arXiv Science⌕ Search

arXiv subjects

Jinqiu Xia

Publications and source records attributed to Jinqiu Xia.

2 recordsLinked to original sources

P^2-Gaussian: Prior-Driven and Projection-Guided Gaussian Splatting for Sparse-View Cone-Beam CT Reconstruction

Sparse-view cone-beam computed tomography (CBCT) reconstruction reduces imaging dose and scan time, but severe angular undersampling makes the inverse problem highly ill-posed. Existing 3D Gaussian Splatting (3DGS) methods initialize Gaussian primitives from Feldkamp-Davis-Kress (FDK) reconstructions that are contaminated by streak artifacts. The limited angular coverage also leaves the Gaussian parameters underconstrained, producing needle-like artifacts. We propose P2-Gaussian, a prior-driven and projection-guided 3DGS framework. In this framework, a latent rectified flow model, Sparse2Prior, first restores the artifact-corrupted FDK volume into an anatomical prior in approximately 5 s. Gaussian primitives are then initialized from this prior in a tissue-adaptive manner, which yields a compact representation with 62%-65% fewer optimized primitives than random sampling. During optimization, virtual projections synthesized at intermediate angles between the measured projections are activated in rotation, while measured projections remain dominant in the objective function. Experiments on 5, 10 and 20 measured views showed that the proposed P2-Gaussian achieved the highest PSNR and SSIM among all methods. Compared with the optimization-based Gaussian baseline, our method increases PSNR by 5.98, 4.25 and 2.49 dB and accelerates reconstruction by 2.6-3.0 times. These results indicate that coupling a learned anatomical prior with measurement-constrained Gaussian optimization is effective for sparse-view CBCT reconstruction. Code is publicly available at: https://github.com/Ballbo5354/P-2-Gaussian.

physics.med-ph↗

PND-Net: Physics based Non-local Dual-domain Network for Metal Artifact Reduction

Metal artifacts caused by the presence of metallic implants tremendously degrade the reconstructed computed tomography (CT) image quality, affecting clinical diagnosis or reducing the accuracy of organ delineation and dose calculation in radiotherapy. Recently, deep learning methods in sinogram and image domains have been rapidly applied on metal artifact reduction (MAR) task. The supervised dual-domain methods perform well on synthesized data, while unsupervised methods with unpaired data are more generalized on clinical data. However, most existing methods intend to restore the corrupted sinogram within metal trace, which essentially remove beam hardening artifacts but ignore other components of metal artifacts, such as scatter, non-linear partial volume effect and noise. In this paper, we mathematically derive a physical property of metal artifacts which is verified via Monte Carlo (MC) simulation and propose a novel physics based non-local dual-domain network (PND-Net) for MAR in CT imaging. Specifically, we design a novel non-local sinogram decomposition network (NSD-Net) to acquire the weighted artifact component, and an image restoration network (IR-Net) is proposed to reduce the residual and secondary artifacts in the image domain. To facilitate the generalization and robustness of our method on clinical CT images, we employ a trainable fusion network (F-Net) in the artifact synthesis path to achieve unpaired learning. Furthermore, we design an internal consistency loss to ensure the integrity of anatomical structures in the image domain, and introduce the linear interpolation sinogram as prior knowledge to guide sinogram decomposition. Extensive experiments on simulation and clinical data demonstrate that our method outperforms the state-of-the-art MAR methods.

physics.med-ph↗