Hydrodynamic modeling of liquid metal field emitter deformation under combined RF and DC magnetic fields

Radio-frequency (RF) breakdowns, also known as vacuum (or electrical) arcs and breakdowns, or electrical discharges, have been studied for over decades, but the mechanisms of the RF breakdown are still questionable. This phenomenon reduces the stability of the beam, damages the RF cavities, and thus limits the achievable accelerating field in the particle accelerator. In the case of Muon Collider, the RF cavities have to withstand an electric field of the order of multi tens of MV/m and a DC magnetic field of a few tens of teslas, with a minimum rate of RF breakdown. Different models have been proposed, and some important factors that could lead to the RF breakdown have been identified, such as the field emission current, irregularity of the surface , presence of hot particles on the surface and the role of the DC magnetic field. In this paper, we give insights to the mechanism of RF breakdowns using a hydrodynamic and a magnetohydrodynamic approach, focusing on understanding the forces that deform the liquid copper emitter. We found that if the local RF electric field is sufficiently high, it could provoke the emission of hot copper droplets into the cavity. Our simulations use the computational fluid dynamics module, the magnetic and electric field module, and the level set method in the COMSOL software to simulate the behavior of a copper liquid emitter with the Navier-Stokes equation under the influence of the pressure radiation, and the surface tension force.

physics.acc-ph↗

Experimental study of second sound quench detection for superconducting cavities

Superconducting RF cavities are used in particle accelerators to provide energy to the particle beam. Such cavities are mostly fabricated in niobium and often operated in superfluid helium. One of their limits of operation is the appearance of a local quench, initiated by a local field enhancement due to a defect, which leads to a normal conducting transition of the cavity. Localizing the quench area can be achieved with temperature mapping systems. Another method is the use of second sound wave propagation in superfluid helium. Measuring the time of propagation of these waves from quench location to special sensors, called Oscillating Superleak Transducers (OSTs), and using their well-known velocity should allow trilateration. However, most of experimental measurements on cavities show "premature signals", i.e. the second sound signals arrive earlier on the OSTs than expected. This paper presents several quench experiments on cavities equipped with OSTs and temperature mapping quench detection systems. Two hypotheses can explain the observed premature signals. The first one assesses faster propagation in helium. An experimental setup has been developed for testing this hypothesis, where second sound is created by a localized heater in a controlled environment up to 4.3 kW/cm2 and 2.8 J. Premature signals could not be verified in this setup. A second hypothesis based on a simple model including several processes in niobium and second sound propagation in helium is discussed. The model improves significantly the prediction of the times of arrival of the second sound waves. The overall study shows that the processes in niobium play a prominent role in the second sound detection for superconducting cavities.

physics.acc-ph↗

Design, fabrication and test of a 5 GHz klystron based on the kladistron principle

A new bunching method, named "kladistron" has been developed at CEA in order to provide high efficiency klystrons. A first "kladistron" prototype was designed and realized. It was adapted from the 4.9 GHz TH2166 from Thales, where the interaction line was transformed from 6 to 16 cavities. The design and fabrication phases of this prototype are developed in this paper. The kladistron prototype was tested in Thales facility. Its efficiency is finally lower (41 %) than expected (55 %), moreover it presents a spurious oscillation at 4.96 GHz. After analysis of the experimental results, it is concluded that the discrepancy between design and real frequencies is the cause for the low efficiency while the spurious oscillation results from a high gain peak at 4.96 GHz.

physics.acc-ph↗