Astroparticle Physics with a Customized Low-Background Broad Energy Germanium Detector

The MAJORANA Collaboration is building the MAJORANA DEMONSTRATOR, a 60 kg array of high purity germanium detectors housed in an ultra-low background shield at the Sanford Underground Laboratory in Lead, SD. The MAJORANA DEMONSTRATOR will search for neutrinoless double-beta decay of 76Ge while demonstrating the feasibility of a tonne-scale experiment. It may also carry out a dark matter search in the 1-10 GeV/c^2 mass range. We have found that customized Broad Energy Germanium (BEGe) detectors produced by Canberra have several desirable features for a neutrinoless double-beta decay experiment, including low electronic noise, excellent pulse shape analysis capabilities, and simple fabrication. We have deployed a customized BEGe, the MAJORANA Low-Background BEGe at Kimballton (MALBEK), in a low-background cryostat and shield at the Kimballton Underground Research Facility in Virginia. This paper will focus on the detector characteristics and measurements that can be performed with such a radiation detector in a low-background environment.

nucl-ex↗

Comments on arXiv:1006.0972 "XENON10/100 dark matter constraints in comparison with CoGeNT and DAMA: examining the Leff dependence"

Savage et al. have recently put forward the claim that results from the XENON10 experiment are incompatible with the totality of both DAMA/LIBRA and CoGeNT experimental regions. In this brief note the source of this erroneous conclusion is identified in a misinterpretation of the XENON10 efficiency in the detection of S1 light from low-energy nuclear recoils.

astro-ph.CO↗

Response to arXiv:1005.2615

Brief response to a Reply [arXiv:1005.2615] on our Comments [arXiv:1005.0838] on XENON100 recent results [arXiv:1005.0380].

astro-ph.CO↗

Comments on "First Dark Matter Results from the XENON100 Experiment"

The XENON100 collaboration has recently released new dark matter limits, placing particular emphasis on their impact on searches known to be sensitive to light-mass (below 10 GeV/c^2) Weakly Interacting Massive Particles (WIMPs), such as DAMA and CoGeNT. We describe here several sources of uncertainty and bias in their analysis that make their new claimed sensitivity presently untenable. In particular, we point out additional work in this field and simple kinematic arguments that indicate that liquid xenon (LXe) may be a relatively insensitive detection medium for the recoil energies (few keV_r) expected from such low mass WIMPs.

astro-ph.CO↗

Results from a Search for Light-Mass Dark Matter with a P-type Point Contact Germanium Detector

We report on several features present in the energy spectrum from an ultra low-noise germanium detector operated at 2,100 m.w.e. By implementing a new technique able to reject surface events, a number of cosmogenic peaks can be observed for the first time. We discuss several possible causes for an irreducible excess of bulk-like events below 3 keVee, including a dark matter candidate common to the DAMA/LIBRA annual modulation effect, the hint of a signal in CDMS, and phenomenological predictions. Improved constraints are placed on a cosmological origin for the DAMA/LIBRA effect.

astro-ph.CO↗

Search for solar axion emission from 7Li and D(p,gamma)3He nuclear decays with the CAST gamma-ray calorimeter

We present the results of a search for a high-energy axion emission signal from 7Li (0.478 MeV) and D(p,gamma)3He (5.5 MeV) nuclear transitions using a low-background gamma-ray calorimeter during Phase I of the CAST experiment. These so-called "hadronic axions" could provide a solution to the long-standing strong-CP problem and can be emitted from the solar core from nuclear M1 transitions. This is the first such search for high-energy pseudoscalar bosons with couplings to nucleons conducted using a helioscope approach. No excess signal above background was found.

hep-ex↗

Search for 14.4 keV solar axions emitted in the M1-transition of 57Fe nuclei with CAST

