arXiv ScienceSearch

arXiv subjects

J. Colin

Publications and source records attributed to J. Colin.

13 recordsLinked to original sources

The dipole anisotropy of AllWISE galaxies

We determine the dipole in the WISE galaxy catalogue. After reducing star contamination to <0.1% by rejecting sources with high apparent motion and those close to the Galactic plane, we eliminate low redshift sources to suppress the non-kinematic, clustering dipole. We remove sources within {\pm}5{\deg} of the super-galactic plane, as well as those within 1'' of 2MRS sources at redshift z < 0.03. We enforce cuts on the source angular extent to preferentially select distant ones. As we progress along these steps, the dipole converges in direction to within 5{\deg} of the CMB dipole and its magnitude also progressively reduces but stabilises at {\sim}0.012, corresponding to a velocity >1000 km/s if it is solely of kinematic origin. However, previous studies have shown that only {\sim}70% of the velocity of the Local Group as inferred from the CMB dipole is due to sources at z < 0.03. We examine the Dark Sky simulations to quantify the prevalence of such environments and find that <2.1% of Milky Way-like observers in a {\Lambda}CDM universe should observe the bulk flow (> 240 km/s extending to z > 0.03) that we do. We construct mock catalogues in the neighbourhood of such peculiar observers in order to mimic our final galaxy selection and quantify the residual clustering dipole. After subtracting this the remaining dipole is 0.0048 {\pm} 0.0022, corresponding to a velocity of 420 {\pm} 213 km/s which is consistent with the CMB. However the sources (at z > 0.03) of such a large clustering dipole remain to be identified.

astro-ph.CO

High redshift radio galaxies and divergence from the CMB dipole

Previous studies have found our velocity in the rest frame of radio galaxies at high redshift to be substantially larger than that inferred from the CMB temperature dipole anisotropy. We construct a full sky catalogue NVSUMSS, by merging the NVSS and SUMSS catalogues and removing local sources by various means including cross-correlating with the 2MRS catalogue. We take into account both aberration and Doppler boost to deduce our velocity from the hemispherical number count asymmetry, as well as via a 3-dimensional linear estimator. Both the magnitude and direction depend on cuts made to the catalogue, e.g. on the lowest source flux, however these effects are small. With the hemispheric number count asymmetry method we obtain a velocity of 1729 $\pm$ 187 km/s i.e. about 4 times larger than that obtained from the CMB dipole, but close in direction, towards RA=149 $\pm$ 2 degree, DEC = -17 $\pm$ 12 degree. With the 3-dimensional estimator, the derived velocity is 1355 $\pm$ 174 km/s towards RA=141 $\pm$ 11 degree, DEC=-9 $\pm$ 10 degree. We assess the statistical significance of these results by constructing catalogues of random distributions and show that they are at best significant at the $2.81 \sigma$ (99.95% confidence) level.

astro-ph.CO

Characterization and performances of DOSION, a dosimetry equipment dedicated to radiobiology experiments taking place at GANIL

Currently, radiobiology experiments using heavy ions at GANIL(Grand Accelerateur National d Ions Lourds) are conducted under the supervision of the CIMAP (Center for research on Ions, MAterials and Photonics). In this context, a new beam monitoring equipment named DOSION has been developed. It allows to perform measurements of accurate fluence and dose maps in near real time for each biological sample irradiated. In this paper, we present the detection system, its design, performances, calibration protocol and measurements performed during radiobiology experiments. This setup is currently available for any radiobiology experiments if one wishes to correlate one s own sample analysis to state of the art dosimetric references.

physics.med-ph

Simulation study on light ions identification methods for carbon beams from 95 to 400 MeV/A

Monte Carlo simulations have been performed in order to evaluate the efficiencies of several light ions identification techniques. The detection system was composed with layers of scintillating material to measure either the deposited energy or the time-of-flight of ions produced by nuclear reactions between 12C projectiles and a PMMA target. Well known techniques such as (DELTA) E--Range, (DELTA) E--E--ToF and (DELTA)E--E are presented and their particle identification efficiencies are compared one to another regarding the generated charge and mass of the particle to be identified. The simulations allowed to change the beam energy matching the ones proposed in an hadron therapy facility, namely from 95 to 400 MeV/A.

