arXiv ScienceSearch

arXiv subjects

J. Tojo

Publications and source records attributed to J. Tojo.

7 recordsLinked to original sources

Acceleration of positive muons by a radio-frequency cavity

Acceleration of positive muons from thermal energy to $100~$keV has been demonstrated. Thermal muons were generated by resonant multi-photon ionization of muonium atoms emitted from a sheet of laser-ablated aerogel. The thermal muons were first electrostatically accelerated to $5.7~$keV, followed by further acceleration to 100 keV using a radio-frequency quadrupole. The transverse normalized emittance of the accelerated muons in the horizontal and vertical planes were $0.85 \pm 0.25 ~\rm{(stat.)}~^{+0.22}_{-0.13} ~\rm{(syst.)}~\pi~$mm$\cdot$mrad and $0.32\pm 0.03~\rm{(stat.)} ^{+0.05}_{-0.02} ~\rm{(syst.)}~\pi~$mm$\cdot$mrad, respectively. The measured emittance values demonstrated phase space reduction by a factor of $2.0\times 10^2$ (horizontal) and $4.1\times 10^2$ (vertical) allowing good acceleration efficiency. These results pave the way to realize the first-ever muon accelerator for a variety of applications in particle physics, material science, and other fields.

physics.acc-ph

Rabi-Oscillation Spectroscopy of the Hyperfine Structure of Muonium Atoms

As a new method to determine the resonance frequency, Rabi-oscillation spectroscopy has been developed. In contrast to the conventional spectroscopy which draws the resonance curve, Rabi-oscillation spectroscopy fits the time evolution of the Rabi oscillation. By selecting the optimized frequency, it is shown that the precision is twice as good as the conventional spectroscopy with a frequency sweep. Furthermore, the data under different conditions can be treated in a unified manner, allowing more efficient measurements for systems consisting of a limited number of short-lived particles produced by accelerators such as muons. We have developed a fitting function that takes into account the spatial distribution of muonium and the spatial distribution of the microwave intensity to apply the new method to ground-state muonium hyperfine structure measurements at zero field. This was applied to the actual measurement data and the resonance frequencies were determined under various conditions. The result of our analysis gives $\nu_{\rm HFS}=4\ 463\ 301.61 \pm 0.71\ {\rm kHz}$, which is the world's highest precision under zero field conditions.

hep-ex

Performance evaluation of a silicon strip detector for positrons/electrons from a pulsed a muon beam

A high-intensity pulsed muon beam is becoming available at the at the Japan Proton Accelerator Research Complex (J-PARC). Many experiments to study fundamental physics using this high-intensity muon beam are proposed. An experiment to measure the muon magnetic moment anomaly ($g-2$) and the muon electric dipole moment (EDM) is one of these experiments and it requires a tracking detector for positrons from muon decay. Fine segmentation is required in a detector to tolerate the high rate of positrons. The time resolution is required to be much better than the muon anomalous spin precession period while a buffer depth of a front-end electronics needs to be much longer than the accelerated muon lifetime. Requirements of this detector also meet requirements of a measurement of the muonium hyperfine structure interval at the J-PARC and another experiment to measure the proton charge radius at Tohoku University. We have developed a single-sided silicon strip sensor with a 190 $\mu$m pitch, a front-end electronics with a sampling rate of 200 MHz and a buffer memory depth of 8192, and a data acquisition system based on DAQ-Middleware for the J-PARC muon $g-2$/EDM experiment. We have fabricated detector modules consisting of this sensor and the front-end electronics. Performance of fabricated detector modules was evaluated at a laboratory and a beam test using the positron beam at Tohoku University. The detector is confirmed to satisfy all requirements of the experiments except for the time walk, which will be solved by the next version of a front-end electronics.

physics.ins-det

A New Approach for Measuring the Muon Anomalous Magnetic Moment and Electric Dipole Moment