We have searched for 14.4 keV solar axions or more general axion-like particles (ALPs), that may be emitted in the M1 nuclear transition of 57Fe, by using the axion-to-photon conversion in the CERN Axion Solar Telescope (CAST) with evacuated magnet bores (Phase I). From the absence of excess of the monoenergetic X-rays when the magnet was pointing to the Sun, we set model-independent constraints on the coupling constants of pseudoscalar particles that couple to two photons and to a nucleon g_{aγ} |-1.19 g_{aN}^{0}+g_{aN}^{3}|<1.36\times 10^{-16} GeV^{-1} for m_{a}<0.03 eV at the 95% confidence level.

hep-ex↗

Probing eV-scale axions with CAST

We have searched for solar axions or other pseudoscalar particles that couple to two photons by using the CERN Axion Solar Telescope (CAST) setup. Whereas we previously have reported results from CAST with evacuated magnet bores (Phase I), setting limits on lower mass axions, here we report results from CAST where the magnet bores were filled with \hefour gas (Phase II) of variable pressure. The introduction of gas generated a refractive photon mass $m_γ$, thereby achieving the maximum possible conversion rate for those axion masses \ma that match $m_γ$. With 160 different pressure settings we have scanned \ma up to about 0.4 eV, taking approximately 2 h of data for each setting. From the absence of excess X-rays when the magnet was pointing to the Sun, we set a typical upper limit on the axion-photon coupling of $\gag\lesssim 2.17\times 10^{-10} {\rm GeV}^{-1}$ at 95% CL for $\ma \lesssim 0.4$ eV, the exact result depending on the pressure setting. The excluded parameter range covers realistic axion models with a Peccei-Quinn scale in the neighborhood of $f_{\rm a}\sim10^{7}$ GeV. Currently in the second part of CAST Phase II, we are searching for axions with masses up to about 1.2 eV using \hethree as a buffer gas.

hep-ex↗

Solar axion search with the CAST experiment

The CAST (CERN Axion Solar Telescope) experiment is searching for solar axions by their conversion into photons inside the magnet pipe of an LHC dipole. The analysis of the data recorded during the first phase of the experiment with vacuum in the magnet pipes has resulted in the most restrictive experimental limit on the coupling constant of axions to photons. In the second phase, CAST is operating with a buffer gas inside the magnet pipes in order to extent the sensitivity of the experiment to higher axion masses. We will present the first results on the $^{4}{\rm He}$ data taking as well as the system upgrades that have been operated in the last year in order to adapt the experiment for the $^{3}{\rm He}$ data taking. Expected sensitivities on the coupling constant of axions to photons will be given for the recent $^{3}{\rm He}$ run just started in March 2008.

hep-ex↗

Search for low Energy solar Axions with CAST

We have started the development of a detector system, sensitive to single photons in the eV energy range, to be suitably coupled to one of the CAST magnet ports. This system should open to CAST a window on possible detection of low energy Axion Like Particles emitted by the sun. Preliminary tests have involved a cooled photomultiplier tube coupled to the CAST magnet via a Galileian telescope and a switched 40 m long optical fiber. This system has reached the limit background level of the detector alone in ideal conditions, and two solar tracking runs have been performed with it at CAST. Such a measurement has never been done before with an axion helioscope. We will present results from these runs and briefly discuss future detector developments.

hep-ex↗

Additional Comments on "New Limits on Spin-Independent Couplings of Low-Mass WIMP Dark Matter with a Germanium Detector at a Threshold of 200 eV"

In a previous comment (arXiv:0806.1341v1) we criticized purely technical aspects of arXiv:0712.1645 but pointed out that many other inconsistencies were readily apparent. In view of the imminent posting of another version of arXiv:0712.1645, still containing these issues, we would like to offer with this additional note a critical guide to the methodology followed by the TEXONO collaboration, in their effort to extract dark matter limits from a spectral region completely dominated by electronic noise. We find that systematics have been neglected through a combination of erroneous assumptions and failure to explore all of their possible sources.