nucl-ex

Characterization and performances of a monitoring ionization chamber dedicated to IBA-universal irradiation head for Pencil Beam Scanning

Every radiotherapy center has to be equipped with real-time beam monitoring devices. In 2008, the medical application group from the Laboratory of Corpuscular Physics (LPC Caen) developed an Ionization Chamber in collaboration with the company IBA (Ion Beam Applications). This monitoring device called IC2/3 was developed to be used in IBAs universal irradiation head for Pencil Beam Scanning (PBS). The objectives presented in this article are to characterize the IC2/3 monitor in the energy and ux ranges used in protontherapy. The equipment has been tested with an IBAs cyclotronable to deliver proton beams from 70 to 230 MeV. This beam monitoring device has been validated and is now installed at the Westdeutsches Protonentherapiezentrum Essen protontherapy center (WPE, Germany). The results obtained in both terms of spatial resolution and dose measurements are at least equal to the initials speci cations needed for PBS purposes. The detector measures the dose with a relative precision better than 1% in the range 0.5 Gy/min to 8 Gy/min while the spatial resolution is higher than 250 m. The technology has been patented and ve IC2/3 chambers were delivered to IBA. Nowadays, IBA produces the IC2/3 beam monitoring device as part of its Proteus 235 product

physics.ins-det

Double di ffential fragmentation cross sections measurements of 95 MeV/u 12C on thin targets for hadrontherapy

During therapeutic treatment with heavy ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, an accurate prediction on the fluences of these secondary fragments is necessary. Nowadays, a very limited set of double di ffential carbon fragmentation cross sections are being measured in the energy range used in hadrontherapy (40 to 400 MeV/u). Therefore, new measurements are performed to determine the double di ffential cross section of carbon on di erent thin targets. This work describes the experimental results of an experiment performed on May 2011 at GANIL. The double di ffential cross sections and the angular distributions of secondary fragments produced in the 12C fragmentation at 95 MeV/u on thin targets (C, CH2, Al, Al2O3, Ti and PMMA) have been measured. The experimental setup will be precisely described, the systematic error study will be explained and all the experimental data will be presented.

nucl-ex

Comparison of two analysis methods for nuclear reaction measurements of 12C +12C interactions at 95 MeV/u for hadrontherapy

During therapeutic treatment with heavier ions like carbon, the beam undergoes nuclear fragmentation and secondary light charged particles, in particular protons and alpha particles, are produced. To estimate the dose deposited into the tumors and the surrounding healthy tissues, the accuracy must be higher than ($\pm$3% and$\pm$1 mm). Therefore, measurements are performed to determine the double differential cross section for different reactions. In this paper, the analysis of data from 12C +12C reactions at 95 MeV/u are presented. The emitted particles are detected with \DeltaEthin-\DeltaEthick-E telescopes made of a stack of two silicon detectors and a CsI crystal. Two different methods are used to identify the particles. One is based on graphical cuts onto the \DeltaE-E maps, the second is based on the so-called KaliVeda method using a functional description of \DeltaE versus E. The results of the two methods will be presented in this paper as well as the comparison between both.

physics.med-ph

High flux polarized gamma rays production: first measurements with a four-mirror cavity at the ATF

The next generation of e+/e- colliders will require a very intense flux of gamma rays to allow high current polarized positrons to be produced. This can be achieved by converting polarized high energy photons in polarized pairs into a target. In that context, an optical system consisting of a laser and a four-mirror passive Fabry-Perot cavity has recently been installed at the Accelerator Test Facility (ATF) at KEK to produce a high flux of polarized gamma rays by inverse Compton scattering. In this contribution, we describe the experimental system and present preliminary results. An ultra-stable four-mirror non planar geometry has been implemented to ensure the polarization of the gamma rays produced. A fiber amplifier is used to inject about 10W in the high finesse cavity with a gain of 1000. A digital feedback system is used to keep the cavity at the length required for the optimal power enhancement. Preliminary measurements show that a flux of about $4\times10^6 \gamma$/s with an average energy of about 24 MeV was generated. Several upgrades currently in progress are also described.

