arXiv Science⌕ Search

arXiv subjects

Jessica Kächele

Publications and source records attributed to Jessica Kächele.

5 recordsLinked to original sources

Dataset Collections: Challenges of Large-Scale Data Aggregation in 3D Medical Image Datasets

The development of deep learning-based medical AI depends on high-quality annotated data. Yet, dataset creation remains constrained by the need for expert radiologist annotations, limiting curated datasets to relatively small cohorts. To overcome this limitation, recent efforts increasingly aggregate disparate public datasets into large-scale dataset collections. However, combining datasets at scale often obscures data provenance, introducing substantial risks of reuse propagation, unintended leakage, bias amplification and distorted data distributions. In this work, we study these problems on a massive collection of 565k 3D radiological images across 1034 public datasets and provide practical resources to address them. Firstly, we formalize dataset collections as a distinct paradigm in medical image analysis and characterize their structural challenges, including reuse propagation, duplication, and provenance fragmentation. Secondly, we perform a large-scale empirical study of duplication on this collection and demonstrate extensive exact and near-duplicate reuse across public datasets via perceptual hashing and manual tracing, identifying a lower bound of 118k duplicate pairs. We make the perceptual hashes publicly accessible for comparison through our website, providing researchers with a standardized reference for identifying potential overlaps and shared provenance. Thirdly, since hashing alone cannot detect all duplicates, we introduce MAP (Metadata for Aggregation and Provenance), a lightweight, portable metadata profile for documenting provenance, known overlaps, and deduplication decisions in dataset collections. Our contributions help dataset collections shift from coarse aggregations to reliable and provenance-aware data scaling mechanisms in medical image analysis. A web tool supporting our work is available at https://mic-dct.dkfz.de/.

eess.IV↗

nnFoundation: 3D Foundation Models for Radiology

Radiological artificial intelligence has advanced rapidly, yet most systems remain narrowly task-specific, data-intensive, and fragile under domain shift. Foundation models promise more transferable and data-efficient solutions, but existing approaches are limited in scale, evaluated narrowly, and often assume that a single pretrained model can support diverse downstream tasks. Here we present nnFoundation, complementary convolutional and transformer-based 3D radiological foundation models. Developed within the Human Radiome Project (THRP), nnFoundation is trained on 2.1 million CT, MRI, and PET image volumes from 125 institutional and public datasets. We evaluate them across 108 tasks spanning segmentation, detection, classification, report generation, and image retrieval, including evaluations under domain shift, by external partners and in low-data and low-compute regimes. Across all task types, our convolution- and transformer-based nnFoundation models consistently outperform both prior 3D foundation models and training from scratch, establishing state-of-the-art performance for radiological imaging. However, performance follows a consistent task-dependent structure: the convolutional nnFoundation model dominates spatially localized tasks, whereas the transformer-based nnFoundation model excels in tasks requiring global semantic reasoning and in frozen-feature settings. Dynamically aligning the foundation model topology with the dataset characteristics post-hoc further improves transfer across heterogeneous 3D settings. These results show that transferable 3D radiological performance is governed not by a single universal model, but by the interplay of scalable pretraining, complementary architectures, and dataset-aware adaptation. We release nnFoundation models integrated into nnU-Net and nnDetection, enabling immediate application across established radiology workflows.

cs.CV↗

The MAMA-MIA Challenge: Advancing Generalizability and Fairness in Breast MRI Tumor Segmentation and Treatment Response Prediction

Breast cancer is the most frequently diagnosed malignancy among women worldwide and a leading cause of cancer-related mortality. Dynamic contrast-enhanced magnetic resonance imaging plays a central role in tumor characterization and treatment monitoring, particularly in patients receiving neoadjuvant chemotherapy. However, existing artificial intelligence models for breast magnetic resonance imaging are typically developed and evaluated using heterogeneous datasets, study populations, and assessment protocols, making direct comparison difficult and limiting understanding of model robustness across institutions and clinically relevant patient subgroups. The MAMA-MIA Challenge was designed to address these challenges by providing a standardized benchmark for the joint evaluation of primary tumor segmentation and prediction of pathologic complete response using pre-treatment magnetic resonance imaging only. The training cohort comprised 1,506 patients from multiple institutions in the United States, while evaluation was conducted on an external test set of 574 patients from three independent European centers to assess cross-continental and cross-institutional generalization. A unified scoring framework combined predictive performance with subgroup consistency across age, menopausal status, and breast density. Twenty-six international teams participated in the final evaluation phase. Results demonstrate substantial performance variability under a common external evaluation framework and reveal trade-offs between overall accuracy and subgroup fairness. The challenge provides standardized datasets, evaluation protocols, and public resources to promote the development of robust and equitable artificial intelligence systems for breast cancer imaging.

cs.CV↗

Deep Learning for Retinal Degeneration Assessment: A Comprehensive Analysis of the MARIO Challenge

The MARIO challenge, held at MICCAI 2024, focused on advancing the automated detection and monitoring of age-related macular degeneration (AMD) through the analysis of optical coherence tomography (OCT) images. Designed to evaluate algorithmic performance in detecting neovascular activity changes within AMD, the challenge incorporated unique multi-modal datasets. The primary dataset, sourced from Brest, France, was used by participating teams to train and test their models. The final ranking was determined based on performance on this dataset. An auxiliary dataset from Algeria was used post-challenge to evaluate population and device shifts from submitted solutions. Two tasks were involved in the MARIO challenge. The first one was the classification of evolution between two consecutive 2D OCT B-scans. The second one was the prediction of future AMD evolution over three months for patients undergoing anti-vascular endothelial growth factor (VEGF) therapy. Thirty-five teams participated, with the top 12 finalists presenting their methods. This paper outlines the challenge's structure, tasks, data characteristics, and winning methodologies, setting a benchmark for AMD monitoring using OCT, infrared imaging, and clinical data (such as the number of visits, age, gender, etc.). The results of this challenge indicate that artificial intelligence (AI) performs as well as a physician in measuring AMD progression (Task 1) but is not yet able of predicting future evolution (Task 2).

cs.CV↗

The Missing Piece: A Case for Pre-Training in 3D Medical Object Detection

Large-scale pre-training holds the promise to advance 3D medical object detection, a crucial component of accurate computer-aided diagnosis. Yet, it remains underexplored compared to segmentation, where pre-training has already demonstrated significant benefits. Existing pre-training approaches for 3D object detection rely on 2D medical data or natural image pre-training, failing to fully leverage 3D volumetric information. In this work, we present the first systematic study of how existing pre-training methods can be integrated into state-of-the-art detection architectures, covering both CNNs and Transformers. Our results show that pre-training consistently improves detection performance across various tasks and datasets. Notably, reconstruction-based self-supervised pre-training outperforms supervised pre-training, while contrastive pre-training provides no clear benefit for 3D medical object detection. Our code is publicly available at: https://github.com/MIC-DKFZ/nnDetection-finetuning.

eess.IV↗