffusion probabilistic model (MC-DDPM) to transform MRI into high-quality sCT to facilitate radiation treatment planning. MC-DDPM implements diffusion processes with a shifted-window transformer network to generate sCT from MRI. The proposed model consists of two processes: a forward process which adds Gaussian noise to real CT scans, and a reverse process in which a shifted-window transformer V-net (Swin-Vnet) denoises the noisy CT scans conditioned on the MRI from the same patient to produce noise-free CT scans. With an optimally trained Swin-Vnet, the reverse diffusion process was used to generate sCT scans matching MRI anatomy. We evaluated the proposed method by generating sCT from MRI on a brain dataset and a prostate dataset. Qualitative evaluation was performed using the mean absolute error (MAE) of Hounsfield unit (HU), peak signal to noise ratio (PSNR), multi-scale Structure Similarity index (MS-SSIM) and normalized cross correlation (NCC) indexes between ground truth CTs and sCTs. MC-DDPM generated brain sCTs with state-of-the-art quantitative results with MAE 43.317 HU, PSNR 27.046 dB, SSIM 0.965, and NCC 0.983. For the prostate dataset, MC-DDPM achieved MAE 59.953 HU, PSNR 26.920 dB, SSIM 0.849, and NCC 0.948. In conclusion, we have developed and validated a novel approach for generating CT images from routine MRIs using a transformer-based DDPM. This model effectively captures the complex relationship between CT and MRI images, allowing for robust and high-quality synthetic CT (sCT) images to be generated in minutes.

eess.IV

Cross-Shaped Windows Transformer with Self-supervised Pretraining for Clinically Significant Prostate Cancer Detection in Bi-parametric MRI

Biparametric magnetic resonance imaging (bpMRI) has demonstrated promising results in prostate cancer (PCa) detection using convolutional neural networks (CNNs). Recently, transformers have achieved competitive performance compared to CNNs in computer vision. Large scale transformers need abundant annotated data for training, which are difficult to obtain in medical imaging. Self-supervised learning (SSL) utilizes unlabeled data to generate meaningful semantic representations without the need for costly annotations, enhancing model performance on tasks with limited labeled data. We introduce a novel end-to-end Cross-Shaped windows (CSwin) transformer UNet model, CSwin UNet, to detect clinically significant prostate cancer (csPCa) in prostate bi-parametric MR imaging (bpMRI) and demonstrate the effectiveness of our proposed self-supervised pre-training framework. Using a large prostate bpMRI dataset with 1500 patients, we first pretrain CSwin transformer using multi-task self-supervised learning to improve data-efficiency and network generalizability. We then finetune using lesion annotations to perform csPCa detection. Five-fold cross validation shows that self-supervised CSwin UNet achieves 0.888 AUC and 0.545 Average Precision (AP), significantly outperforming four comparable models (Swin UNETR, DynUNet, Attention UNet, UNet). Using a separate bpMRI dataset with 158 patients, we evaluate our method robustness to external hold-out data. Self-supervised CSwin UNet achieves 0.79 AUC and 0.45 AP, still outperforming all other comparable methods and demonstrating good generalization to external data.

eess.IV