physics.acc-ph

Direct constraint on the distance of y2 Velorum from AMBER/VLTI observations

In this work, we present the first AMBER observations, of the Wolf-Rayet and O (WR+O) star binary system y2 Velorum. The AMBER instrument was used with the telescopes UT2, UT3, and UT4 on baselines ranging from 46m to 85m. It delivered spectrally dispersed visibilities, as well as differential and closure phases, with a resolution R = 1500 in the spectral band 1.95-2.17 micron. We interpret these data in the context of a binary system with unresolved components, neglecting in a first approximation the wind-wind collision zone flux contribution. We show that the AMBER observables result primarily from the contribution of the individual components of the WR+O binary system. We discuss several interpretations of the residuals, and speculate on the detection of an additional continuum component, originating from the free-free emission associated with the wind-wind collision zone (WWCZ), and contributing at most to the observed K-band flux at the 5% level. The expected absolute separation and position angle at the time of observations were 5.1&plusmn;0.9mas and 66&plusmn;15&deg; respectively. However, we infer a separation of 3.62+0.11-0.30 mas and a position angle of 73+9-11&deg;. Our analysis thus implies that the binary system lies at a distance of 368+38-13 pc, in agreement with recent spectrophotometric estimates, but significantly larger than the Hipparcos value of 258+41-31 pc.

astro-ph

Dynamical effects in multifragmentation at intermediate energies

The fragmentation of the quasi-projectile is studied with the INDRA multidetector for different colliding systems and incident energies in the Fermi energy range. Different experimental observations show that a large part of the fragmentation is not compatible with the statistical fragmentation of a fully equilibrated nucleus. The study of internal correlations is a powerful tool, especially to evidence entrance channel effects. These effects have to be included in the theoretical descriptions of nuclear multifragmentation.

nucl-ex

M2000 : an astrometric catalog in the Bordeaux Carte du Ciel zone +11 degrees < {delta} < +18 degrees

During four years, systematic observations have been conducted in drift scan mode with the Bordeaux automated meridian circle in the declination band [+11 ; +18]. The resulting astrometric catalog includes about 2 300 000 stars down to the magnitude limit V_M=16.3. Nearly all stars (96%) have been observed at least 6 times, the catalog being complete down to V_M=15.4. The median internal standard error in position is about 35 mas in the V_M magnitude range [11 ; 15], which degrades to about 50 mas when the faintest stars are considered. M2000 provides also one band photometry with a median internal standard error of 0.04 mag. Comparisons with the Hipparcos and bright part of Tycho-2 catalogs have enabled to estimate external errors in position to be lower than 40 mas. In this zone and at epoch 1998, the faint part of Tycho-2 is found to have an accuracy of 116 mas in alpha instead of 82 mas deduced from the model-based standard errors given in the catalog.

astro-ph

Effect of the intermediate velocity emissions on the quasi-projectile properties for the Ar+Ni system at 95 A.MeV

The quasi-projectile (QP) properties are investigated in the Ar+Ni collisions at 95 A.MeV taking into account the intermediate velocity emission. Indeed, in this reaction, between 52 and 95 A.MeV bombarding energies, the number of particles emitted in the intermediate velocity region is related to the overlap volume between projectile and target. Mean transverse energies of these particles are found particularly high. In this context, the mass of the QP decreases linearly with the impact parameter from peripheral to central collisions whereas its excitation energy increases up to 8 A.MeV. These results are compared to previous analyses assuming a pure binary scenario.

nucl-ex

Hot subdwarf stars - galactic orbits and distribution perpendicular to the plane

The spatial distribution and the population nature of subdwarf B type stars in the galaxy is investigated based on the kinematics of these stars. The orbits of 41 stars have been calculated using a galactic mass model. These are well behaved and 10 stars reach to |z| > 2 kpc. Many orbits are very eccentric, reaching in to just 2 kpc from the galactic centre, or veering out to beyond 20 kpc. None of the stars can be identified uniquely as classical Population II objects. The average eccentricity ECC of the orbits of our sample is 0.24, the average normalised z-extent NZE of the orbits is 0.16, and the asymmetric drift of our sample is -36 km s^-1. The distribution in z shows a relative minimum near z=0 pc and has maxima near z=300 pc. This reflects the smaller probability to find the stars IN the disk than away from the disk.

astro-ph