arXiv ScienceSearch

arXiv subjects

Jaison Lee

Publications and source records attributed to Jaison Lee.

8 recordsLinked to original sources

Development and Initial Performance of an Upgraded NaI(Tl) Crystal Encapsulation for COSINE-100U

The COSINE-100 experiment was designed to test the DAMA/LIBRA annual-modulation claim using low-background NaI(Tl) detectors. For the COSINE-100U upgrade, we developed a new crystal-encapsulation system to increase light-collection efficiency while preserving long-term detector stability, thereby improving sensitivity to low-mass dark matter. The upgraded design eliminates the quartz optical windows used in COSINE-100 and directly couples the photomultiplier tubes (PMTs) to the crystal end faces through 2-mm-thick silicone optical pads, thereby reducing the number of optical interfaces. For the larger crystals, the crystal edges were beveled to guide scintillation light more efficiently onto 3-inch high-quantum-efficiency PMTs. The performance study uses 2462~h (102.6~days) of room-temperature COSINE-100U data and, for direct background comparisons, reference COSINE-100 data acquired near the end of operation. 698~h (29.1~days) of COSINE-100 data acquired near the end of operation in March 2023. All eight crystals showed higher light yields than in COSINE-100, with values ranging from 15.8 to 27.7~p.e./keV; six crystals exceeded 20~p.e./keV. The measured bulk-$\alpha$ rates were lower than the COSINE-100 values and consistent with the expected time evolution of internal $^{210}$Pb, while the 1--2-MeV surface-$\alpha$ rates were substantially reduced. The upgrade also restored two crystals that had previously been excluded from the COSINE-100 physics analysis because of poor optical performance. Independent validation tests demonstrated that the encapsulation remains mechanically robust and optically stable during long-term immersion in liquid scintillator at low temperature. This paper presents the encapsulation design, the room-temperature detector performance, and the reduction in surface-related backgrounds achieved at the Yemilab facility.

physics.ins-det

Performance study of 4-MU-loaded water for Cherenkov light detection

We report on R&D study to improve the photon detection efficiency of water Cherenkov detectors by doping ultra-pure water with 4-methylumbelliferone (4-MU), a wavelength shifting additive. Cherenkov light yields from cosmic-ray muons were measured for various 4-MU concentrations and compared with those from pure water. At a concentration of 1 ppm, the detected light yield increased by approximately a factor of three. This enhancement can be attributed to wavelength shifting and improved photon collection efficiency. No noticeable degradation in optical transparency was observed across the tested concentrations of 0.5 and 1 ppm with different concentration of ethanol. These results suggest that 4-MU is a promising additive for improving the performance of water Cherenkov detectors.

physics.ins-det

New Constraints on Axion-Like Particles with the NEON Detector at a Nuclear Reactor

We report new constraints on axion-like particles (ALPs) using data from the NEON experiment, which features a 16.7 kg of NaI(Tl) target located 23.7 meters from a 2.8 GW thermal power nuclear reactor. Analyzing a total exposure of 3063 kg$\cdot$days, with 1596 kg$\cdot$days during reactor-on and 1467 kg$\cdot$days during reactor-off periods, we compared energy spectra to search for ALP-induced signals. No significant signal was observed, enabling us to set exclusion limits at the 95\% confidence level. These limits probe previously unexplored regions of the ALP parameter space, particularly for axion mass ($m_a$) near $1$ MeV/c$^2$. For ALP-photon coupling (${g_{a\gamma}}$), limits reach as low as 6.24$\times$ 10$^{-6}$ GeV$^{-1}$ at $m_a$ = 3.0 MeV/c$^2$, while for ALP-electron coupling (${g_{ae}}$), limits reach 4.95$\times$ 10$^{-8}$ at $m_a$ = 1.02 MeV/c$^2$. This work demonstrates the potential for future reactor experiments to probe unexplored ALP parameter space.

hep-ex

Radon Concentration Measurement with a High-Sensitivity Radon Detector at the Yemilab