This paper introduces a new approach to measure the muon magnetic moment anomaly $a_{\mu} = (g-2)/2$, and the muon electric dipole moment (EDM) $d_{\mu}$ at the J-PARC muon facility. The goal of our experiment is to measure $a_{\mu}$ and $d_{\mu}$ using an independent method with a factor of 10 lower muon momentum, and a factor of 20 smaller diameter storage-ring solenoid compared with previous and ongoing muon $g-2$ experiments with unprecedented quality of the storage magnetic field. Additional significant differences from the present experimental method include a factor of 1,000 smaller transverse emittance of the muon beam (reaccelerated thermal muon beam), its efficient vertical injection into the solenoid, and tracking each decay positron from muon decay to obtain its momentum vector. The precision goal for $a_{\mu}$ is statistical uncertainty of 450 part per billion (ppb), similar to the present experimental uncertainty, and a systematic uncertainty less than 70 ppb. The goal for EDM is a sensitivity of $1.5\times 10^{-21}~e\cdot\mbox{cm}$.

physics.ins-det

Radiation Damage Study for PHENIX Silicon Stripixel Sensors

Silicon stripixel sensors which were developed at BNL will be installed as part of the RHIC-PHENIX silicon vertex tracker (VTX). RHIC II operations provide luminosity up to 2x10^32 /cm2/s so the silicon stripixel sensors will be exposed to a significant amount of radiation. The most problematic radiation effect for VTX is the increase of leakage current, which degrades the signal to noise ratio and may saturate the readout electronics. We studied the radiation damage using the same diodes as CERN-RD48. First, the proportionality between the irradiation fluence and the increase of leakage current of CERN-RD48 was reproduced. Then beam experiments with stripixel sensor were done in which leakage current was found to increase in the same way as that of thereference diode. A stripixel sensor was also irradiated at the PHENIX interaction region (IR) during the 2006 run. We found the same relation between the integrated luminosity and determined fluence from increase of leakage current. The expected fluence is 3-6x10^12 Neq/cm2 (1 MeV neutron equivalent) in RHIC II operations for 10 years. Due to this expected exposure, setting the operating temperature in PHENIX to T< 0 deg. C to suppress leakage current is needed to avoid saturation of preamplifiers.

nucl-ex

Single Transverse-Spin Asymmetry in Very Forward and Very Backward Neutral Particle Production for Polarized Proton Collisions at sqrt{s} = 200 GeV

In the 2001-2002 running period of the Relativistic Heavy Ion Collider (RHIC), transversely polarized protons were accelerated to 100 GeV for the first time, with collisions at sqrt{s} = 200 GeV. We present results from this run for single transverse spin asymmetries for inclusive production of neutral pions, photons and neutrons of the energy region 20 - 100 GeV for forward and backward production for angles between 0.3 mrad and 2.2 mrad with respect to the polarized proton direction. An asymmetry of A_N = (-0.090 +- 0.006 +- 0.009) x (1.0^{+0.47}_{-0.24}) was observed for forward neutron production, where the errors are statistical and systematic, and the scale error is from the beam polarization uncertainty. The forward photon and pi^0, and backward neutron, photon, and pi^0 asymmetries were consistent with zero. The large neutron asymmetry indicates a strong interference between a spin-flip amplitude, such as one pion exchange which dominates lower energy neutron production, and remaining spin non-flip amplitudes such as Reggeon exchange.

hep-ex

Measurement of Analyzing Power for Proton-Carbon Elastic Scattering in the Coulomb-Nuclear Interference Region with a 22-GeV/c Polarized Proton Beam

The analyzing power for proton-carbon elastic scattering in the coulomb-nuclear interference region of momentum transfer, $9.0\times10^{-3}<-t<4.1\times10^{-2}$ (GeV/$c)^{2}$, was measured with a 21.7 GeV/$c$ polarized proton beam at the Alternating Gradient Synchrotron of Brookhaven National Laboratory. The ratio of hadronic spin-flip to non-flip amplitude, $r_5$, was obtained from the analyzing power to be $\text{Re} r_5=0.088\pm 0.058$ and $\text{Im} r_5=-0.161\pm 0.226$.

hep-ex