hep-ex↗

Experimental constraints on a dark matter origin for the DAMA annual modulation effect

A claim for evidence of dark matter interactions in the DAMA experiment has been recently reinforced. We employ a new type of germanium detector to conclusively rule out a standard isothermal galactic halo of Weakly Interacting Massive Particles (WIMPs) as the explanation for the annual modulation effect leading to the claim. Bounds are similarly imposed on a suggestion that dark pseudoscalars mightlead to the effect. We describe the sensitivity to light dark matter particles achievable with our device, in particular to Next-to-Minimal Supersymmetric Model candidates.

astro-ph↗

Improved Spin-Dependent WIMP Limits from a Bubble Chamber

Bubble Chambers provided the dominant particle detection technology in accelerator experiments for several decades, eventually falling into disuse with the advent of other techniques. We report here on the first period of operation of an ultra-clean, room-temperature bubble chamber containing 1.5 kg of superheated CF$_{3}$I, a target maximally sensitive to spin-dependent and -independent Weakly Interacting Massive Particle (WIMP) couplings. An exposure in excess of 250 kg-days is obtained, with a live-time fraction reaching 80%. This illustrates the ability to employ bubble chambers in a new realm, the search for dark matter particles. Improved limits on the spin-dependent WIMP-proton scattering cross section are extracted from this first period. An extreme intrinsic insensitivity to the backgrounds commonly limiting these experiments (a rejection factor for photon-induced electrons of $\sim10^{-10}$) has been measured in operating conditions leading to the detection of low-energy nuclear recoils such as those expected from WIMPs.

astro-ph↗

WIMP identification through a combined measurement of axial and scalar couplings

We study the prospects for detecting Weakly Interacting Massive Particles (WIMPs), in a number of phenomenological scenarios, with a detector composed of a target simultaneously sensitive to both spin-dependent and spin-independent couplings, as is the case of COUPP (Chicagoland Observatory for Underground Particle Physics). First, we show that sensitivity to both couplings optimizes chances of initial WIMP detection. Second, we demonstrate that in case of detection, comparison of the signal on two complementary targets, such as in COUPP CF3I and C4F10 bubble chambers, allows a significantly more precise determination of the dark matter axial and scalar couplings. This strategy would provide crucial information on the nature of the WIMPs, and possibly allow discrimination between neutralino and Kaluza-Klein dark matter.

astro-ph↗

Large-Mass Ultra-Low Noise Germanium Detectors: Performance and Applications in Neutrino and Astroparticle Physics

A new type of radiation detector, a p-type modified electrode germanium diode, is presented. The prototype displays, for the first time, a combination of features (mass, energy threshold and background expectation) required for a measurement of coherent neutrino-nucleus scattering in a nuclear reactor experiment. The device hybridizes the mass and energy resolution of a conventional HPGe coaxial gamma spectrometer with the low electronic noise and threshold of a small x-ray semiconductor detector, also displaying an intrinsic ability to distinguish multiple from single-site particle interactions. The present performance of the prototype and possible further improvements are discussed, as well as other applications for this new type of device in neutrino and astroparticle physics (double-beta decay, neutrino magnetic moment and WIMP searches).

nucl-ex↗

Design and Characterization of a Neutron Calibration Facility for the Study of sub-keV Nuclear Recoils

As part of an experimental effort to demonstrate sensitivity in a large-mass detector to the ultra-low energy recoils expected from coherent neutrino-nucleus elastic scattering, we have designed and built a highly monochromatic 24 keV neutron beam at the Kansas State University Triga Mark-II reactor. The beam characteristics were chosen so as to mimic the soft recoil energies expected from reactor antineutrinos in a variety of targets, allowing to understand the response of dedicated detector technologies in this yet unexplored sub-keV recoil range. A full characterization of the beam properties (intensity, monochromaticity, contaminations, beam profile) is presented, together with first tests of the calibration setup using proton recoils in organic scintillator.

nucl-ex↗