The radiation emitted from radon is a critical background in rare event search experiments conducted at the Yemi Underground Laboratory (Yemilab) in Jeongseon, Korea. A Radon Reduction System(RRS) has been developed and installed in Yemilab to reduce radon concentration in the air. The RRS primarily provides a purified air of 50 m3/h to the cleanroom used to assemble crystal detectors in the AMoRE, a neutrinoless double beta decay search experiment. RRS can reduce the radon level by a factor of 300, so a high-sensitivity radon detector was required. A highly sensitive radon detector was constructed using a 70 L chamber with a large PIN photodiode to measure radon concentration in the purified air. The radon detector shows an excellent resolution of 72 keV (FWHM) for 6.003 MeV alphas from 218Po decay and a sensitivity down to 23.8 +- 2.1 mBq/m3 with a boil-off N2 gas sample. The radon concentration level from the RRS measured by the radon detector was below 0.29 Bq/m3 with a reduction factor of about 300.

physics.ins-det

An experiment to search for dark matter interactions using sodium iodide detectors

Observations of galaxies and primordial radiation suggest that the Universe is made mostly of non-luminous dark matter. Several types of new fundamental particles have been proposed as candidates for dark matter such as weakly interacting massive particles (WIMPs) but no definitive signal has been seen despite concerted efforts by many collaborations. One exception is the much-debated claim by the DAMA collaboration of a statistically significant annual modulation in the event rate of their experiment with a period and phase consistent with that expected from WIMP dark matter. Several groups have been working to develop experiments with the aim of reproducing DAMA's results using the same target medium. Here we report results from the initial operation of the COSINE-100 experiment. COSINE-100 uses sodium iodide as the target medium-the same medium as DAMA-and is designed to carry out a model-independent test of DAMA's claim. Initial data based on the first 59.5 days indicate that there is no excess of events over the expected background, confirming that DAMA's annual modulation signal is in severe tension with results from other experiments under the assumption of dark matter having spin independent interactions and the Standard Halo Model. COSINE-100 is now taking data to study the presence of dark matter-induced annual modulation in the event rate of the sodium iodide detectors.

astro-ph.IM

Sterile neutrino search at NEOS Experiment

An experiment to search for light sterile neutrinos was conducted at a reactor with a thermal power of 2.8 GW located at the Hanbit nuclear power complex. The search was done with a detector consisting of a ton of Gd-loaded liquid scintillator in a tendon gallery approximately 24 m from the reactor core. The measured antineutrino event rate is 1976 per day with a signal to background ratio of about 22. The shape of the antineutrino energy spectrum obtained from eight-month data-taking period is compared with a hypothesis of oscillations due to active-sterile antineutrino mixing. It is found to be consistent with no oscillation. An excess around 5 MeV prompt energy range is observed as seen in existing longer baseline experiments. The parameter space of $\sin^{2}2θ_{14}$ down below 0.1 for $Δm^{2}_{41}$ ranging from 0.2 eV$^{2}$ to 2.3 eV$^{2}$ and the optimum point for the previously reported reactor antineutrino anomaly are excluded with a confidence level higher than 90%.

hep-ex

Measurement of Fast Neutron Rate for NEOS Experiment

The fast neutron rate is measured at the site of NEOS experiment, a short baseline neutrino experiment located in a tendon gallery of a commercial nuclear power plant, using a 0.78-liter liquid scintillator detector. A pulse shape discrimination technique is used to identify neutron signals. The measurements are performed during the nuclear reactor-on and off periods and found to be ~20 per day for both periods. The fast neutron rate is also measured at an overground site with a negligible overburden and is found to be ~100 times higher than that at the NEOS experiment site.

physics.ins-det

Development and Mass Production of a Mixture of LAB- and DIN-based Gadolinium-loaded Liquid Scintillator for the NEOS Short-baseline Neutrino Experiment

A new experiment, which is called as NEOS (NEutrino Oscillation at Short baseline), is proposed on the site of Hanbit reactors at Yonggwang, South Korea, to investigate a reactor antineutrino anomaly. A homogeneous NEOS detector having a 1000-L target volume has been constructed and deployed at the tendon gallery ~25 m away from the reactor core. A linear alkylbenzene (LAB) is used as a main base solvent of the NEOS detector. Furthermore, a di-isopropylnaphthalene (DIN) is added to improve the light output and pulse shape discrimination (PSD) ability. The ratio of LAB to DIN is 90:10. PPO (3 g/L) and bis-MSB (30 mg/L) are dissolved to formulate the mixture of LAB- and DIN-based liquid scintillator (LS). Then, ~0.5% gadolinium (Gd) is loaded into the LS by using the solvent-solvent extraction technique. In this paper, we report the characteristics of Gd-loaded LS (GdLS) for the NEOS detector and the handling during mass production.

physics.ins-det